© ZIEHL-ABEGG SE - 00705985 - EN - MA - 04/2018 -1.000 - Klunker & Ewald - This catalogue contains information for your guidance. No guarantee is provided with regard to the accuracy of all information and no legal claims may be derived from this. Reproduction of this information, or extracts thereof, is permitted only with written approval. ZIEHL- A BEGG SE Heinz-Ziehl - Straße D -74653 Künzelsau +49 79 40 16 - 0 info@ ziehl - abegg.c om w w w.ziehl - abegg.c om Fans and Control Technology The Royal League in ventilation, control and drive technology
Open the catalog to page 1High pressure fans Size 630 Addendum Fans and Control Technology for agriculture 04/2018 FE2owlet for three phase alternating current, 4-4 pole Characteristic curve Motor technology: AC Rated voltage UN: 3~ 400 V (∆/Y) ±10 %* Rated frequency fN: 50 Hz* (60Hz data available) Input power P1: 1.75/1.35 kW* Rated current IN: 3.70/2.20 A* Rated speed nN: 1400/1210 min-1* Starting current IA: 20.00 / 6.50 A Current increase ∆I: 5 % Thermal class: THCL155* Min. permitted ambient temperature tR(min): -40 °C Max. permitted ambient temperature tR(max): 70 °C Electrical connection: Terminal box Number of...
Open the catalog to page 2Addendum Fans and Control Technology for agriculture 04/2018 High pressure fans Size 630 Performance data Type Characteris Connection Voltage Operating Current Input power Speed Acoustic Specific pressure power Fan ordering informationAirflow direction A Q (guard grille suction Q (guard grille suction Design T (without guard grille) Q (without guard grille) sid'e) Q (without guard grille) side) Article no. 177602 Wall ring plate Weight kg 25.10 Wall ring plate made of Wall ring plate made of Wall ring plate made of Wall ring plate made of composite...
Open the catalog to page 3High pressure fans Size 710 Addendum Fans and Control Technology for agriculture 04/2018 FE2owlet for three phase alternating current, 4-4 pole Characteristic curve Motor technology: AC Rated voltage UN: 3~ 400 V (∆/Y) ±10 %* Rated frequency fN: 50 Hz* Input power P1: 2.60/1.70 kW* Rated current IN: 4.80/2.90 A* Rated speed nN: 1330/1050 min-1* Starting current IA: 20.00 / 6.50 A Current increase ∆I: 5 % Thermal class: THCL155* Min. permitted ambient temperature tR(min): -40 °C Max. permitted ambient temperature tR(max): 60 °C Electrical connection: Terminal box Number of blades: 7 Degree of...
Open the catalog to page 4Addendum Fans and Control Technology for agriculture 04/2018 High pressure fans Size 710 Performance data Type Characteris Connection Voltage Operating Current Input power Speed Acoustic Specific pressure power Fan ordering information Airflow direction A Q (guard grille suction Design T (without guard grille) Q (without guard grille) ^d'e) Wall ring plate Weight kg 26.00 Wall ring plate made of Wall ring plate made of coated sheet steel coated sheet steel Control technology Frequency inverters Fcontrol 3~
Open the catalog to page 5High pressure fans Size 800 Addendum Fans and Control Technology for agriculture 04/2018 FE2owlet for three phase alternating current, 4-4 pole Characteristic curve Motor technology: AC Rated voltage UN: 3~ 400 V (∆/Y) ±10 %* Rated frequency fN: 50 Hz* Input power P1: 3.90/2.60 kW* Rated current IN: 6.80/4.20 A* Rated speed nN: 1310/1050 min-1* Starting current IA: 32.00 / 10.00 A Current increase ∆I: 5 % Thermal class: THCL155* Min. permitted ambient temperature tR(min): -40 °C Max. permitted ambient temperature tR(max): 70 °C Electrical connection: Terminal box Number of blades: 5 Degree of...
Open the catalog to page 6Addendum Fans and Control Technology for agriculture 04/2018 High pressure fans Size 800 Performance data Type Characteris Connection Voltage Operating Current Input power Speed Acoustic Specific pressure power Fan ordering information Airflow direction A Wa|l rin |ate Wall ring plate made of Wall ring plate made of a ring pae coated sheet steel coated sheet steel Weight kg 61.80 65.60 Control technology Frequency inverters Fcontrol 3~
Open the catalog to page 7High pressure fans Size 910 Addendum Fans and Control Technology for agriculture 04/2018 FE2owlet for three phase alternating current, 4-4 pole Characteristic curve Motor technology: AC Rated voltage UN: 3~ 400 V (∆/Y) ±10 %* Rated frequency fN: 5 Hz* Input power P1: 5.20/3.10 kW* Rated current IN: 8.80/5.00 A* Rated speed nN: 1210/900 min-1* Starting current IA: 32.00 / 10.00 A Current increase ∆I: 0 % Thermal class: THCL155* Min. permitted ambient temperature tR(min): -40 °C Max. permitted ambient temperature tR(max): 40 °C Electrical connection: Terminal box Number of blades: 5 Degree of protection...
Open the catalog to page 8Addendum Fans and Control Technology for agriculture 04/2018 High pressure fans Size 910 Acoustic Specific pressure power Performance data Type Characteris Connection Voltage Operating Current Input power Speed Q (guard grille suction Q (guard grille suction Design T (without guard grille) Q (without guard grille) sid'e) Q (without guard grille) side) Article no. 177748 Wall ring plate Weight kg 46.80 Wall ring plate made of Wall ring plate made of Wall ring plate made of Wall ring plate made of composite material composite material coated...
Open the catalog to page 9High pressure fans Size 630 Addendum Fans and Control Technology for agriculture 04/2018 FE2owlet with ZAplus for three phase alternating current, 4-4 pole Characteristic curve Motor technology: AC Rated voltage UN: 3~ 400 V (∆/Y) ±10 %* Rated frequency fN: 50 Hz* (60Hz data available) Input power P1: 1.75/1.35 kW* Rated current IN: 3.70/2.20 A* Rated speed nN: 1400/1210 min-1* Starting current IA: 20.00 / 6.50 A Current increase ∆I: 5 % Thermal class: THCL155* Min. permitted ambient temperature tR(min): -40 °C Max. permitted ambient temperature tR(max): 70 °C Electrical connection: Terminal...
Open the catalog to page 10High pressure fans Size 630 Addendum Fans and Control Technology for agriculture 04/2018 Type Characteris Connection Voltage Operating Current Input power Speed Acoustic Specific pressure power Fan ordering informationAirflow direction Airflow direction Design L (guard grille suction side) Ontop Q (guard grille suction side) L (without guard grille) Ontop L (guard grille pressure oi p Q (without guard grille) Q (guard grille pressure side) ZAplus attachable on both sides. Control technology Frequency inverters Fcontrol 3~ Design L - ZAplus Ontop, guard grille pressure sideDesign...
Open the catalog to page 11260 Pages
334 Pages
544 Pages
4 Pages
14 Pages
4 Pages
12 Pages
4 Pages
8 Pages
10 Pages
4 Pages
144 Pages
112 Pages
5 Pages
4 Pages
20 Pages
24 Pages
11 Pages
38 Pages
38 Pages
24 Pages
30 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page