Catalog excerpts
Movement by Perfection The Royal League in ventilation, control and drive technology ECblue The energy saver amongst fans
Open the catalog to page 1No one can get passed the Royal League Z I E H L - A B E G G s t a n d s f o r m o v e m e n t b y p e r f e c tion in the ventilation technology, control technology and drive technology sectors for more than 100 years. What started with the invention of the first external rotor motor by Emil Ziehl is now being carried on at the company’s sites around the world. We are the pioneers, masterminds and developers of technologies for the future which more than satisfy all demands to preserve an environment worth living in and to meet all our customers’ requirements and wishes. Think ahead to the...
Open the catalog to page 3From fans and motors to matching control technology Our unique selling point – your advantage What is important to us is to correctly match our systems to your exact needs. Be it refrigeration, air conditioning, use in manufacturing processes or anywhere else - we reliably move air wherever it is required and at the right time. At the headquarters in Künzelsau more than 100 engineers and technicians work in one of the most modern technology centres of this kind. We supply the highest quality standards with the world‘s largest air and noise testbench for fans, which can completely mask...
Open the catalog to page 4The principle Ingeniously simple – highly efficient – exceedingly reliable ECblue The new economic solution Ingeniously simple functionality Compact, cutting-edge technology, user-friendly and simple – these are the main criteria we set for the development of the ECblue series. Meet ECblue and convince yourself of the result! Maximum efficiency – Minimum power consumption Nowadays, saving energy is more important than ever. Energy costs are exploding; the global climate is changing. Fans with ECblue technology will help lower your operating costs. Our environment will also appreciate the...
Open the catalog to page 6EC technology history Since the middle of the 80’s, ZIEHL-ABEGG has been performing pioneering work in the development and manufacturing of efficient EC external rotor motors for fans. Nearly 30 years later, a new era is dawning in EC technology: ECblue. ECblue is ZIEHL-ABEGG’s third generation of EC motors. This latest EC technology is setting new standards for control, efficiency and reliability. EC means electronically commutated. EC motors are synchronous electric motors which have electronic commutation systems, rather than mechanical commutators and brushes. The speed of the fans or...
Open the catalog to page 8ECblue – Efficient Presently, saving energy is more important than ever. Energy costs are exploding; the global climate is changing. Fans with ECblue technology will help lower your operating costs. Our environment will also appreciate the low power consumption of the ECblue fans – after all, the cleanest energy is the energy that doesn’t need to be generated in the first place! In 2005 the European Union passed the EuP Directive (Energy using Products Directive), which was replaced in 2009 by the ErP Directive (Energy related Products Directive). With this directive the scope was enlarged...
Open the catalog to page 10ECblue – Reliable Premium Quality 10 0% of fans are tested and the test data rec orded before they leave the factor y. En c a p s u l a t i o n Enc apsulation is a proc ess of f illing a c omplete electronic assembly with a solid c ompound for resistanc e to shock and vibration, and for exclusion of moisture and c or rosive agents. It also provides much more protection against dust, humidit y and aggressive environments. Bet ter Protection results in another advantage, and that is power densit y. E x tending the life of the electronic s and making it more robust. ZIEHL-ABEGG is testing the...
Open the catalog to page 11ECblue – Flexible Add on Modules Wireless programming – standard in ECblue With their modular c onstr uction, the functions in the EC116 and EC152 motor frame size ECblue fans c an be expanded by simply plugging in additional modules. The add - on modu les c an be tailor- made to c over var ious applic ations. This means the ECblue fans have precisely the functions you need. Nothing more and nothing less. Even if the require ments plac ed on the ECblue happen to change later on – no problem. When considering the functionality of the motors, our engineers have taken things one step further....
Open the catalog to page 12ECblue – Simple ECblue inside - More than you can see at first sight Power electronics with wide voltage range: Integrated motor controller Provide controlled power to the motor 1~ 3~ 3~ 3~ Motor protection Intelligent motor protection devices protect the motor 200…277V, 200…240V, 380…480V, 200...480V, 50/60Hz 50/60Hz 50/60Hz 50/60Hz on request One motor for all your applications - worldwide! Temperature management Promote reliability under the worst operation conditions For the North American market UL listed products available. Under/over voltage protection Indicated by status LED Power...
Open the catalog to page 13ECblue – High efficiency low noise A FE2owlet has a noise level around 4 5 dB* *FE2owlet (FN080) calculated at 5m distance at full speed 25 dB Nature outside (feels totally quiet) 14 30 dB Whispering 40 dB Hum of a refrigerator 60 dB Normal conversation w w w.ziehl - abegg.c om
Open the catalog to page 14The increase of 3 dB doubles the felt noise level Ziehl-Abegg AG has one of the best noise testrooms world wide. The testroom is AMCA and TÜV certificated. Inside, when all doors are closed, background noise is below 20 dB. It feels abnormally silent. Airflow 100% 50% 25% Switching complete fans on/off X dB full speed noise 4 fans on - 3 dB (2 fans on) - 6 dB (1 fan on) Speed control of all fans X dB full speed noise ~ 15 dB (50% speed) ~ 30 dB (25% speed) ECblue fans are speed controllable. In the chart you can see the difference between "switching off" and "speed control" with regard to...
Open the catalog to page 15How can a speed controlled fan help you to increase your system efficiency? Calculation example 5 0% air f low is needed in a 10 fan condenser ar ray, shut down 5 fans Shut ting down 5 fans leads to a power c onsumption of 5 kW P = (5 * 1 kW ) + (5 * 0 kW ) = 5 kW Reduce all fans to 5 0% The reduction of the fans leads to a power consumption of 1,25 kW Basic dat as: 1 fan has a power c onsumption of 1 kW at 10 0% Law of power c onsumption dependant on speed n n 3 P1 = 10 kW; n1 = 10 0 0 r pm; n2 = 50 0 r pm P = (10 kW / (10 0 0 rpm/50 0 r pm) ³) = (10 kW/8) = 1, 25 kW 75% lower power...
Open the catalog to page 16All ZIEHL-ABEGG catalogs and technical brochures
-
Fans for transformer cooling
260 Pages
-
Fans for railroad engineering
334 Pages
-
Fans for heat pumps
4 Pages
-
ECblue high-efficency motors
14 Pages
-
FE2owlet
4 Pages
-
Axial fans main catalogue_2016
544 Pages
-
ZAwheel
12 Pages
-
ZAdyn 4c
4 Pages
-
EVAC 3
8 Pages
-
MAXvent owlet
10 Pages
-
Product range
4 Pages
-
Axial Fans Main Catalogue FE2owlet
144 Pages
-
Flyer Fans for wind turbines
5 Pages
-
Flyer Cpro ZAmid
4 Pages
-
Drive technology
112 Pages
-
COMPLETE PROGRAMME
24 Pages
Archived catalogs
-
FE2owlet-50Hz - part 2 - FN040
11 Pages
-
DL2.5 Controllers
38 Pages
-
FC100, FC125
38 Pages
-
A01 60 Hz North America FB-Series
24 Pages
-
A01 60 Hz North America FE-Series
30 Pages
-
R-DK...KT(G)
2 Pages
-
R-D-1...7
1 Pages
-
RASE9G
1 Pages
-
RAE-2/4/7G
1 Pages
-
R-E1.5...14G
1 Pages