ProcessMaster FEP610 Electromagnetic flowmeter The new flowmeter: The first choice for all industrial standard applications. Measurement made easy ABB common look and feel — Easy Set-up function — Simple and intuitive configuration — Through-the-glass configuration with capacitive switches — Backlit, rotatable LCD display — Configurable display pages SensorApplicationMemory — Secure storage of calibration and application specific data — Quick change-out of transmitter without reprogramming Verification und Online Diagnostic — Easy to check based on Fingerprint Technology - the reference signature of the device — Service Interval Monitoring. Message at end of service interval — Function and Simulation routines for all outputs Easy-to-understand diagnostic messages — Continuous monitoring of sensor and transmitter integrity and process conditions — Text in help menu in response to diagnostic results for fast and efficient error handling Change from one to two columns One single transmitter fits all design types — Integral mount design or remote mount design — With or without LCD display — Universal wide-range power supply Easily customizable output signals — Analog current output — Two fully configurable digital outputs Robust sensor design for rough environmental conditions — Real-world proven — Hermetically sealed flow sensor — Optimal Protection against Condensation, vibration and corrosion Ideally suited for industrial standard applications — Industry optimized liner materials, resistant to abrasion, long-lasting — Wide range of electrode materials, corrosion resistant for longest service life Simplified Spare Parts Handling — Common transmitter electronic results in significan
Abrir o catálogo na página 1
ProcessMaster FEP610 Electromagnetic flowmeter The Company ABB is an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a world leader in process automation technology our worldwide presence, comprehensive service and application oriented know-how make ABB a leading supplier of flow measurement products. Introduction Setting the standard for the process industry ProcessMaster is designed specifically to meet the increased requirements on advanced flowmeters. The...
Abrir o catálogo na página 2
Overview – models Flowmeter sensor Integral mount design 1 Remote mount design FEP611 Fig. 1: Designs 1 Flowmeter sensor, Design Level A (DN 3 … 2000) 2 Flowmeter sensor, Design Level B (DN 25 … 600) 3 Remote transmitter Flowmeter sensor Model Integral mount design, remote mount design Measuring accuracy for liquids Permissible measuring medium temperature Tmedium Minimum conductivity > 20 μS/cm (20 μS/cm for demineralized water) Nominal pressure rating Nominal diameter Process connection Process connection material Steel, cast iron, stainless steel Liner material Hard rubber (DN 15 ......
Abrir o catálogo na página 3
ProcessMaster FEP610 Electromagnetic flowmeter Transmitter Model Integral mount design (see Fig. 1), remote mount design. Cable length Maximum 50 m (164 ft), remote mount design only Power supply Digital output 1: passive, configurable as pulse, frequency or switch output Digital output 2: passive, configurable as pulse or switch output Local display Configurable graphical display (option) Approvals — Further approvals Change from one to two columns Measuring principle Measurements performed by the electromagnetic flowmeter are based on Faraday’s law of induction. A voltage is generated in...
Abrir o catálogo na página 4
Flowmeter sensor Repeatability, response time Measuring accuracy Reference conditions Repeatability Response time 1) As step function 0 ... 99 % 5 200 ms at 25 Hz excitation frequency According to EN 29104 Measuring medium ≤ 0.11 % of measured value, tmeas = 100 s, v = 0.5 ... 10 m/s temperature Ambient temperature Power supply Nominal voltage acc. to name plate 1) Of current output with damping of 0.02 seconds. U = ±1 %, Frequency f = ±1 % Installation condition — Upstream >10 x DN, straight section — Downstream >5 x DN, straight section Warm-up phase Measuring error and repeatability...
Abrir o catálogo na página 5
ProcessMaster FEP610 Electromagnetic flowmeter Permitted pipe vibration In accordance with EN 60068-2-6. Applicable to sensors in remote mount design and sensors in integral mount design. — Maximum deflection: 0.15 mm (0.006 inch) in the 10 ... 58 Hz range — Maximum acceleration: 2 g, in the 58 ... 150 Hz range IP rating — IP 65 / IP 67 in accordance with EN 60529 — IP 68 in accordance with EN 60529 (for remote mount design only) Signal cables For remote mount design only. The maximum signal cable length between flowmeter sensor and transmitter is 50 m (164 ft). A 5 m (16.4 ft) cable is...
Abrir o catálogo na página 6
Ambient temperature as a function of measuring medium temperature Integral mount design Liner material Flange material Ambient temperature range (Tamb.) Minimum Hard rubber Hard rubber Stainless steel Measuring medium temperature range (T medium) Soft rubber Soft rubber Stainless steel Stainless steel Stainless steel Stainless steel 1) For China production site only. 2) The maximum measuring medium temperature is reduced to 80 °C (176 °F) for design level "B" sensors with a hard rubber liner. Remote mount design Liner material Flange material Ambient temperature range (Tamb.) Minimum Hard...
Abrir o catálogo na página 7
ProcessMaster FEP610 Electromagnetic flowmeter Measuring range table The flow range end value can be set between 0.02 x Qmax DN and 2 x QmaxDN. Nominal diameter Minimum flow range end value Maximum flow range end value (845 US gal/min) (1162 US gal/min) (1374 US gal/min) (4755 US gal/min) (5548 US gal/min) (6340 US gal/min) Change from one to two columns
Abrir o catálogo na página 8
Process connections For an overview of the available process connection variants, see the chapter entitled "Overview – models" on page 3. Sensor housing Part / DN Design level "A" sensor Housing Installation length The flange devices comply with the installation lengths specified in ISO 13359, or according to DVGW (process sheet W420, design WP, ISO 4064 short). For further details, refer to chapter "Dimensions" on page 17. Cast aluminum (painted) Paint coat: ≥ 80 μm thick, RAL 9002 Welded steel design (painted) Paint coat: ≥ 80 μm thick, RAL 9002 Meter tube Plastic, gray white, RAL 9002...
Abrir o catálogo na página 9Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas