Grupo: ABB
Excertos do catálogo

• ASTM D7041-04 • On-line Measurement of Total Sulfur • Simple Analysis Method • Minimal Hardware • Proven Gas Chromatograph Flame Photometric Detection • Low Range Sensitivity Application The demand for on-line measurement of fuel sulfurs in refi neries is growing as environmental regulators enact more stringent limits on sulfur levels in motor fuels. Availability of sweet crudes has decreased while legislation continues to lower the permissible levels of sulfur in motor fuels to decrease pollution. As these sulfur limits continue dropping, very few on-line process analyzers can measure the total sulfur levels accurately and reliably. But, the PGC2007 E2 Process Gas Chromatograph with a Flame Photometric Detector (FPD) by ABB Analytical provides a fi eld–proven on-line method, measuring trace levels of Total Sulfur in fuels. Method The Environmental Regulations, which continue to evolve, set the anticipated limit for total sulfur in gasoline and diesel fuel. In response, various technologies for gasoline and diesel fuel analysis have appeared on the market: x-ray dispersion, electrochemical methods, lead acetate paper tapes, UV fl uorescence and gas chromatography. Recent ASTM test results show most of these methods to provide inadequate repeatability and reproducibility for both gasoline and diesel samples, especially at the lower ranges soon to be required. The method employed in the PGC2007 E2 from ABB performs with excellent repeatability and reproducibility. Total Sulfur in Fuels PGC2007 E2 Series Process Gas Chromatographs
Abrir o catálogo na página 1
The PGC2007 E2 from ABB utilizes gas chromatography and an oxidation furnace for total sulfur measurement. Unlike some of the other more hardware–intensive methods mentioned, the PGC2007 E2 utilizes our fi eld-proven Flame Photometric (FPD), known for its reliability and simplicity. The features and performance of the complete analyzer system make ABB Analytical the leader in process chromatography for Total Sulfur. Simplicity — Injection, Oxidation, Separation, Measurement The platform is familiar to your technicians; in addition, its simple furnace converter, and proven FPD technology...
Abrir o catálogo na página 2
Superior Chromatography, Linearity & Reproducibility Total Sulfur in Gasoline - 14.8 PPM Total Sulfur in Diesel - 20 PPM Overlay of Total Sulfur Chromatograms Diesel Reproducibility Gasoline Reproducibility
Abrir o catálogo na página 3
BUASC1A-20-0609 Specifi cations subject to change without notice. A World Class Analyzer Meets World Standards The PGC2007 E2 is designed turnkey to meet current and emerging international standards such as ATEX, CSA, and NEC/ NRTL. In most cases, the standard confi guration meets all required international standards, minimizing analyzer variants and assuring consistent performance and safety. Superior VN2300 Connectivity Integration of the PGC2007 E2 into the process control loop is readily achieved with the ABB VN2300 (formerly VistaNET) Integrated Process Analyzer Network Architecture....
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas