Remote Flange DPTransmitter RANGE/ URL/LRL LFT720 Remote Flange Transmitter is composed of the LFT710 Differential Pressure Transmitter and a small welded remote flange with a capillary tube. Between the flange and the sensor, silicon oil and other filling fluids are used to transmit pressure, to prevent the measured medium from passing through the impulse pipe. Which will impact the measurement. The impact of the measured medium pass through the impulse pipe includes crystallization, solidification vaporization (boiling), condensation fractionation (severe change) and etc. The Transmitter is used to measure the liquid level, flow and pressure of liquid, gas or steam, and then convert it into 4-20 mA signal output. The working principle of LFT720 Flange Transmitter is the same as LFT710 Differential Pressure Transmitter except that the pressure transmission path on the positive pressure side is slightly different, that is the pressure acting on the high-pressure side firstly passes through the diaphragm and the filing liquid of the remote flange, and then pass to the transmitter body via capillary tube, and finally reach the high pressure side of measurement sensor. Zero point and span can be adjusted to any value within the measuring range in the Table, as long as the calibration range a minimum span. It can install at any position through the liquid-level flange. The best state is to keep the process flange in a vertical state. The offset caused by the position deviation can be corrected by clearing the operation. •Alarm current standard setting: high alarm mode. • Non-alarm mode (maintain): maintain the current practical value before the fault. • The total damping constant time equal to the sum of the damping time constant of the electronic circuit components and the sensing bellows. •Electronic circuit component damping time: 0-60S range adjustable. •Sensing bellows damping time:^0.2S. •Power-on start-up time after power failure: £5S. •Data recovery to normal usage time: £2S. 8)Environment Temperature The range is adjusted based on the standard zero point. The diaphragm is stainless steel 316L, and the filling liquid is silicone oil. Includes linearity, hysteresis and repeatability from zero. TEST PROJECT When the power supply voltage changes within 12-36V DC, the change of zero point and range does not exceed ±0.005% of the upper limit of the range/V, which can be ignored. Range can be adjusted by turn down adjustment within URL and LRL. Such as for URL/LRL -40-40 kPa, TD=10, range can be 0~4kPa or -4~4kPa. Turn down should be as low as possible to ensure accuracy. In general, turn down is within 10, too big will affect accuracy. INSTALLATIONl)Power Supply and Load Conditions ITEM
Open the catalog to page 1PHYSICAL SPECIFICATIONS PROCESS CONNECTION DESCRIPTION Measuring bellows l)Dimension(mm) • M20»1.5 stainless steel T-shaped joint (code 2)
Open the catalog to page 2LEFOODIAPHRAGM SEAL SELECTION GUIDE
Open the catalog to page 3MODEL AND SPECIFICATION CODE LIST 1. Differential pressure monoflange remote transmission (selection)
Open the catalog to page 42. Differential pressure double flange (option) Model and specification code list
Open the catalog to page 52 Pages
2 Pages
3 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
鄂公网安备42018502009509号 -