Overview: This document provides technical specifications and operational guidelines for transformer-based controllers designed for single-phase (1~) motors, specifically for 5-step voltage controllable fans. The controllers are suitable for applications such as heat exchangers, hoods, and room ventilation.
Specifications:
  • Line Voltage: 1~ 230 V, 50/60 Hz
  • Output Voltage Steps: 65 V, 110 V, 135 V, 170 V, 230 V
  • Maximum Load for Additional Contact: 1 A
  • Maximum Ambient Temperature: +40°C
  • Protection Rating: IP54 for most models, IP21 for R-E-12
Features:
  • Manual 5-step speed control for one or more fans
  • Integrated power-on lamp
  • Automatic restart after power failure
  • Recommendation for separate motor protection device (S-ET10) for motors with thermocontacts
Model Variants and Technical Data:
  • R-E-1.5G: 1.5 A, Max. Line Fuse T4 A, Approx. Heat Dissipation 20 W, Weight 2.0 kg
  • R-E-2G: 2.0 A, Max. Line Fuse T4 A, Approx. Heat Dissipation 20 W, Weight 2.2 kg
  • R-E-3.5G: 3.5 A, Max. Line Fuse T4 A, Approx. Heat Dissipation 30 W, Weight 3.5 kg
  • R-E-6G: 6.0 A, Max. Line Fuse T8 A, Approx. Heat Dissipation 35 W, Weight 5.0 kg
  • R-E-7.5G: 7.5 A, Max. Line Fuse T8 A, Approx. Heat Dissipation 40 W, Weight 6.0 kg
  • R-E-9G: 9.0 A, Max. Line Fuse T16 A, Approx. Heat Dissipation 50 W, Weight 10.5 kg
  • R-E-12: 12.0 A, Max. Line Fuse T20 A, Approx. Heat Dissipation 80 W, Weight 10.5 kg
  • R-E-14G: 14.0 A, Max. Line Fuse T20 A, Approx. Heat Dissipation 105 W, Weight 12.5 kg
Installation and Safety:
  • Ensure the main supply is switched off before removing the cover.
  • Connection diagrams are provided for different models.
Contact Information: Ziehl-Abegg AG, Heinz-Ziehl-Straße, D-74653 Künzelsau, Tel.: +49 (0) 7940 16-0, Fax: +49 (0) 7940 16-504, Email: [email protected], Website: http://www.ziehl-abegg.de
See more

Catalog excerpts

R-E1.5...14G -1

R-TIL02_54_R-E_GB (01.02.06) Subjekt to technical modification 8. 8.1.1-GB Transformer based controller for 1~ motors 5-step controller for voltage controllable fans Type: R-E-1.5 ... 14G Examples of applications for controlling 1~ fans in 5-steps Manual 5-step speed change-over of one or more 1~ fans e. g. in: heat exchangers (as warm-air heaters), hoods, ventilation of rooms. The additional voltage output 230 V (terminals 1 and 2) is activated, if fan runs at step 1, 2, 3, 4 or 5. It can be used e. g. for a signal lamp or damper control. Equipment Enclosed version IP 54 Transformer based controllers for voltage controllable 1~ fans • 5-step switch for manual speed control • Integrated power on lamp • Automatic switch on after power failure • For motors with thermocontacts we recommend that each fan is equipped with a separate motor protection device type S-ET10 (see data sheet 3.1.1) Technical data - Line voltage 1~ 230 V, 50/60 Hz - Output voltage 65 V - 110 V - 135 V - 170 V - 230 V - Max. load additional contact 1 A - Max. ambient temperature + 40° C - R-E-1.5.. 6: plastic housing light grey RAL 7035 ·R-E-1.5G: all-ABS ·R-E-2/3.5/6G: top ABS, bottom Wellamid - R-E-7.5G.. R-E-14G: housing top ABS plastic light grey RAL7035 bottom aluminium die casting Type Part-No. Rated current Max. line fuse Max. heat dissipation Protection Weight R-E-1.5G 302001 1.5 A T4 A approx. 20 W IP54 2.0 kg R-E-2G 302047 2.0 A T4 A approx. 20 W IP54 2.2 kg R-E-3.5G 302048 3.5 A T4 A approx. 30 W IP54 3.5 kg R-E-6G 302049 6.0 A T8 A approx. 35 W IP54 5.0 kg R-E-7.5G 302053 7.5 A T8 A approx. 40 W IP54 6.0 kg R-E-9G 302055 9.0 A T16 A approx. 50 W IP54 10.5 kg R-E-12 302056 12.0 A T20 A approx. 80 W IP21 10.5 kg R-E-14G 302057 14.0 A T20 A approx. 105 W IP54 12.5 kg Dimension sheet [mm] Connection diagram R-E-1.5G R-E-7.5G (R-E-12/14G) R-E-2/ 3.5 / 6 G Ziehl-Abegg AG Heinz-Ziehl-Straße D-74653 Künzelsau Tel.: +49 (0) 7940 16-0 Fax: +49 (0) 7940 16-504 [email protected] http://www.ziehl-abegg.de IP54 IP54 IP54 IP54 IP21 R-E-1.5G R-E-2/3.5/6G R-E-7.5G R-E-9G / R-E-14G R-E-12 Switch off the main supply before removing the cover! Vor Öffnen des Deckels Gerät spannungsfrei schalten! R-E-... N L1 PE N L1 1~ Motor ohne Thermokontakte without thermocontacts sans thermocontacts utan termokontakter M 1~ PE U1 U2 U1 U2 1 2 L N SR148K01 21.06.2004 Kontaktbelastung contact rating pouvoir de coupure kontaktbelastning 230VAC max. 1A Netz / line / secteur Nätanslutning 1~ 230V 50/60Hz