ODAC® 34XY
4Pages

{{requestButtons}}

Catalog excerpts

ODAC® 34XY - 1

Extremely Fast and Accurate Laser Diameter Measuring Head. Dual-Axis (XY), with 34 mm (1.34 in.) Measuring Field. ODAC® 34XY Display unit (option): VISU-Touch or LOC 01 Modern two axis measuring head from the ODAC® laser measuring unit series. Highest accuracy, robustness, reliability and functionality distinguish all the laser measuring heads from ZUMBACH. Thanks to the compact design, the ODAC® 34XY measuring heads can be used in virtually every manufacturing process in the wire and cable industry, the plastics and rubber industry as well as the steel and metal industry. Known for precision, quality and ease of use the laser measuring heads from ZUMBACH are among the best of their class. The technological basis considered for these measuring heads is always of the latest cutting edge technology, with laser diodes as light sources combined with intelligent and powerful measured-value processors which facilitate a simple and flexible integration. Our long-standing experience as a pioneer of in-line measuring technology, combined with high production figures result in a product with an excellent priceperformance ratio. Amongst the outstanding features are features such as single scan calibration (CSS), single scan monitoring and high data rate output of up to 300* data packages per second. The measuring heads can be used with all line speeds. Vibrations during production have no noticeable influence on measurements. Adaptive signal processing in the measuring units increase accuracy All the measuring heads of the ODAC® series have adaptive signal processing (patent DE3111356), which makes subsequent regular re-calibrations superfluous. Only in instances of component exchange or compliance to calibration regulations ISO 9001 etc. would recalibration be required. Main Advantages • Very high scan rate (measuring frequency) Standard: 2 x 1200/s, Version F: 2 x 2500/s • High precision measurement • High insensitivity to dirt and dust • Easily removable splash guards (snap in/out) Flexible communication integration • RS (-232 /-422 /-485) • PN (Profinet IO V2.3) • DP (Profibus DP) • EI (EtherNet/IP) for connection • EN (Ethernet TCP/IP) • J (digital, to USYS processors) All the relevant parameters for accuracy are continuously monitored by the measuring system and automatically compensated. This is valid in particular also for possible long-term changes of the behaviour of the scanner motor or the measuring electronics. * Depending on the measuring head model, the number of transmitted measured values as well as the baud rate of the interface. Di

Open the catalog to page 1
ODAC® 34XY - 2

System Overviews ODAC® 34XY-EN-RS (serial interface) Option: Local display LOC 01 Host RS-232 /-422 /-485 More applications with RS-485 interface and ANSI protocol Option: Analogue interface Digital input for length detector Service Ethernet TCP/IP The built-in processor allows the acquisition and monitoring of the measured values, as well as statistic functions, parameter selection and many other functions. The RS version communicates via the integrated RS interface with a higher level system, like USYS from Zumbach, Host Option: Display unit VISU-Touch computer (or PLC). The Zumbach...

Open the catalog to page 2
ODAC® 34XY - 3

Accessories Description Order Number Pivoting support, DVW 1-34XY-J/-JN-FDVW.101.03400 Mechanical device which pivots the measuring head continuously around the normal measuring axis within +/- 2.5°, 5°, 7.5° or 10° (selectable). With this method, the height and width of the profile can be measured accurately, regardless its angular position (twist). With steel rollers (V shape) and counter rollers. Infinitely adjustable onto the product diameter from 0…34 mm (0…1.34 in.). It is very suitable to damp product vibrations. For a continuos adjustment of the inclination of both measuring axes...

Open the catalog to page 3
ODAC® 34XY - 4

Technical Data Model ODAC 34XYMeasurement Measuring field M 1) Min. object ø Scanning frequency Scanning speed Width of laser beam 3) 5) Repeatability (3 σ) Measurement error Resolution 2) Light source 4) Interfaces / Connections Interface Service Interface Host Data rate max. standard Data rate max. F version Interface LOC Interface I/F Indicator of contamin. windows LED Service interface LED Host interface Energy supply Mains voltage Operating range Mains frequency Operating range Power 34 x 34 mm (1.34 x 1.34 in.) 0.15 mm (.006 in.) 2 x 1200 scans/s (standard); F version: 2 x 2500...

Open the catalog to page 4

All ZUMBACH Electronic AG catalogs and technical brochures

  1. KW 13/33TRIO

    4 Pages

  2. UMAC® CI

    2 Pages

  3. ODAC® 64XY

    4 Pages

  4. ODAC® 14XY

    4 Pages

  5. CELLMASTER®

    4 Pages

  6. ODAC-USYS

    6 Pages

  7. CAPAC® HS

    4 Pages

  8. ODEX® 10

    4 Pages

  9. RAYEX® D XT

    6 Pages

  10. RAYEX® S

    4 Pages

  11. USYS Touch

    4 Pages

  12. USYS IPCe

    6 Pages

  13. USYS 200

    4 Pages

  14. ODAC® 110XY

    4 Pages

  15. ODAC® 550

    4 Pages

  16. ODAC® 310

    4 Pages

  17. ODAC® 230

    4 Pages

  18. ODAC® 160

    4 Pages

  19. ODAC® 100

    4 Pages

  20. ODAC® 60J

    4 Pages

  21. VISU-Touch

    1 Pages

  22. USYS 20

    4 Pages

  23. BENDCHECK

    4 Pages

  24. DVO 2

    2 Pages

  25. DVW 1

    2 Pages

  26. AUTAC 300

    2 Pages

  27. ECOGAUGE

    4 Pages