9201100

9201100

9201100

Product catalog summary
Electromagnetic Valve Overview
The ZITA BG electromagnetic valve, type 9201100.0900, is a normally closed, direct effect, 2/2 way valve with a G 1/8 connection. It is designed for remote control and regulation in automatic systems across various industries such as machine building, energy, and chemical sectors. The valve operates on a digital principle with two states: active (electrical signal supplied) and idle (no voltage supplied).
Technical Specifications
  • Working Pressure: 0 to 40 Bars
  • Maximum Pressure: 40 Bars
  • Working Fluid: Water, air, gas, petrol products
  • Temperature Range: Ambient: -30°C to +60°C; Fluid: -30°C to +80°C
  • Viscosity: Max 25 sSt
  • Gaskets: NBR (Nitrile Butadiene Rubber)
Construction
  • Body: Brass
  • Tongue: Stainless steel
  • Internal Parts: Brass
  • Spring: Stainless steel
  • Seat: Stainless steel
Electrical Features
  • Electromagnet Conductor: Copper
  • Coil Insulation Class: F
  • Protection Degree: IP 65
  • Standard Voltages: 12V, 24V, 48V, 110V, 220V DC/AC
Installation and Operation
  • Valves can be installed arbitrarily and do not have installation openings.
  • Pipe connection threading conforms to ISO 228/1 and ISO 7/1.
  • Installation instructions are provided with each valve.
  • Ensure fluid flow direction matches the valve marking.
  • Use a filter for contaminated fluids.
Maintenance and Service
  • No special service required; ensure leak tightness and proper cable sealing.
  • Protection degree IP 65 must be maintained.
Storage and Transportation
  • Store in dry, ventilated areas at -25°C to +55°C with up to 80% humidity.
  • Transport in packaging at -20°C to +50°C; acclimate for two hours before use.
Guarantees
The company offers a 24-month guarantee for replacement or repair if the product does not meet company standards, provided all handling instructions are followed.
See more

Catalog excerpts

9201100-1

ZITA BG ELECTROMAGNETIC (SOLENOID) VALVE Type 9201100.0900 Normally closed; direct effect; G 1/8 ; 2/2 way PRINCIPLE OF OPERATION The electromagnetic valves of this type are devices providing by means of electromagnetic drive control of flowing and stopping of fluid on the pipelines. In the automatic regulation systems they serve as relay bodies for remote control and regulation. The electromagnetic valves are intended for integration in automatic systems in machine building, energy, chemical industry etc. The electromagnetic valves of these series are two-way, twopositioned, normally closed, with direct effect. The valves have a certain direction of fluid flow, which is indicated on the article. Many of the electromagnetic valves are operating on digital principle. Because of this they have two states – when to the electromagnet (coil) is supplied electrical signal and when the valves are in idle state (no voltage is supplied). The valves function is determined of their state in which they are at the moment. GENERAL TECHNICAL FEATURES Working pressure (∆Р) from 0 to 40 Bars Maximum permissible pressure 40 Bars Ambient temperature (0С) From minus 30 to +60 Viscosity of the working fluid maximum 25 sSt (mm2/с) Time for valve bedding-in Up to 0,2 seconds (at air DP = 40 bars) Working fluid water; air; gas; petrol products Temperature range of the working fluid(0С) From minus 30 to +80 Gaskets NBR (Nitrile Butadiene Rubber) CONSTRUCTION 1. Body 2. Tongue 3. Internal parts 4. Spring 5. Seat 6. Gasket brass stainless steel brass stainless steel stainless steel NBR (other gasket on request) ELECTRICAL FEATURES Electromagnet conductor copper Coil insulation class F Protection degree IP 65 Coupling specification ISO 4400 Connection flat Standard voltages 12V, 24V, 48V, 110V, 220V DC/АС Specification for connection at degree of protection IP 65 Connector type DIN 43650-A Connector plug Blocking system bolts Maximum current 16 А

 Open the catalog to page 1
9201100-2

ZITA BG Installation On cable Nominal pressure 250 V Structure of batten terminals 2+РЕ Conformity with standard DIN 43650-A, ISO 4400 External conductor diameter from 6 to 9 mm Conductor section 1,5 mm2 SPECIFICATION Throughput capacity Connection dimensions Passage section Working pressure (Bar) Coil type MINIMUM Catalogue number The electromagnetic valves of this type may be installed arbitrarily. These valves do not have installation openings provided in the body. The pipe connection (G) standard threading in conformity with ISO 228/1 and ISO 7/1. Other connection – by order. Installation/operation...

 Open the catalog to page 2
9201100-3

ZITA BG REGULAR STORAGE The valves shall be stored in dry ventilated premises with temperature from minus 250С to plus 550С and relative humidity up to 80%. In the premises shall not be substances which would cause corrosion of parts. TRANSPORTATION The valves may be transported in package at temperature from -200С to +500С. After unpacking they should stay at least two hours at temperature from +50С to +400С before their operation. GUARANTEES The producing company undertakes for period of 24 months as of the date of dispatch by the company, to replace or repair the devices free of charge, if...

 Open the catalog to page 3

All ZITA BULGARIA catalogs and technical brochures

  1. AQASONIC

    2  Pages

  2. 0955503

    3  Pages

  3. 8020750

    4  Pages

  4. 2636000

    4  Pages

  5. 8022750

    4  Pages

  6. 8020850

    4  Pages

  7. 2637250

    4  Pages

  8. 9201800

    3  Pages

  9. 0955400

    3  Pages

  10. 0927700

    3  Pages

  11. 0955500

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.