Zolix Spectroscopy Catalog
57Pages

{{requestButtons}}

Catalog excerpts

Zolix Spectroscopy Catalog - 1

To be the worldwide leader in manufacturing high performance light measurement instruments Light Sources: A variety of different light sources Photodetector: Spectral coverage from Zolix Instruments Co.,Ltd. UV-VIS-IR spectrum

Open the catalog to page 1
Zolix Spectroscopy Catalog - 2

CONTENTS 02 UVRaman-100 UV Resonance Raman Spectrograph 06 DSR 100 Detector Responsivity Measurement System 09 GaiaField ground target large range scanning hyperspectral imaging system 13 GaiaSorter Hyperspectral Sorting System 16 Monochromator, Spectrographs 24 SGM 100 Spectrograph 28 Light Source for Spectroscopy 31 Tunable monochromatic light source 37 Detector Data Acquisition 54 Sample Chambers E-MAIL: info@zolix.com.cn TEL: +86 10 56370168 http://www.zolix.com.cn

Open the catalog to page 2
Zolix Spectroscopy Catalog - 3

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers UVRaman-100 UV Resonance Raman Spectrograph New generation UV Resonance Raman Spectrograph Chinese Academician Can LI, Dalian Institute of Chemical Physics (DICP), Chinese Academy of Sciences (CAS), and his study group developed the first UV Resonance Raman Spectrograph, received the CAS second prize and the second prize of national innovation. On April 8th, established the Modern Instruments Joint Laboratory with ZOLIX, which facilitates a faster transition from research to actual...

Open the catalog to page 3
Zolix Spectroscopy Catalog - 4

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers UVRaman-100 UV Resonance Raman Spectrograph UV Raman Spectrum testing the ultra-low content < Ti in the molecular sieve skeleton. UV Raman Spectrum characterization of different types UV Raman Spectrum in-situ research molecular sieve synthesis mechanism. Application directions: ♦ Catalysis ♦ Biochemistry .Life Sciences ♦ Materials science, polymer science ♦ nano science ♦Optoelectronic Materials E-MAIL: info@zolix.com.cn TEL: +86 10 56370168 http://www.zollx.com.cn

Open the catalog to page 4
Zolix Spectroscopy Catalog - 5

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers UVRaman-100 UV Resonance Raman Spectrograph Appendix 1: UV Raman and resonance Raman Principle and Application The problems of fluorescence interference and the low sensitivity block the extensive application of conventional Raman spectroscopy. But the above problems have been solved with the development of UV Raman spectroscopy in recent years. The advent and development of UV Raman spectroscopy technology extends the scope of UV Raman spectroscopy application. On the right is the...

Open the catalog to page 5
Zolix Spectroscopy Catalog - 6

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers UVRaman-100 UV Resonance Raman Spectrograph Appendix 2: experiment examples Study of molecular sieve Synthesis mechanism ♦ Ultra-low content of isolated transition metal ion( Ti-MCM-41) in the micro-mesoporous materials skeleton can be identified by UV resonance Raman spectroscopy reliably and accurately. surface phase structure UV Resonance Raman Spectroscopy application in Catalysis Research ♦ Using the characteristics of UV Raman which can avoid the fluorescence and increase...

Open the catalog to page 6
Zolix Spectroscopy Catalog - 7

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers DSR100 Detector Responsivity Measurement System DSR100 Detector Responsivity Measurement System introduction Photodetector is the sensor that could convert the optical radiation signal to the electrical signal, which is made from photoemission material. Most of the photodetectors have strong spectral selectivity in a certain Spectrum area. Therefore, for one photodetector different wavelengths have different spectral responsivity. The spectral responsivity is an important parameter...

Open the catalog to page 7
Zolix Spectroscopy Catalog - 8

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers DSR100 Detector Responsivity Measurement System ♦ Perfect reflection optical design, optimization of spot quality Different photodetectors have different spectrum response range, so the perfect Detector Responsivity Measurement System has the wide spectral range and can be widely used for different photodetectors. The system designed in perfect reflection optical has better beam quality and spot uniformity than the system with transmission optical design. In the transmission optical...

Open the catalog to page 8
Zolix Spectroscopy Catalog - 9

UVRarnan-100 DSR100 GaiaField GaiaSorter Chameleon Spectrographs SGM100 Light Source Detector Sample Chambers DSR100 Detector Responsivity Measurement System ♦ High stability light source, reducing the background noise. Though the modulation method could reduce the impact of stray light and the background noise on the measurement, the fluctuation of light source is still impossible to eliminate. So in the system designed in modulation, the stability of light source is the main source for system noise. DSR100 adopt the high stability light source to keep the system high repeatability. The...

Open the catalog to page 9
Zolix Spectroscopy Catalog - 10

SGM 100 Light Source Detector Sample Chambers GaiaField ground target large range scanning hyperspectral imaging system GaiaField ground target large range scanning hyperspectral imaging system, that is the ground remote sensor which uses the advanced hyperspectral imaging technology. The core of the system is one imaging spectrograph, which could make the hyperspectral scanning for long distance, large range target object, and get the object imaging and spectrum information. Widely used in target recognition, camouflage and counter camouflage research application field and ground objects...

Open the catalog to page 10
Zolix Spectroscopy Catalog - 11

SGM 100 Light Source Detector Sample Chambers GaiaField ground target large range scanning hyperspectral imaging system Portable design, equipped with long life battery, long time outdoor measurement GaiaField ground targets large range scanning hyperspectral imager using portable design, easy to carry, also equipped with long life rechargeable lithium ion battery, up to 12 hours. Reflectivity measurement model GaiaField ground target large range scanning hyperspectral imaging system is based on the natural light environment, for the reflectivity measurement of vegetation, lakes, oceans,...

Open the catalog to page 11

All Zolix Instruments CO. catalogs and technical brochures

  1. OmniPL