E2000

E2000

E2000

Product catalog summary
Overview
The ZIROX Electronic Unit E2000 is designed for use with ZIROX oxygen probes, providing a comfortable and efficient way to record and process signals to determine oxygen concentration. It supports the probes with reference air supply, power, and heater control, while also monitoring probe resistance and signaling errors.

Key Features
  • Processes and displays ZIROX probe measurements.
  • Includes calibration and monitoring functions.
  • Outputs measurements via standard interfaces.
  • Offers process monitoring and customized solutions.
  • Optional automatic calibration function.

Technical Specifications
  • Signal Input: Cell and thermal voltage from ZIROX probes.
  • Range: 0 to 20.64 vol% O2, extendable to 100 vol% on request.
  • Accuracy: Relative error less than 5%.
  • Reference Gas Supply: Internal pump with flow monitoring.
  • Display: LCD dot-matrix.
  • Keypad: 6 membrane keys.
  • Digital Interface: RS232.
  • Output: Two potential-free current outputs (0/4-20 mA) or voltage output (0-5/10 V), with programmable limit values and alarm signaling.
  • Power Supply: 110-230 V, 50-60 Hz.
  • Dimensions: 300 × 300 × 120 mm.
  • Weight: Approximately 4 kg.
  • Protection Degree: IP65.
  • Operating Temperature: 0 to 50°C, 0 to 95% relative humidity.
  • Storage Temperature: -20 to -60°C, 0 to 95% relative humidity.

Additional Capabilities
In conditions with incomplete combustion (reducing conditions), the E2000 can calculate additional values such as air factor λ, dew point, H2O/H2 ratio, CO2/CO ratio, and concentrations of CO2 and H2O at water-gas equilibrium, provided the fuel gas composition is known.
See more

Catalog excerpts

E2000-1

ZIROX Electronic Unit E2000 Properties The electronic unit E2000 is a comfortable device for the use of ZIROX oxygen probes. The signals of ZIROX probes are recorded with the E2000, processed according to the NERNST equation to the oxygen concentration (normally in vol%) and generated via standard interfaces. The electronic unit E2000 supplies the probe with reference air via internal pump. Additionally, the E2000 realizes the power supply and the heater control for heated ZIROX probes. Furthermore, the probes are monitored by the E2000 with cyclical measurements of the cell resistance. An error message is signalized if necessary. The user can program two limit values (output via relay). If requested, the E2000 can be delivered with automatic calibration function. In incomplete burned gases (reducing conditions), more values can be calculated (air factor X, dew point, H2O/H2-ratio, CO2/CO-ratio, c(CO2) and c(H2O) at water-gas-equilibrium). Precondition: known fuel gas composition, e.g. C/H-ratio. Features • Signal processing and display of ZIROX probes measuring values • Calibration and monitoring function for ZIROX® probes • Measuring value output via standard interfaces • Process monitoring via standard interfaces • Customized solutions • Automatic calibration function (optional) ZIROX® Electronic Unit E2000 ZIROX GmbH - Am KappHberg 2t -17*89Greifswald T rv.-iii intoff'Jtirps clH1

 Open the catalog to page 1
E2000-2

adjustable (alternatively: voltage output 0.5/10 V) 2 programmable limit values (relay output) Alarm signalling (relay output)

 Open the catalog to page 2