2)Range and upper&lower limits LEFOO LFT720 Flange-mounted Transmitter is composed of LFT710 Differential Pressure Transmitter and a welded liquid level flange Between the flange and the sensor, silicon oil and other filling fluids are used to transmit pressure, to prevent the measured medium from passing through the impulse pipe then impact the measurement. The impact of the measured medium pass through the impulse pipe includes: crystallization, solidification, vaporization (boiling), condensation, fractionation (severe change) and etc. The Transmitter is used to measure the liquid level, flow and pressure of liquid, gas or steam, and then convert it into 4~20mA signal output. The working principle of the LFT720 Flange-mounted Transmitter is the same as LFT710 Differential Pressure Transmitter except that the pressure transmission path on the positive pressure side is slightly different, that is the pressure acting on the high-pressure side first passes through the diaphragm of the liquid level flange and the filling liquid, and then pass through the transmitter body, and finally reach the high pressure side of the measuring sensor. SPECIFICATION 1)Reference accuracy of range adjustment The range is adjusted based on the standard zero point. The diaphragm is stainless steel 316L, and the filling liquid is silicone oil. RANGE/ URL/LRL 3)Zero Setting Zero point and range can be adjusted to any value within the measuring range in the table, as long as: calibration range Z minimum range 4)lnstallation position influence It can be installed at any position through the liquid level flange. The best state is to keep the process flange in a vertical state. The offset caused by the position deviation can be corrected by clearing the operation. 6) Alarm Current • Low alarm model (Min):3.8mA. • Alarm current standard setting: high alarm mode. • Non-alarm mode (maintain): maintain the current practical value before the fault. • The total damping constant time equal to the sum of the damping time constant of the electronic circuit components and the sensing bellows. • Electronic circuit component damping time: 0-60S range adjustable. ■Sensing bellows damping time:<0.2S. • Power-on start-up time after power failure: <5S. ■Data recovery to normal usage time: S2S. 2)Power Impact When the power supply voltage changes within 12 - 36V DC, the change of zero point and range does not exceed ±0.005% of the upper limit of the range/V, which can be ignored. Within the range of the upper and lower limits, the TD value can be adjusted within the allowable range to select the range. For example, the upper and lower limits are -40~40kpa. At this time, choose to adjust the TD value to 10, and choose to output 0~4Kpa, or -4~4kpa. In order to ensure the accuracy, the TD value should be as small as possible, generally within 10, too large will affect the accuracy. INSTALLATIONl)Power Supply and Load Conditions ITEM
Open the catalog to page 1LEFOO TYPE ELECTRICAL CONNECTION PROCESS CONNECTION DESCRIPTION
Open the catalog to page 2LEFOOMODEL AND SPECIFICATION CODE LIST l.Differential pressure single flange (selection)
Open the catalog to page 42. Differential pressure double flange (option)
Open the catalog to page 52 Pages
2 Pages
3 Pages
3 Pages
1 Page
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
鄂公网安备42018502009509号 -