LLT100 Laser level transmitter
1 / 26Páginas

Excertos do catálogo

LLT100 Laser level transmitter - 1

ABB MEASUREMENT & ANALY TICS | DATA SHEET LLT100 Laser level transmitter Measurement made easy

Abrir o catálogo na página 1
LLT100 Laser level transmitter - 3

— Customer benefits — Main features The LLT100 is specifically made for industrial applications and harsh environments. It provides continuous, non-contact level measurement capabilities for process automation and inventory management in industries such as mining, aggregates, oil and gas, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, and water and waste water. ABB brings level transmitters to the next level of non-contact measurements by packaging laser ranging technology with the features required by industrial applications. Using a pulsed laser to perform...

Abrir o catálogo na página 3
LLT100 Laser level transmitter - 4

— Product configurations Base model Ideal for measuring levels of solids at up to 100 m (328 ft), and liquids at up to 30 m (98 ft) when the process is at normal pressures. This affordable and powerful level transmitter can be used in a wide variety of applications, including hazardous areas. Range Process fitting Operating temperature Process pressure Accuracy 0.5 to 100 m (2 ft to 330 ft) ASME class 150, NPS 2 in DN 50 PN 16 flat face –40 to 60 °C (–40 to 140 °F) –1 to 2 bar (29 psi) 11 mm (0.4 in) Hygienic model Ideal for food and beverage or pharmaceutical applications. Model fitted...

Abrir o catálogo na página 4
LLT100 Laser level transmitter - 5

— Product configurations High pressure model Ideal for high-pressure applications. Same performance as the base model, but fitted with a choice of pressure-rated flanges. As with all models, it is certified for use in hazardous area zone 1, and its laser beam can be sent safely into zone 0. Range Process fitting Process temperature Process pressure Accuracy 0.5 to 100 m (2 to 330 ft) ASME class 150/300, NPS 2 in DN 50 PN 16/40 raised face –40 to 60 °C (–40 to 140 °F) –1 to 49.6 bar (719 psi) 11 mm (0.4 in) Accessories Configure the transmitter to a wide variety of applications. • Dust tube...

Abrir o catálogo na página 5
LLT100 Laser level transmitter - 6

Rotating display with touch through-the-glass interface Industrial housing, IP67 and explosionproof class 1/division 1 (also zone 1) Pressure-rated flanges available Powered from a 4 to 20 mA loop, HART communication Eye safe, class 1 laser beam — Advantages and new features The laser transmitter measures any solid or liquid, at short or long range. A single configuration can meet a wide variety of requirements. The LLT100 can be used in challenging hazardous areas, in the presence of potentially explosive dust or gases. It can be used in class 1/division 1 (zone 1) environments. For...

Abrir o catálogo na página 6
LLT100 Laser level transmitter - 7

— Solid applications A typical LLT100 application is to measure the level of solids in silos and tanks. These vessels can be found in various industries such as mining, aggregates, chemicals, food and beverages, power, pulp and paper, pharmaceuticals, etc. The high sensitivity of the LLT100 allows level measurements in tall vessels. The transmitter's narrow laser beam can be precisely aimed to circumvent obstacles. Its installation is very flexible, as the transmitter can be placed close to the wall or angled inside the vessel. Finally, material build-up on vessel walls has no effect on the...

Abrir o catálogo na página 7
LLT100 Laser level transmitter - 8

— Mixer/obstruction Another challenge in the field of level measurement is obtaining reliable measurements in the presence of obstructions or mixing blades. The very narrow beam (<0.3 degrees) of the LLT100 allows installation of the instrument at almost any place on top of the vessel and its positioning between the vessel wall and the edge of the mixer, thus providing reliable measurements. When it is not possible to avoid the mixer blades, the LLT100 has advanced processing functions that can still perform the measurement reliably by efficiently tracking the real level when the mixer...

Abrir o catálogo na página 8
LLT100 Laser level transmitter - 9

— Specification Measurement Range 0.5 to 30 m (2 to 100 ft) for liquids 0.5 to 100 m (2 to 330 ft) for solids 0.5 to 200 m (2 to 660 ft) for positioning applications1 Resolution 5 mm (0.2 in) Typical accuracy 11 mm (0.4 in) Measuring beam Laser wavelength: 905 nm, eye safe, Class 1 Laser beam divergence < 0.3° Housing material Powder coated aluminum (standard), 316L stainless steel (SST)(option) Dimensions (W × H × D) Universal – flat flange: 247 × 215 × 165 mm (9.7 × 8.5 × 6.5 in) Class 150 – raised flange: 240 × 242 × 154 mm (9.5 × 9.5 × 6.1 in) Class 300 – raised flange: 247 × 242 × 165...

Abrir o catálogo na página 9
LLT100 Laser level transmitter - 10

— Specification Operation Display Integrated 128 × 64 pixels LCD display with through-theglass (TTG) interface Software features Volume computation, damping, filtering, thresholds/ alarms, user-defined display (with HMI) Measuring laser 905 nm near infrared pulsed semiconductor laser 7.1 μW average power output 45 W peak power output Measuring laser safety Always on IEC60825–1 Ed. 2, 2007 A Class 1 laser is safe for all conditions of use. Optical Total optical aperture 50 mm (2 in) Standard window material (flanges A and B) Tempered borosilicate glass Pressure rated window material (flanges...

Abrir o catálogo na página 10
LLT100 Laser level transmitter - 11

ATEX Directive 2014/34/EU Electromagnetic compatibility Directive (EMC) 2014/30/EU Low Voltage Directive (LVD) 2014/35/EU Restriction of Hazardous Substances Directive (RoHS) 2011/65/EU ATEX, IECEx, KCs (flameproof/explosion proof/dust-ignition proof version) ATEX: FM16ATEX0032X, IECEx: FMG 16.0023X, KCs registration no: 17–AV4BO–0305X For flanges A and B: II 2 (1) G Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C II 2 (1) D Ex tb [op is Da] IIIC T85°C…T100°C Db –50 °C ≤ Ta ≤ +75 °C…+85 °C – IP66/ IP67 Ex db [op is T6 Ga] IIC T6…T5 Gb –50 °C ≤ Ta ≤ +75 °C…+85 °C Ex tb [op is...

Abrir o catálogo na página 11
LLT100 Laser level transmitter - 12

Russia custom union Ex–мapкиpовкa ypoвнeмepoв c Флaнцaми A и B ypoвнeмepoв c Флaнцaми C, D, F и G Functional safety Random capability : Type B element, SIL 2 @ HFT = 0 ; route 1H Systematic capability : SC2 (SIL 2 capable) 1Ex db [ob isT6 Ga] IIC T6… T5 Gb X, Ex tb [op is Da] IIIC T85°C…T100°C Db X Ga/Gb Ex db [opis T6 Ga] IIC T6…T5 X, Ex tb [op is Da] IIIC T85°C

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos ABB Measurement & Analytics

  1. ProKiln GAC400

    24 Páginas

  2. AV1 and AV2

    24 Páginas

  3. OriMaster FPD500

    24 Páginas

  4. AquaProbe FEA200

    16 Páginas

  5. FTPA2000-HP260

    4 Páginas

  6. 266HSH and 266NSH

    40 Páginas

  7. SCK

    20 Páginas

  8. INDI-BOY DSP

    8 Páginas

  9. 9QGPS4500

    8 Páginas

  10. 9QGPS3100P

    12 Páginas

  11. 9QGPS2960

    12 Páginas

  12. 9QGPS2625

    8 Páginas

  13. MB3600-HP10

    5 Páginas

  14. MB3600-CH10

    8 Páginas

  15. ACF5000

    16 Páginas

  16. Magnos28

    10 Páginas

  17. Dynamic QR Code

    4 Páginas

  18. EL3060

    8 Páginas

  19. HP30

    4 Páginas

  20. Aztec ATS430

    12 Páginas

  21. LMS200

    12 Páginas

  22. PGC5000

    8 Páginas

  23. LGR-ICOS 927S

    4 Páginas

  24. ALSCAN Brochure

    6 Páginas

  25. MR Series

    2 Páginas