Sodium Monitor Model 8036
1 / 8Páginas

{{requestButtons}}

Excertos do catálogo

Sodium Monitor Model 8036 - 1

Wide measuring range (0.01 gkg > 1 to 10mgkg > ֖1 ) covers all power station applications Full sample temperature compensation ֖maximises measurement accuracy 'Pumpless' liquid handling section low maintenance Automatic range changing ֖switches the current output in steps covering twodecades Simple calibration sequence automatically controlled by the microprocessor >

Abrir o catálogo na página 1
Sodium Monitor Model 8036 - 2

Sodium Monitor Model 8036 > SS/8036_5 The prevention of damage to the boilers on modern powerstations becomes more and more critical as the cost of repairsand out of service plant continually rises. To reduce the effect ofboiler tube corrosion and the formation of scale on the inside of the tubes, the levels of impurities in the various parts of thesteam/water cycle must be carefully monitored.Sodium ions are normally the most abundant species in solutionfound in boiler plant, therefore the measurement of sodiumprovides a valuable indication of the overall purity of the solution.Whilst...

Abrir o catálogo na página 2
Sodium Monitor Model 8036 - 3

Heat exchanger this is used to bring the standard solution close to the temperatureof the sample during calibration. Thermal differences therefore are minimised and calibration times reduced. Pressure relief valve ֖ during a calibration sequence the sample flow to the constanthead unit is stopped. The valve releases the pressure to prevent pressurising the sample line. Solenoid valve > under the control of the microprocessor the valve is used to switchbetween sample in normal running mode and standard solution during a calibration sequence. Constant head unit ֖ > 1 this removes the effect...

Abrir o catálogo na página 3
Sodium Monitor Model 8036 - 5

Sodium concentration gkg > 1 or mgkg > ֖1 Sample mode indicates sample sodium concentration. During calibration indicates either of the two calibration sequences (CA1 or CA2). Calibration concentration displays the values of CA1 (the primary calibration solution) or CA2(the secondary calibration solution) ֖ also indicates when a calibration is in progress and shows if a single or two-point calibration has been initiated.An instantaneous display of concentration during calibration canalso be obtained. Alarm settings displays high or low alarm setting > Calibration fail displays CF following...

Abrir o catálogo na página 5
Sodium Monitor Model 8036 - 6

Ranges Connections to sensor unit 0.01 gkg > 1 to 1mgkg > ֖1 or 0.1 gkg > 1 to 10mgkg > ֖1 internallyselectable Sample inlet:6mm O.D. compression fittingSample drain:10mm flexible, atmospheric drain Sample line material:Stainless steel Electrical:Via gland cable size 7 to 10.5mmMax. core size:Mains 32/0.2mmSignal 24/0.2mm Accuracy Dimensions of transmitter unit 10% of concentration or 0.02 gkg > ֖1 whichever is the greater 300mm wide x 300mm high x 200mm deep Reproducibility Mounting for transmitter unit 5% of concentration at constant temperature 230mm horizontal230mm vertical Response...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos ABB Measurement & Analytics

  1. ProKiln GAC400

    24 Páginas

  2. AV1 and AV2

    24 Páginas

  3. OriMaster FPD500

    24 Páginas

  4. AquaProbe FEA200

    16 Páginas

  5. FTPA2000-HP260

    4 Páginas

  6. 266HSH and 266NSH

    40 Páginas

  7. SCK

    20 Páginas

  8. INDI-BOY DSP

    8 Páginas

  9. 9QGPS4500

    8 Páginas

  10. 9QGPS3100P

    12 Páginas

  11. 9QGPS2960

    12 Páginas

  12. 9QGPS2625

    8 Páginas

  13. MB3600-HP10

    5 Páginas

  14. MB3600-CH10

    8 Páginas

  15. ACF5000

    16 Páginas

  16. Magnos28

    10 Páginas

  17. Dynamic QR Code

    4 Páginas

  18. EL3060

    8 Páginas

  19. HP30

    4 Páginas

  20. Aztec ATS430

    12 Páginas

  21. LMS200

    12 Páginas

  22. PGC5000

    8 Páginas

  23. LGR-ICOS 927S

    4 Páginas

  24. ALSCAN Brochure

    6 Páginas

  25. MR Series

    2 Páginas