Grupo: ABB
Excertos do catálogo

OriMaster FPD500 Compact orifice flowmeter Measurement made easy Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly — combines primary element with DP transmitter in a single flowmeter assembly Reduced installation costs — only one piece to install — eliminates need to supply and connect separate manifold, transmitter and impulse piping Mass flow version with optional, integral temperature element — integral multivariable transmitter and RTD for direct reading of mass (liquids and steam) and corrected volume (gas) flowrates in a single unit Easy to specify and maintain — single ordering code covers complete flowmeter — only two orifice ratios for simple specification process — optional replaceable orifice plates offer easy, economic maintenance and flexibility for changing process conditions Plugged impulse line detection — detects partial or complete blockage of DP connections — provides warnings visually and via outputs New 'through-the-glass' (TTG) keypad technology — enables quick and easy local configuration without the need to open the cover – even in hazardous areas Integral impulse connections — no impulse piping installation required — provides repeatable DP connection across installation locations Factory acceptance report — supplied with report detailing results of critical inspection chec
Abrir o catálogo na página 1
OriMaster FPD500 Compact orifice flowmeter OriMaster – the one-piece DP flowmeter Benefits OriMaster is a stand-alone orifice-based flowmeter with a difference – its advanced design greatly simplifies installation and commissioning. OriMaster incorporates the following features: — A wafer-bodied orifice carrier assembly with integral square-edged, concentric plate and corner tapping points — Integral 3-valve manifold (optional 5-valve manifold available) — Integral direct connections between the carrier tappings and manifold — DP transmitter, factory-mounted onto the manifold and...
Abrir o catálogo na página 2
Basic principle of operation DP devices work on a principle based upon the Law of Conservation of Energy, where a restriction in the fluid path causes an acceleration in the fluid velocity with a corresponding increase in kinetic energy. The gain in kinetic energy is at the expense of pressure energy, resulting in a drop in fluid pressure across the narrowest part of the restriction. The drop in pressure and the flow rate are linked by the following (simplified) relationship: Q = k DP where Q = fluid flow rate k = a constant for that DP device The Vena Contracta increases the velocity...
Abrir o catálogo na página 3
OriMaster FPD500 Compact orifice flowmeter Versions OriMaster is available in two versions: OriMaster V – a compact flowmeter for general purpose measurement in volumetric units (actual volume). OriMaster V uses the ABB 364 or 266 DP transmitter to provide a flow rate and total display and a 4 to 20 mA output proportional to the actual volume flowrate. The transmitter case and meter body are all in stainless steel as standard when the 364 transmitter is fitted. 316 stainless steel transmitter cases are also available. There are 5 DP sensor ranges available. For optimum accuracy select the...
Abrir o catálogo na página 4
OriMaster M – a compact flowmeter, providing measurement directly in mass units for liquids and steam. Gas flow is measured directly in reduced volume units. OriMaster M uses the ABB 267 multivariable transmitter to measure DP, temperature and pressure, providing a flowrate display and a 4 to 20 mA output proportional to the mass or corrected volume flowrate. The body is stainless steel and the case is alloy (stainless steel optional). An optional internal temperature element is available. There are 3 DP sensor ranges available. For optimum accuracy select the sensor so that the full scale...
Abrir o catálogo na página 5
OriMaster FPD500 Compact orifice flowmeter Specification – general Fluids Liquids, gases and saturated steam Line sizes 25, 40, 50, 80, 100, 150, 200, 250 and 300 mm (1, 11/2, 2, 3, 4, 6, 8, 10 and 12 in.) Output signal — Two-wire, 4 to 20 mA, selected for square-root output — Low flow cut-off facility — HART® communication provides digital process variable (%, mA or engineering units) superimposed on 4 to 20 mA signal, with protocol based on Bell202 FSK standard — Optional Profibus PA, Foundation Fieldbus or Modbus communications (OriMaster M only) Output current limits (to NAMUR standard)...
Abrir o catálogo na página 6
Wetted materials Orifice assembly, stem and manifold 316L stainless steel Transmitter sensor housing OriMaster V: — Aluminum alloy (266DSH transmitter) (316L stainless steel optional) — 304L stainless steel (364DS transmitter) (316L stainless steel optional) OriMaster M: — Aluminum alloy (316L stainless steel optional) Process isolating diaphragms Hastelloy C276 (NACE) Seals Transmitter to manifold: — PTFE Manifold: — Graphite, PTFE Process connections Wafer body to fit between the following flange drillings — ASME B16.5 (ANSI) Class 150, 300 or 600 — DIN PN16, PN25, PN40 or PN100 Pipeline...
Abrir o catálogo na página 7
OriMaster FPD500 Compact orifice flowmeter Orifice plate bore at 20 °C (68 °F): For Beta = 0.4 — 25 mm (1 in.) 10.66 mm (0.42 in.) 16.36 mm (0.644 in.) — 40 mm (11/2 in.) — 50 mm (2 in.) 20.99 mm (0.826 in.) — 80 mm (3 in.) 31.17 mm (1.227 in.) — 100 mm (4 in.) 40.90 mm (1.610 in.) — 150 mm (6 in.) 61.63 mm (2.426 in.) — 200 mm (8 in.) 81.10 mm (3.193 in.) — 250 mm (10 in.) 101.8 mm (4.008 in.) — 300 mm (12 in.) 121.29 mm (4.775 in.) Weight in kg (lb) (approximately) Size 25 mm (1 in.) 40 mm (11/2 in.) Upstream straight pipe requirements to ISO 5167:2003 Fitting 2 off 90 º bends in same...
Abrir o catálogo na página 8
Performance System accuracy at reference conditions (for Re >105) Uncalibrated % Vol. flow rate % Mass flow rate Size in mm (in.) Model OriMaster V OriMaster M Calibrated ABB standard water calibration (3 points over a 5:1 flow range) System accuracy: — ± 1 % of flowrate Repeatability OriMaster V: — 0.1 % OriMaster M: — 0.1 % Turndown OriMaster V: — up to 8:1 OriMaster M: — up to 8:1 OriMaster FPD500 | Compact orifice flowmeter | DS/FPD500–EN
Abrir o catálogo na página 9Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas