ODAC® 310
4Pages

{{requestButtons}}

Catalog excerpts

ODAC® 310 - 1

Modular Single Axis Laser Measuring Head for Diameter, Width, Height. Measuring Field = 310 mm (12.2 in.). ODAC® 310 Modern single axis measuring head from the ODAC® laser measuring unit series. Highest accuracy, robustness, reliability and functionality distinguish all the laser heads from ZUMBACH. The ODAC® 310 is manufactured with a modular design. It is available with a support rail or as individual emitter and receiver parts when a maximum of flexibility is required to install the head in any position. The measuring head can also be installed in constricted confines or several emitter/ receiver pairs can be mounted in the same plane. ODAC® 310 models can be used in virtually every manufacturing process in the wire and cable industry, the plastics and rubber industry as well as the steel and metal industry. Known for precision, quality and ease of use the laser measuring heads from ZUMBACH are among the best of their class. The technological basis considered for these measuring heads is always of the latest cutting edge technology, with laser diodes as light sources combined with intelligent and powerful measured-value processors which facilitate a simple and flexible integration. Our long-standing experience as a pioneer of in-line measuring technology, combined with high production figures result in a product with an excellent priceperformance ratio. Amongst the outstanding features are features such as single scan calibration (CSS), single scan monitoring and high data rate output of up to 333* data packages per second. The measuring heads can be used with all line speeds. Vibrations during production have no noticeable influence on measurements. Main Advantages • Very high scan rate (measuring frequency) Standard: 1000/s, Version F: 2000/s • High precision measurement • High insensitivity to dirt and dust Flexible mounting With or without rail, different measuring distances Types of measurement 1 Diameter * Depending on the measuring head model, the number of transmitted measured values as well as the baud rate of the interface. Adaptive signal processing in the measuring units increase accuracy All the measuring heads of the ODAC® series have adaptive signal processing (patent DE3111356), which makes subsequent regular re-calibrations superfluous. Only in instances of component exchange or compliance to calibration regulations ISO 9001 etc. would re-calibration be required. All the relevant parameters for accuracy are continuously monitored by the measuring system and automatically compensated. This is valid in particular also for possible longterm changes of the behaviour of the scanner motor or the measuring electronics. Flexible communication integration • RS (-232 /-422 /-485) • PN (Profinet IO V2.3) • DP (Profibus DP) • EI (EtherNet/IP) • EN (Ethernet TCP/IP) • J (digital, for connection to USYS processors) Other types of measurement on request Special Applications Measurement of hot steel Ask for special data sheets on STEELMAST

Open the catalog to page 1
ODAC® 310 - 2

System Overviews ODAC® 310EN-RS (serial interface) Option: Local display LOC 01 Host RS-232 /-422 /-485 More applications with RS-485 interface and ANSI protocol Mains supply Option: Analogue interface Digital input for length detector Service Ethernet TCP/IP The built-in processor allows the acquisition and filtering of the measured values, as well as statistic functions, parameter selection and many other functions. The RS version communicates via the integrated Option: Display unit VISU-Touch RS interface with a higher level system, like USYS from ZUMBACH, host computer (or PLC). The...

Open the catalog to page 2
ODAC® 310 - 3

Ethernet cable Order Number Ethernet network cable cat. 6 S/FTP with RJ45 connectors. (XXX in the order number stands for: x 0.1 m, e.g. A15 608 8025 stands for 25 x 0.1 m and thus a cable that is 2.5 m long). Not for ODAC J versions. Delivered in a protection box, comprising: – Calibration standard holder – Calibration standard ø 6 and 200 mm – Certificate Other calibration standards on request. Power over Ethernet supply for devices that do not support PoE or a long Ethernet cable. Not for ODAC J versions. Is mounted directly on the measuring head. Requires connection cable #...

Open the catalog to page 3
ODAC® 310 - 4

Technical Data Version Model ODAC 310 Measurement Profile measurement JSx Same with synchronization input 310 mm (12.2 in.) Measuring field M 1) Min. object ø 1 mm (.04 in.) Scanning frestandard 1000 500 2000 – – quency scans/s F version Scanning speed 606 m/s (1988 ft./s); F version: 1212 m/s (3976 ft./s) 606 m/s (1988 ft./s) 6) Width of laser beam 8 mm (0.3 in.) 1.4 mm (.055 in.) see J/JP/JN Repeatability  250  ( 9.84 in.) mm 2.0 µm (0.1 s) (.00008 in.) 1.0 µm (1 s) (.00004 in.) 3.0 µm (0.1 s) (.00012 in.) 1.5 µm (1 s) (.00006 in.) (3 σ) at measur-   500 mm (19.69 in.) 2.5 µm (0.1 s)...

Open the catalog to page 4

All ZUMBACH Electronic AG catalogs and technical brochures

  1. KW 13/33TRIO

    4 Pages

  2. UMAC® CI

    2 Pages

  3. ODAC® 34XY

    4 Pages

  4. ODAC® 64XY

    4 Pages

  5. ODAC® 14XY

    4 Pages

  6. CELLMASTER®

    4 Pages

  7. ODAC-USYS

    6 Pages

  8. CAPAC® HS

    4 Pages

  9. ODEX® 10

    4 Pages

  10. RAYEX® D XT

    6 Pages

  11. RAYEX® S

    4 Pages

  12. USYS Touch

    4 Pages

  13. USYS IPCe

    6 Pages

  14. USYS 200

    4 Pages

  15. ODAC® 110XY

    4 Pages

  16. ODAC® 550

    4 Pages

  17. ODAC® 230

    4 Pages

  18. ODAC® 160

    4 Pages

  19. ODAC® 100

    4 Pages

  20. ODAC® 60J

    4 Pages

  21. VISU-Touch

    1 Pages

  22. USYS 20

    4 Pages

  23. BENDCHECK

    4 Pages

  24. DVO 2

    2 Pages

  25. DVW 1

    2 Pages

  26. AUTAC 300

    2 Pages

  27. ECOGAUGE

    4 Pages