ORC MODULE ZE - 30 - ULH
6Pages

{{requestButtons}}

Catalog excerpts

ORC MODULE ZE - 30 - ULH - 1

Product Sheet Energy Production

Open the catalog to page 1
ORC MODULE ZE - 30 - ULH - 2

PLANT TECHNOLOGY The structure of the proposed plant is based on the so-called low-temperature organic Rankine cycle (LT-ORC), and may be summed up by the diagram in Figure 1 1. A heat source [1] generates heat, which is conveyed through a vector fluid circulating into a closed loop to one or more primary heat exchangers, usually a preheater and an evaporator [2], where said heat is transferred from the vector fluid to the working fluid fluid. The working fluid - a low-boiling, biodegradable, non toxic liquid when at room temperature - boils in the evaporator at a temperature far lower than...

Open the catalog to page 2
ORC MODULE ZE - 30 - ULH - 3

INNOVATION Independently designed and manufactured using the most advanced technologies in finite elements and fluid-dynamics analysis (CFD/CFX), the ZE turbogenerators are designed from scratch to operate in a low-temperature organic Rankine cycle which uses a special working fluid that offers better performances and several advances over traditional steam turbines: • Low operational temperature which allow our systems to tap even low-grade heat sources; • High condensation temperature which may allow the use of simple air-cooled condensers; • Totally dry working fluid which means no...

Open the catalog to page 3
ORC MODULE ZE - 30 - ULH - 4

CIRCUIT COMPONENTS Recirculation Pump High-Speed Turbine Synchronous Electric Generator Power Converter Main Grid PROCESS DATA WORKING FLUID Type Mixture of environment-friendly, non-toxic, non-flammable HFCs Working Temperature Condensation Temperature Working Pressure HEAT EXCHANGER Type Brazed plate 30 bar (Nominal) / 39 bar (Test) /225 bar (Burst)

Open the catalog to page 4
ORC MODULE ZE - 30 - ULH - 5

PREHEATER + EVAPORATOR Total Thermal Power Input Vector Fluid Vector Fluid Temperature (input/output) Vector Fluid Flow Rate Power Output CONDENSER Thermal Dissipation Power Condenser Cooling Water Temperature (in/out) Condenser Circuit Flow TURBINE Type Single-stage radial inflow turbine w/fixed nozzles, directly coupled to the generator shaft Operating Temperature (input/output) Stage Pressure Machined steel (body) / Aluminium alloy (impeller) Speed Control Feedback loop on the generator current output Sealed labyrinth on impeller back and optionally at generator interface. Environmental...

Open the catalog to page 5
ORC MODULE ZE - 30 - ULH - 6

ZE-30-ULH DIMENSIONI SKID The ORC module is supplied mounted on a self-supporting frame (“skid”) hosting all module components, ready to be connected to heat source and heatsink. Where necessary, this skid is capable of fitting inside a standard 20” container for shipping. Skid weight and dimensions are listed on the left and below. Please keep in mind that the skid ideally requires at least 1.5 meters of free space on all sides for easy maintenance access. Zuccato Energia, as system developer and manufacturer, may also upon request design and build the module with custom dimensions and...

Open the catalog to page 6