Grupo: ABB
Excertos do catálogo

ABB MEASUREMENT & ANALY TICS | DATA SHEET LMT200 external mount magnetostrictive level transmitter High accuracy non–intrusive liquid level and interface level detectio
Abrir o catálogo na página 1
— Measurement made easy K–TEK Level products — Features • Calibrated from the factory • High accuracy: .01 % of full scale or ±1.27 mm • No re–calibration needed: set it and forget it • Easy setup with waveform display • Not affected by agitation, foam or emulsion layers • No oscilloscope required • Designed to mount externally to K–TEK KM26 or other magnetic level gauge • Superior sensor (patent #5,473,245) • Local indication with HMI display • Dual compartment housing with separate field terminal compartment • Loop powered to 15.24 m (50 ft) probe length • Total and/or interface level...
Abrir o catálogo na página 2
— Principle of operation: The LMT200 is based upon the magnetostrictive principle. 1 1 The device electronics generates a low energy current pulse at fixed intervals. 2 The electrical pulses create a magnetic field which 2 travels down a specialized wire inside the sensor tube. 3 3 The interaction of the magnetic field around the wire and the magnetic float causes a torsional stress wave to be induced in the wire. This torsion propagates along the wire at a known velocity, from the position of the magnetic float and toward both ends of the wire. 4 4 A patented sensing element placed in the...
Abrir o catálogo na página 3
LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Electronic transmitter Repeatability ±0.005 % Of full scale or 0.315 mm (0.012 in), whichever is greater Non-linearity ±0.01 % Of full scale or 0.86 mm (0.034 in), whichever is greater Measuring accuracy ±0.01 % Of full scale or 1.27 mm (0.050 in), whichever is greater1 Supply voltage 12 to 43 V DC for 4 to 20mA HART loop powered, 9.0 to 32 V DC for Foundation™ Fieldbus Output/Communications 4 to 20 mA HART7® or FOUNDATION Fieldbus ITK6.3.0 User interface Interactive display, DTM,...
Abrir o catálogo na página 4
— Float design for ABB K–TEK products – KM26S Every KM26 MLG float is precisely engineered to customer applica ion, ensuring optimal accuracy and performance. t Precisely spaced magnets create a 360° magnetic field coverage, safeguarding level transmitter and gauge performance, even the most challenging applications. Several materials of construction available including titanium, Monel®, Hastelloy® C, stainless steel, and plastics. Tefzel®, Halar®, TEFLON® S protective coatings are also available. Process pressures to 344 bar (5000 PSI) to full vacuum. A minimum of 75 grams of buoyancy are...
Abrir o catálogo na página 5
— Electrical connections Devices with HART communication Current output/HART output Terminal Power supply, current output/HART output PWR/COMM – EXT.METER Internal earthing terminal Power supply, current output/ 7 HART output 9 2 8 3 3 Load resistance 7 4 4 Power supply/supply isolator 5 5 PLC/DCS 6 HART handheld terminal 6 7 External indicator 7 8 External earthing terminal 8 9 Terminal for external indicator 9 0 Laptop 10 For connecting the signal voltage/supply voltage, twisted cables with a conductor cross–section of 0.8 to 0.35 mm2 (18 to 22 AWG )and a maximum length of 1500 m (4921...
Abrir o catálogo na página 6
— Power supply Devices with HART communication Terminals PWR/COMM +/PWR/COMM – Supply voltage Residual ripple Power consumption Current Output/HART output Only for devices with HART communication Terminals: PWR/COMM +/PWR/COMM – In HART communication, the smallest load is RB = 250 Ω. The load is RB is calculated as a function of the available supply voltage US and the selected, signal current IB as follows: US – min operating voltage (12.0) V DC RB Load resistance US Supply voltage IB Singal current Internal ground termination point Fieldbus lines Devices with Foundation Fieldbus...
Abrir o catálogo na página 7
— ...Probe selection guide Probe selection chart - standard 85 (185) Directions: 1. determine the maximum ambient tempearture and the maximum process temperature of the installation. 2. Plot the intersection between the two temperatures on the chart. 3. Choose the appropiate probe by matching the zone number with the probe type. *Ambient temperature is the air temperature in the work area surrounding the device. It takes into account the influence of heat created by equipment surrounding the area personnel will be working. It is not the skin temperature of the chamber or insulation blanket....
Abrir o catálogo na página 8
LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Approvals General purpose INMETRO, ATEX/IECEx flameproof, intrinsically safe, no-sparking (protection type marked by customer) NEPSI (China), intrinsically safe NEPSI (China), flameproof housing NEPSI (China), non-sparking NEPSI (China), ATEX/IECEx flameproof, intrinsically safe, non-sparking (protection type marked by customer) ATEX/IECEx intrinsic safety ATEX/IECEx flameproof housing ATEX/IECEx flameproof non-sparking (Ex nA) EAC, intrinsically safe EAC, flameproof housing EAC, non-sparking Multi-approval -...
Abrir o catálogo na página 9
LMT200 EXTERNAL MOUNT MAGNETOSTRICTIVE LEVEL TRANSMITTER | DS/LMT200-EN REV.D Mounting orientation Bottom left connected electronic housing Bottom right connected electronic housing Top left connected electronic housing Top right connected electronic housing Housing Aluminum with 2 x M20 x 1.5 Aluminum with 2 x NPT V2 in 316L stainless steel with 2 x M20 x 1.5 316L stainless steel with 2 x NPT V in Remote/aluminum/2 x M20 x 1.5* Remote/aluminum/2 x NPT V in* Remote/stainless steel/2 x M20 x 1.5* Remote/stainless steel/2 x NPT V in* Special Through the glass (TTG) push buttons, display and...
Abrir o catálogo na página 10
Sensor probe options 90 degree bend housing extension (maximum probe length 7.62 m/25 ft) Add nitrogen purged vapor seal to standard probe Sensor special Device identification plate Add stainless steel hang tag, custom markings 4 lines, 22 characters per line Other tagging special Signal cable length (for remote transmitter only) 5 m (approx. 16 ft)* Surge protector Surge/transient protector Special other Special paint or treatment on housing Nuclear use, device to be used in a nuclear facility (application must be reviewed by ABB) Mounted accessories Mounted to chamber with vibration...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos ABB Measurement & Analytics
-
FSM4000 Electromagnetic Flowmeter
72 Páginas
-
Sensyflow FMT700-P Compact
4 Páginas
-
CoriolisMaster FCB100, FCH100
60 Páginas
-
ProKiln GAC400
24 Páginas
-
Open up a new world of water analysis
12 Páginas
-
AV1 and AV2
24 Páginas
-
LP Linear pneumatic piston actuator
28 Páginas
-
OriMaster FPD500
24 Páginas
-
AquaProbe FEA200
16 Páginas
-
FTPA2000-HP260
4 Páginas
-
TSM800 Multipoint temperature sensor
8 Páginas
-
266HSH and 266NSH
40 Páginas
-
261GC, 261GG, 261GN and 261AC
44 Páginas
-
LM200 Laser level transmitter
24 Páginas
-
LLT100 Laser level transmitter
26 Páginas
-
FPD350 Torbar Averaging pitot tubes
56 Páginas
-
CoriolisMaster FCB400, FCH400
104 Páginas
-
PME120-AI / PME120-AN (Contrac)
28 Páginas
-
TX - Thermal dispersion switch
5 Páginas
-
Millmate roll force systems
20 Páginas
-
FTSW100 Process software
4 Páginas
-
Totalflow host software
8 Páginas
-
SCK
20 Páginas
-
Plunger Analysis Software (PAS)
4 Páginas
-
SCADAvantage™ EFM Tool
4 Páginas
-
INDI-BOY DSP
8 Páginas
-
CRANE-BOY / CRANE-BOYP
8 Páginas
-
9QGPS5100L Tension load cell
12 Páginas
-
9QGPS4500
8 Páginas
-
9QGPS3100P
12 Páginas
-
9QGPS2960
12 Páginas
-
9QGPS2625
8 Páginas
-
Ultrasonic level LST400
12 Páginas
-
MB3600-HP10
5 Páginas
-
MB3600-CH10
8 Páginas
-
ACF5000
16 Páginas
-
Diode laser analyser LS4000
4 Páginas
-
Magnos28
10 Páginas
-
Dynamic QR Code
4 Páginas
-
EL3060
8 Páginas
-
Pressductor Radial load cells
20 Páginas
-
HP30
4 Páginas
-
Aztec ATS430
12 Páginas
-
LMS200
12 Páginas
-
PGC5000
8 Páginas
-
LGR-ICOS 927S
4 Páginas
-
Recording and Control
20 Páginas
-
2600T Pressure Transmitters
12 Páginas
-
TZIDC and TZIDC-200
8 Páginas
-
ProcessMaster FEP610
8 Páginas
-
ALSCAN Brochure
6 Páginas
-
MR Series
2 Páginas
-
Emission Monitoring
8 Páginas
-
Variable Area Flowmeters - VA Master
12 Páginas
-
Compact Orifice Flow Meter OriMaster
12 Páginas
-
Thermal Mass Flowmeter Sensyflow
8 Páginas
-
Turbidity Systems 4670 Series
16 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
Residual Chlorine Monitor AW400
8 Páginas
-
Aztec 600 Iron Analyzer
12 Páginas
-
First for Liquid Analysis
16 Páginas
-
Aluminium Analyzer Aztec 600 Aluminium
12 Páginas
-
ABB product catalog
32 Páginas
-
process photometer
6 Páginas
-
Mass Flowmeter CoriolisMaster
8 Páginas
-
Sodium Monitor Model 8036
8 Páginas
-
PH/Redox (ORP) Sensor for Critical Processes
16 Páginas