TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E — Proven and reliable concept — Integral mount design • Small dimensions, low weight — Sturdy construction and solid functionality • Influence of shock and vibration < 1 % at 10 g — Variety of signal ranges • Input e.g. 0 to 20 mA or 4 to 20 mA • Output 0.2 to 1 bar (3 to 15 psi) — Complies with the following directives • EMC directive 2014/30/EU • EC directive for CE declaration of conformity — Wide temperature range • From –40° (optional –55°) to 85 °C (
Abrir o catálogo na página 2
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Change from one to two columns — Concept The TEIP11-PS signal converter converts standard electrical signals, e.g. 4 to 20 mA to 0.2 to 1 bar (3 to 15 psi). It is therefore a connecting link between electrical/electronic and pneumatic systems. The signal conversion process is similar to the patented force balance method. Special features of the TEIP11-PS signal converter are its relatively small dimensions and outstanding operational stability when subject to shock and vibration. The converter can be subjected to...
Abrir o catálogo na página 3
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E ... Designs Field mount housing The field mount housing is suited for installation on-site or in open areas. The housing can be made from plastic with IP rating IP 54, from aluminum with IP rating IP 65 and from stainless steel with IP rating IP 65. The housing is suited for wall mounting and for 2 in pipe mounting. A specially designed signal converter in a plastic housing unit enables the use of combustible gas as a power supply instead of the standard compressed air. Specification Input (electric) Signal range 0...
Abrir o catálogo na página 4
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Transmission data and contributing factors Characteristic curve Linear, direct, or reverse action Characteristic curve deviation < 0.5 % Hysteresis < 0.3 % Dead band < 0.1 % Temperature < 1 % / 10 K within -20 to 85 °C (-4 to 185 °F) < 2 % / 10 K within -55 to -20 °C (-67 to -4 °F) Power supply < 0.3 % / 0.1 bar (1.5 psi) change in pressure Mechanical vibration < 1 % to 10 g and 20 to 80 Hz Seismic vibration Meets the requirements of DIN IEC 68-3-3 Class III for strong and strongest earthquakes. Mounting...
Abrir o catálogo na página 5
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E ... Specification Design for rail mounting Material / IP rating IP 20 aluminum housing unit, with plastic cover Mounting Rail mounting: EN 50022 - 35 x 7.5 EN 50035 - G 32 EN 50045 - 15 x 5 Electrical connection 2-pole screw terminal for 2.5 mm2 (14 AWG) Pneumatic connection Vs NPT threaded hole for supply air and output Weight 0.25 kg (0.55 lb) Dimensions Refer to Dimensions on page 10. Design for block mounting Material / IP rating IP 20 aluminum housing unit, with plastic cover Mounting In block format with...
Abrir o catálogo na página 6
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Design for field housing unit (aluminum/stainless steel) Material / IP rating IP 65 aluminum or stainless steel housing unit Surface Aluminum housing, painted with dual component coating, lower section, black, RAL 9005, screw-on cover, Pantone 420, stainless steel housing unit, electrolytically polished Mounting Wall or 2 in pipe mounting With stainless steel mounting bracket (accessory) Electrical connection 2-pole screw terminal for 2.5 mm2 (14 AWG) in the housing, screw connection NPT % in for the cable...
Abrir o catálogo na página 7
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Ex relevant specificationsFlameproof (enclosure), ATEX ‘Ex d' Operation as intrinsically safe equipment Marking Type Examination Test Certificate Type Device class II 2G Ex d IIC T4/T5/T6 Gb DMT 02 ATEX E 121 X DOC. 900771 II 2G EN 60079-0: 2012 (General requirements) EN 60079-1: 2007 (Flameproof enclosure ‘d’) Marking Type Examination Test Certificate Type System bus, computer interfaces Device class Pneumatic data Supply pressure 1.4 bar (20 psi) / Temperature classes for the following versions: TEIP11 Doc....
Abrir o catálogo na página 8
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Special conditions The I/P signal converter TEIP11-PS Doc. 901068 or TEIP11-PS Doc. 901069 must be set up outdoors as a pneumatic power supply when used with combustible gases. The supplied gas must be kept sufficiently free of air and oxygen to prevent a potentially explosive atmosphere from forming. The gas must always be routed to the outside. FM / CSA Intrinsically safe FM FM 'intrinsically safe' (not for metal field housing units) I.S.: CL I/Div 1/Grp A B C D FM 'intrinsically safe' (only for metal field...
Abrir o catálogo na página 9
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E — Dimensions Design for control room housing unit for rail mounting Dimensions in mm (in) 5 Mounting bracket for DIN rail mounting 3 Output Figure 2: Dimensions of control room housing design for rail mounting
Abrir o catálogo na página 10
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E Design for control room housing unit for block mounting Dimensions in mm (in) 5 End panel with central supply air connection 4 Electrical connections Figure 3: Dimensions of control room housing design for block mounting ** Version 0.4 to 1 bar (5.80 to 14.50 psi) *** Length 80 mm (3.15 in) per connection block
Abrir o catálogo na página 11
TEIP11-PS I/P SIGNAL CONVERTER FOR STANDARD SIGNALS | DS/TEIP11-PS-EN REV. E — … Dimensions Design for plastic field housing unit Dimensions in mm (in) 2 Connection only with version for operation with flammable gas for diverting the escaping gas / 6 mm (0.24 in) screw terminal connection Figure 4: Dimensions of plastic field mount housing design
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas