Pomanique Vacuum Recloser ZX38 series
9Pages

{{requestButtons}}

Catalog excerpts

Pomanique Vacuum Recloser ZX38 series - 2

Introduction & Benefits Pomanique’s ZX-Series three-phase, electronically controlled, vacuuminterrupting distribution automation switch provides reliable, economical switching, sectionalizing, advanced metering, and automation systems for distribution circuits rated up to 38 kV. Controlled Arc Fault Venting ability - Adoptvacuuminterrupters,thereclosercanquenchtheAcrfault Withinveryshorttime. TheAFVrecognizesless-than-criticalinstantaneousovercurrent,so duringthedesignofRecloser,thearcfaultcontainmentandventing hasbeenamandtoryrequirement. The ZX switch combines solid cycloaliphatic- epoxy...

Open the catalog to page 2
Pomanique Vacuum Recloser ZX38 series - 3

Switch unit description Recloser principle Reclosersareusedinoverheadlinesandinsubstations.Likecircuit-breakers theyarecapableofswitchingnormalandfaultcurrents.Theyareequipped withsensorsandcontrollerbeingtheprotectionandcontroldevice.Incase of a temporary line fault, they can trip and reclose up to four times, thus avoidinglongernetworkinterruptions. Recloser cycle Incaseofanetworkfault,therecloseropensandreclosesseveraltimes.In case of temporary faults, the automatic reclosing significantly reduces the outage times. While the trip settings for each operation can be set individually....

Open the catalog to page 3
Pomanique Vacuum Recloser ZX38 series - 4

Controller description TheMicroprocessorBasedcontroller FTU-R200provideprotection,control, instrumentation and metering with integrated input and output logic, data logging&faultreports. Communication access to controller functionality is via electrical RS485 port for remote connection. Additional rear port options including RS232 port is available. Thecontrollerismountedinthecontrolcubicle.Alongwiththecontroller,this cubicle also contains the auxiliary power supply with batteries for uninterruptiblepowersupply,electronicboardsandcircuitbreakers. The controller contains a large number of...

Open the catalog to page 4
Pomanique Vacuum Recloser ZX38 series - 5

General Protection Features Operating sequence Sensitive Earth Fault (SEF) PickupI0:0.1~20A(step:0.1A) Reclose times are selectable. The operating sequence is V0:10~80%(step:1%) definedby: OperatingAngle:0~345°(1°step) O-1strt-CO-2ndrt-CO-3rdrt–CO OpeartingTime:0.1~30sec(step:0.1sec) _Reclos Under/ Over Voltage Protection VoltageUnerLevel:50~90% Negative Sequence Overcurrent(Broken conductor) PickupI2/I1level:30.0~100.0(step:1%) I2/I1delaytime:0.01~100.0(step:0.01sec) High Current Trip (HCT) Phase-HCTPickupLeve:10~2000A(step:0.1A) Phase-HCTAdder:0.01~1(step:0.01sec)...

Open the catalog to page 5
Pomanique Vacuum Recloser ZX38 series - 6

General Protection Features Commmunication Interface Recording Events On FRTU left-side (inside the inner door) Fault Waveform Load Profiling Baud Rate Local / Remote : Control Position (only locally changeable) Open/Close : Switch Body Status Change Command DO (Direct Operate) and SBO (Select Before Operate) On FRTU Front Panel Reset : Annunciator Manual Reset Command Battery Test : Battery & Charger Circuit Check Protection Function Blocking User Configurable DO Points (reserved) : 2 ProtocolMonitor(CommunicationFrameCheck) Real-timeDisplay:MeasurementandStatusData...

Open the catalog to page 6
Pomanique Vacuum Recloser ZX38 series - 7

Technical characteristics Pomanique Value Manufacturing standard Nominal operating voltage Voltage Range Breaking Capacity Continuous rated current capacity Cable charging current Line charging current Short-term nominal allowable current capacity. Lightning impulse withstand voltage. Power frequency withstand voltage (1 min dry) Secuencia de Operación Nominal Minimum amount of operation Number of Voltage Sensors Current Transformer Number / Ratio Mechanism Type Magnetic Actuator Minimum external creepage distance Enclosure Material Relay protection functions Protection Current Range...

Open the catalog to page 7
Pomanique Vacuum Recloser ZX38 series - 8

Rated short-duration P.F. withstand voltage Max. interrupting time / max. closing time Cable charging current Line charging current Rated lightning impulse withstand voltage Minimum clearance, phase-toearth Rated short-circuit making current Clearance, phase-to-phase Rated short-circuit breaking current Creepage distance, phase-toearth Rated duration of short-circuit Impedance μΩ between connections Rated continuous current Technical data

Open the catalog to page 8
Pomanique Vacuum Recloser ZX38 series - 9

Pole mount Substation mount F.14, Building 3, Headquarter Economic Park, No. 6688 Xuyang Rd., Yueqing, Zhejiang, China Email:info@pomanique.com www.pomanique.com

Open the catalog to page 9