Grupo: ABB
Excertos do catálogo

ABB MEASUREMENT & ANALY TICS | DATA SHEET PxS100, PxF100, PxP100, PxD100 Gauge and absolute pressure transmitters
Abrir o catálogo na página 1
— Measurement made easy Engineered solutions for all applications Standard overload resistance Base accuracy • From ± 0.25 % up to ± 0.075 % of calibrated span Span limits • 0,3 – 10000 kPa; 16 inH2O up to 1450 psi • 0,3 – 10000 kPa abs; 30 mmHg up to 1450 psia Proven sensor technology together with state-of-the-art digital technology • Valuable turn down ratio of up to 100:1 Stainless steel housing • Optimized for use in industrial process environments • Extremely robust New touch keypad technology • allows quick and easy local configuration without opening the cover, even in hazardous...
Abrir o catálogo na página 2
— General Description PxS100 Model PxS100 is the compact, reliable, essential pressure transmitter suitable for liquid, gas or steam applications. It is a straightforward and robust device designed for rapid delivery and easy installation and use. Thanks to its rugged design offering high resistance in even the most demanding environments, it is a competitive solution for most applications, including ones in hazardous areas. PxD100 Model PxD100 is the pressure transmitter from the Pxx100 series featuring the S26 diaphragm seal line accessories. While having a compact, sturdy stainless-steel...
Abrir o catálogo na página 3
— Specification - Physical(1) Materials Process isolating diaphragms (2) AISI 316 L ss, Hastelloy C276, Diaflex (antiabrasion), H-Shield (against hydrogen permeation) Process connection (2) AISI 316 L ss Hastelloy C276 (Available on request) Filling fluids (3) Silicone oil, inert fill (fluorocarbon), Mineral oil (FDA approved), Vegetal oil (FDA approved) Mounting bracket AISI 304 ss Sensor housing, electronics housing and cover AISI 316 L ss Filter for atmospheric ventilation • Filter material: polyamide (PA) • Filter housing: plastic (general purpose version), stainless steel (Ex certified...
Abrir o catálogo na página 4
— Functional – specification Range and span limits Sensor code Upper range limit (URL) Lower range limit (LRL) Minimum measuring span Model PGx100 Model PAx100 Gauge Absolute pressure pressure IMPORTANT (NOTE) The lower range limits (LRL) for models PAx100 are 0 absolute for all measuring ranges. Span limits Maximum span = upper range limit (URL) To optimize performance characteristics, it is recommended that you select the transmitter sensor code providing the lowest turn down ratio. TURNDOWN = Upper range limit / set span Zero suppression and elevation Zero and span can be adjusted to any...
Abrir o catálogo na página 5
— Specification – Operative limits Pressure limits Overpressure limits Without damage to the transmitter No damage will occur during transmitter operation, if they are used within the specifications and subject to the following limits: Model PxP100 Seal type Sensors The below table shows the maximum pressure limits of the connection when coupled with customer process interface. It also shows the compatibility of the sensor ranges. Pressure limit Universal G1" hygienic - AISI Universal G1" hygienic - HC Universal G1" hygienic Diaflex on AISI Seal model (Standard) Sensors L to R Diary 11851...
Abrir o catálogo na página 6
Temperature limits °C (°F) Ambient Seal model (Standard) Seal diaphragm size (thickness) / flange type PN 16 "Max. pressure Carbon steel flange @ 120 °C" "Max. pressure AISI 316 ss flange @ 20 °C" Ambient temperature limits Operating temperature range Process temperature limits Process temperature range Seal model (Standard) Seal diaphragm size (thickness) / flange type "Max. pressure AISI 316 L ss flange @ 20 °C" 1.6 Mpa, 16 bar, 230 psi Please refer to process temperature limits driven by S26 remote seals Process temperature limits Process temperature range EPDM gasket for universal...
Abrir o catálogo na página 7
— ...Specification – Operative limits Refer to the following FILL FLUID CHARACTERISTICS table detailing characteristics of fill fluids when used in transmitters. Operational limits may vary depending on the materials, gasket and configuration selected. Models Fill fluid (application) Process temperature and pressure limits Pmin mbar abs (mmHg) Inert oil Galden G5 (oxygen service) Silicone polymer Syltherm XLT (cryogenic service) Silicone oil for high temperature (for REMOTE SEAL) Silicone oil for high temperature (for DIRECT MOUNT SEAL) Vegetable oil Neobee M-20 (food - sanitary) FDA...
Abrir o catálogo na página 8
Model PGD100, PAD100 Seal system selection criteria The following table shows the types of seals available as direct mount and remote. According to the combination SEAL/TRANSMITTER SENSOR the table details the compatibility for one direct mount seal construction and the MAXIMUM CAPILLARY LENGTH when a seal is selected as remote. The mnemonics will be used as shortest cross references in the S26 data sheet. Seal model Seal type "Seal diaphragm size (thickness) [flange type]" Direct mount seal Remote seal Flanged flush diaphragm (ASME and EN standards) 1.5 in /DN 40 Wafer (ASME and EN...
Abrir o catálogo na página 9
— ...Specification – Operative limits Environmental limits Electromagnetic compatibility (EMC) The devices comply with the requirements and tests for EMC Directive 2014/30/EU to standards EN 61326-1 Table2 (industrial electromagnetic environment) concerning both emitted interference (CISPR11) and interference immunity. • Burst test: up to 2 kV at 5 kHz and 100 kHz • Surge test: up to 1 kV line-line and 2 kV line-ground Radiated emission: Group 1 - class B according to CISPR11 • FCC 47 CFR part 18.305 • ICES 005 - Issue 4 Conducted emission: group 1 - class A according to CISPR11 and to...
Abrir o catálogo na página 10
— Specification - Performance Reference conditions according to IEC 62828-1 • Ambient temperature constant in the range 15 – 25 °C (59 – 77 °F) • Relative humidity constant in the range 50 – 70 % • Ambient pressure constant in the range 860 – 1060 mbar • Measuring span based on zero position • Transmitter with AISI 316 L or Hastelloy C276 process isolating diaphragm • Filling fluid: Silicone oil • Supply voltage: 24 V DC ± 1 % • Load with HART: 250 Ω • Transmitter not grounded • Characteristic setting: linear, 4 – 20 mA. Unless otherwise specified, errors are quoted as % of calibrated span....
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas