VRCM12-2 RCMU

VRCM12-2 RCMU

VRCM12-2 RCMU

Product catalog summary
General Introduction:
The document describes the VRCM12-2 Residual Current Monitoring Unit (RCMU) designed for electric vehicle (EV) chargers. It detects type B residual current using the flux-gate principle, ensuring high monitoring precision and low temperature drift. All components comply with the AEC-Q automotive class standard, and the unit meets the IEC62752(E)-1:2016 standard for residual current detection.
Application:
The RCMU is suitable for use in electric vehicle chargers, including IC-CPD, wallboxes, solar inverters, and UPS systems. It offers isolated measurement and panel mounting capabilities.
Main Features:
  • Resolution ratio of 0.2mA
  • Outputs a signal when DC 6mA or AC 30mA residual current occurs
  • Low temperature drift and high monitoring precision
  • Compliant with multiple standards including IEC 62955 and GBT 18487.1-2015
Product Advantages:
  • High precision monitoring
  • Low temperature drift
  • Use of auto class components
Reference Standards:
  • IEC62752(E)-1:2016
  • IEC 62955
  • NB/T 42077-2016
  • GBT 18487.1-2015
  • 2002/95/EC
Limit Parameters:
Attention is required to adhere to parameter limits to avoid device damage. Key electrical parameters include a supply voltage (VCC) of 5V, a maximum supply voltage (VDS) of 40V, and a maximum supply current (IC) of 50mA.
Electrical Parameters:
  • Supply voltage: 4.75V to 5.25V
  • Consumption current: 30mA
  • Zero temperature drift: 2mA
  • PWM frequency: 7.8 to 8.2 kHz
  • DC tripping current: 4 to 5.6mA
  • AC tripping current: 20 to 28mA
Tripping Time:
The document provides detailed tripping times for various current levels and frequencies, ensuring quick response to residual currents.
Power On Sequence and Pin Definition:
The document outlines the power-on sequence and provides a detailed pin definition for the RCMU, including test input, power supply, and output signals.
See more

Catalog excerpts

VRCM12-2 RCMU-1

Zhejiang VEKON Technology Co.,Ltd. PROFESSIONAL CIRCUIT BREAKER MANUFACTURER a vi VRCM12-2 RCMU Residual current monitoring unit for EV charger General introdution VRCM12-2 RCMU detects type B residual current, which adopts flux-gate principle, with features of high monitoring precise and low temperature drift. All components inside conform to AEC-Q auto class standard. Its output Trip signal and PWM have the function of monitoring current. Function of residual current detection meet the standard: IEC62752(E)-1:2016. Application: Residual current monitoring for electric vehicle of IC-CPD, wallbox and charger, solar inverter, UPS, etc. Main features Isolated measurement Panel mounted Resolution ratio 0.2mA DC 6mA residual current occurs, signal will be output i AC 30mA residual current occurs, signal will be output Typical application Charger-Model 3 Charger-Model 4 IC-CPD Other residual current monitoring Product advantages Low temperature drift Auto class components inside High monitoring precise flux-gate principle

 Open the catalog to page 1
VRCM12-2 RCMU-2

Attention should be paid to parameter limits, otherwise the device may be damaged.

 Open the catalog to page 2
VRCM12-2 RCMU-3

Zhejiang VEKON Technology Co.,Ltd. PROFESSIONAL CIRCUIT BREAKER MANUFACTURER

 Open the catalog to page 3
VRCM12-2 RCMU-4

InternalCheck Current X6 X30 ERROR Remarks:after testing signal,zero data will be input to Flash

 Open the catalog to page 4

All ZHEJIANG VEKON TECHNOLOGY CO.,LTD catalogs and technical brochures

  1. VRCM16

    5  Pages

  2. VL26-63 RCCB

    2  Pages

  3. VL17-63 RCCB

    2  Pages

  4. VL13-63 RCCB

    2  Pages

  5. VL11-63 RCCB

    2  Pages

  6. VL20-100 RCCB

    2  Pages

  7. VL15-63 RCCB

    2  Pages

  8. VL12-63 RCCB

    2  Pages

  9. VL10-63 RCCB

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.