video corpo

HDT/Vicat Allround_cool
2Pages

{{requestButtons}}

Catalog excerpts

HDT/Vicat Allround_cool - 1

Product Information HDT/Vicat Allround with integrated cooling unit HDT/Vicat 6300 Allround, motorized test weight application Range of applications Determination of Heat Deflection Temperature (HDT) on thermoplastics, hard rubber, as well as fiber reinforced and filled hardenable plastics, according to ISO 75 Parts 1 to 3 and ASTM D 648 Method A and B Determination of Vicat Softening Temperature (VST) on thermoplastics, according to ISO 306 and ASTM D 1525 Determination of creep test characteristics under deflection loading PI 603 2.0312 Description The HDT/Vicat Allround instruments have been designed for comfortable testing in research and development, incoming goods control, product monitoring as well as for education and training purposes. Various instruments with up to 6 testing stations are available. testXpert® II enables convenient parametrization of the test sequence and display of test values. Automatic test sequence As soon as the immersion liquid has reached the starting temperature, the specimens are placed in the testing stations and manually lowered into the bath. The next step is to place the test weight, called for by the standard, manually or optionally motorized, and then start the test sequence from the PC Software. After pretempering while under load, the travel signals are set to zero by the program, and the heating of the immersion liquid is started with the preset heating rate. As soon as the required flexure, edge fiber extension or penetration is achieved at all stations, the heating is switched off and the test is ended. The cooling of the immersion liquid is started automatically by the program via magnetic valve and then the specimens can be taken out of the bath. Functions, elements and interfaces • Builtin SPScontrol for temperature regulation and test data acquisition • Cooling controlled by magnetic valve • Motorized immersion of the testing stations • Manual or optional motorized placing of the test weights • Safety thermostat • Electronic bath level monitoring • Test control and data acquisition via PC with testXpert® II (RS232Interface required in PC) • Integrated compensation of the thermal expansion Cooling of the immersion liquid The instruments are equipped with an integrated cooling unit for short cooling times. Specimen data VST specimen dimensions, max.: 10 x 6.5 x 10 mm HDT specimen dimensions, max.: 13 x 15 x 130 mm HDT support distances: 64 and 100 mm (optional 101.6 mm)

Open the catalog to page 1
HDT/Vicat Allround_cool - 2

Zw/ck # Roell Materials Testing Product Information HDT/Vicat Allround with integrated cooling unit Number of testing stations Test weight application Oil filling quantity [I], approx. Height x Width x Depth [mm] Weight (w/o access.) [kg], approx. (1 Expandable by retrofitting up to 6 testing stations (2 Water supply required Technical data for all instruments Ambient temperature curve ± 0.2 °C Resolution of temperature measurement 0.1 °C Temperature sensors: 1 x measurem. of the bath temperature, in addition, 1 sensor near the specimen for each testing station. Heating time: 50 K/h, 120...

Open the catalog to page 2

All ZwickRoell GmbH & Co. KG catalogs and technical brochures

  1. Image Brochure

    20 Pages

Archived catalogs

  1. Zwick/ZHU250

    3 Pages

  2. HC range

    2 Pages

  3. roboTest A

    2 Pages

  4. ProLine

    2 Pages

  5. testXpert II

    20 Pages