1. Catalogs
  2. ZIEHL-ABEGG
  3. Axial fans main catalogue_2016
video corpo

Axial fans main catalogue_2016

Axial fans main catalogue_2016
1 / 196 PagesView full catalog

Axial fans main catalogue_2016

Product catalog summary
Specifications:
The document details various fan models, each identified by a unique code, such as FC080-6D_.6K.A7. Specifications include motor technology, rated voltage, frequency, input power, and efficiency. Fans are designed for both single-phase and three-phase AC, with protection class IP54 and thermal contact motor protection.

Procedures:
Characteristic curves are measured according to ISO 5801 standards, showing performance metrics like air flow direction, design types (flange ring or square full bell mouth), and sound power levels. Connection diagrams for electrical setup are also included.

Standards and Norms:
The fans comply with ErP 2015 and CE standards, ensuring energy efficiency and safety. Efficiency data is provided with actual and target values, highlighting performance against regulatory benchmarks.

Recommendations:
It is recommended to use specific motor protection units and electronic voltage controllers to optimize performance. The document advises on permissible ambient temperature ranges for operation to ensure fan longevity and reliability.

Key Data from Tables and Graphs:
Tables and graphs present detailed performance data, including operating points, current, input power, speed, and sound power levels at various voltages. This data is crucial for selecting the appropriate fan model based on specific application requirements.

Critical Information:
- Rated voltage and frequency: 230/400 V, 50 Hz
- Input power: Ranges from 0.89 kW to 2.90 kW
- Efficiency: Up to 38.0%
- Protection class: IP54
- Compliance: ErP 2015, CE
- Operating temperature: -40°C to 70°C
See more

Catalog excerpts

Axial fans main catalogue_2016-1

A x i a l Fa n s Main Catalogue 2016 Edition

 Open the catalog to page 1
Axial fans main catalogue_2016-3

Blades made of aluminium resp., steel optimised for short bell mouth Profiled blades made of aluminium, optimised for full bell mouth Connection diagram

 Open the catalog to page 3
Axial fans main catalogue_2016-4

Expertise in ventilationErP directive With the Kyoto protocol, the European Union pledged to reduce CO2 emissions by at least 20 per cent by the year 2020. One measure for achieving this is the ErP directive for improved energy efficiency and general environmental compatibility of electrical equipment - also known in Germany as the Eco Design directive. It supports a resource-friendly and energy-efficient product design. With the implementation of the ErP directive, stricter efficiency requirements for fans in the output range from 125Wto 500 kW apply since 2013 and 2015 in two stages. A further...

 Open the catalog to page 4
Axial fans main catalogue_2016-5

Information Technical description FB, FC Optimised for short bell mouth applications Two airflow directions possible Three blade angles 100 % speed control Primarily refrigeration / heating, in short bell mouth FB fans are primarily used in equipment with short bell mouth, see installation examples section. Profiled die cast aluminium blades 0 315 ... 1250 mm Optimised for full nozzle 100 % speed control Air conditioning and refrigeration, agriculture, transformerand rolling stock cooling, wood drying, industry, engineering The FC series of fans with die cast aluminium blades deliver exceptionally...

 Open the catalog to page 5
Axial fans main catalogue_2016-7

Product overview Quick selection Page 8

 Open the catalog to page 7
Axial fans main catalogue_2016-8

FB, AC- technology Quick selection Voltage Number of poles Type Airflow direction ErP Page 200 * with ZIEHL-ABEGG frequency inverter - FB040-4EK.2F.V4L

 Open the catalog to page 8
Axial fans main catalogue_2016-9

FB, AC- technology Quick selection Operating range♦ Max. static pressure increase ApsF [Pa] FB025-2E_ .WC._5 FB025-4E_ .WA._5

 Open the catalog to page 9
Axial fans main catalogue_2016-10

'HVLJQ/URXQGIXOOEHOOPRXWKJXDUGJULOOH VXFWLRQVLGH 'HVLJQ'D[LDOEROWHGVXVSHQVLRQIRUIXOO EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH 'HVLJQ:D[LDOEROWHGPRXQWLQJIRUVKRUW EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH

 Open the catalog to page 10
Axial fans main catalogue_2016-11

Performance data Suction side sound power level Operating point Current Input power *rated data Fan ordering information Airflow direction A X Airflow direction V W (guard grille suction D (guard grille suction L (guard grille suction K (guard grille pressure I (guard grille pressure H (guard grille pressure side) side) side) side) side) side) Control technology Frequency inverter Fcontrol 1~ Design K - axial bolted, mounted for short bell mouth, guard grille pressure side Design I - axial bolted, mounting for bell mouth flange, guard grille pressure side Design H - pipe sockets with a flange,...

 Open the catalog to page 11
Axial fans main catalogue_2016-12

'LPHQVLRQVPP $LUIORZGLUHFWLRQ$ 'HVLJQ/URXQGIXOOEHOOPRXWKJXDUGJULOOH VXFWLRQVLGH 'HVLJQ'D[LDOEROWHGVXVSHQVLRQIRUIXOO EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH 'HVLJQ:D[LDOEROWHGPRXQWLQJIRUVKRUW EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH

 Open the catalog to page 12
Axial fans main catalogue_2016-13

’rated data Airflow direction A T Airflow direction V W (guard grille suction D (guard grille suction L (guard grille suction K (guard grille pressure I (guard grille pressure H (guard grille pressure side) side) side) side) side) side) Control technology Frequency inverter Fcontrol 1~ Design K - axial bolted, mounted for short bell mouth, guard grille pressure side Design I - axial bolted, mounting for bell mouth flange, guard grille pressure side Design H - pipe sockets with a flange, guard grille pressure side

 Open the catalog to page 13
Axial fans main catalogue_2016-14

Characteristic curve Description Motor technology: AC Rated voltage UN: 1~ 230 V* Rated frequency fN: 50 Hz* (60Hz data available) Starting current lA: 0.95 A Service capacitor C400V: 4.0 pF Thermal class: THCL155* Min. permitted ambient temperature t : -40 °C Max. permitted ambient temperature t : 75°C Electrical connection: Supply cable variable 45 cm Motor protection: thermal contact Blades: Steel, powder-coated, jet black Rotor: Aluminium, 1 coat paint, ultramarine blue Not subject to the regulations of ErP directive (P,< 125 W) * Rated data Measured in full bell mouth without guard grille...

 Open the catalog to page 14
Axial fans main catalogue_2016-15

’rated data Airflow direction A T Airflow direction V W (guard grille suction D (guard grille suction L (guard grille suction K (guard grille pressure I (guard grille pressure H (guard grille pressure side) side) side) side) side) side) Control technology Frequency inverter Fcontrol 1~ Design K - axial bolted, mounted for short bell mouth, guard grille pressure side Design I - axial bolted, mounting for bell mouth flange, guard grille pressure side Design H - pipe sockets with a flange, guard grille pressure side

 Open the catalog to page 15
Axial fans main catalogue_2016-16

'LPHQVLRQVPP $LUIORZGLUHFWLRQ$ 'HVLJQ/URXQGIXOOEHOOPRXWKJXDUGJULOOH VXFWLRQVLGH 'HVLJQ'D[LDOEROWHGVXVSHQVLRQIRUIXOO EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH 'HVLJQ:D[LDOEROWHGPRXQWLQJIRUVKRUW EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH

 Open the catalog to page 16
Axial fans main catalogue_2016-17

’rated data Airflow direction A T Airflow direction V W (guard grille suction D (guard grille suction L (guard grille suction K (guard grille pressure I (guard grille pressure H (guard grille pressure side) side) side) side) side) side) Control technology Frequency inverter Fcontrol 1~ Design K - axial bolted, mounted for short bell mouth, guard grille pressure side Design I - axial bolted, mounting for bell mouth flange, guard grille pressure side Design H - pipe sockets with a flange, guard grille pressure side

 Open the catalog to page 17
Axial fans main catalogue_2016-18

'LPHQVLRQVPP $LUIORZGLUHFWLRQ$ 'HVLJQ/URXQGIXOOEHOOPRXWKJXDUGJULOOH VXFWLRQVLGH 'HVLJQ'D[LDOEROWHGVXVSHQVLRQIRUIXOO EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH 'HVLJQ:D[LDOEROWHGPRXQWLQJIRUVKRUW EHOOPRXWKJXDUGJULOOHVXFWLRQVLGH

 Open the catalog to page 18
Axial fans main catalogue_2016-19

’rated data Airflow direction A T Airflow direction V W (guard grille suction D (guard grille suction L (guard grille suction K (guard grille pressure I (guard grille pressure H (guard grille pressure side) side) side) side) side) side) Control technology Frequency inverter Fcontrol 1~ Design K - axial bolted, mounted for short bell mouth, guard grille pressure side Design I - axial bolted, mounting for bell mouth flange, guard grille pressure side Design H - pipe sockets with a flange, guard grille pressure side

 Open the catalog to page 19
Axial fans main catalogue_2016-20

Characteristic curve Description Motor technology: AC Rated voltage UN: 1~ 230 V* Rated frequency fN: 50 Hz* (60Hz data available) Input power Pp 0.15 kW* Starting current lA: 1.10A Current increase Al: 0 % Service capacitor C400V: 5.0 pF Thermal class: THCL155* Min. permitted ambient temperature t : -40 °C Max. permitted ambient temperature t : 65°C Electrical connection: Supply cable variable 45 cm Motor protection: thermal contact Blades: Steel, powder-coated, jet black Rotor: Aluminium, 1 coat paint, ultramarine blue Measured in full bell mouth without guard grille in installation type A...

 Open the catalog to page 20
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.