Catalog excerpts
The product data referred to in the company shall be subject to material object. Subject to change without notice. The company has the final right to interpret. This album is printed with eco paper. Cherish resources, treat the environment. INDUSTRIAL CONTROL PRODUCT Everything for electrical safety ADDWenzhou Brige Industrial Zone,Beibaixiang Town,Yueqing,Zhejiang,China 325603 Tel0086-577-62771036 Tel0086-13567770207 E-mailsale@cngeya.com Webwww.geya.com GEYAElectrical Safet
Open the catalog to page 1Founded in 2007,Geya Electrical Co. Ltd was located in Wenzhou, Zhejiang, China. Our company integrates R&D, production and sales, and committed to be the technology enterprise of lowvoltageelectricalequipmentandautomationcontrolproducts. Afteryearsofoperating,ourannualturnoverhasexceeded100millionyuan.Geya’ sproductseries involve a variety of low-voltage electrical equipment and automation control products, including miniaturecircuitbreaker(MCB),moldedcasecircuitbreaker(MCCB),residualcircuitbreaker(RCB), isolation switch, contactors, relays, timer, distribution box, etc. The product series...
Open the catalog to page 2PURSUENATUREOFTHINGS REACHTOTHEWORLD Zhejianggeyaelectricalco.,ltd RELAY
Open the catalog to page 3Single-function time relay TimeRelay Functions Diagram Applications -Suitable for applications where function and time requirements are know. -Time switch , possible to be used for pump decay time after switching heating off , switching of fans. -Single-function relay with possibility of time setting by a potentiometer. -Choice of 2 functions: A:Delay ON B:Delay OFF -Time scale 0.1 s - 10 days divided into 10 ranges. - Relay status is indicated by LED. - 1-MODULE,DIN rail mounting. At-Delay ON+Instantaneous contact Bt-Delay OFF+Instantaneous contact A Rated control supply voltage...
Open the catalog to page 4Multifunction time relay Functions Diagram -Multifunction time relay can be used for electrical appliances, control of lights, heating, motors, pumps and fans (10 functions, 10 time ranges, multi-voltage). Feature -10 functions: - 5 time functions controlled by supply voltage - 4 time functions controlled by control input - 1 function of latching relay -Comfortable and well-arranged function and time-range setting by rotary switches. -Time scale 0.1 s - 10 days divided into 10 ranges. - Relay status is indicated by LED. - 1-MODULE,DIN rail mounting. F:Single Shot When the input voltage U is...
Open the catalog to page 5Extended multifunction time relay Functions Diagram -Multifunction time relay can be used for electrical appliances, control of lights, heating, motors, pumps and fans (10 functions, 10 time ranges, multi-voltage). When relay Un is powered on, the relay starts to delay, and the output contact is closed after delay t. After the relay Un is de energized, the output contact R is disconnected and the S control signal is invalid in this function mode. Bw:Offdelay(S trigger time accumulation) -10 functions: - 8 time functions controlled by supply voltage - 2 time functions controlled by control...
Open the catalog to page 6Dual function time relay Functions Diagram -Dual function time relay can be used for industrial equipment, lighting control, heating element control, motor and fan control, with two delay modes, and the delay range covers 0.1 seconds to 10days. When the relay Un is powered on, the relay starts to delay, and the output contact closes afterdelay.When Un is powered off, the output contact is disconnected. When the relay Un is powered on, the output contact of the relay will close immediately and start to delay, and output after delay,The contact is open. If the delay time t is not up to the...
Open the catalog to page 7Digital Setting Time Relay Functions Diagram -Multifunctional time relay with digital settings can be used for industrial equipment, lighting control, heating element control, motor and fan control. It has four delay modes and the delay range covers 0.1 seconds to 99 hours. E:Off Delay (S Break) When the input voltage U is applied, timing delay t begins. Relay contacts R change state after time delay is complete. Contacts R return to their shelf state when input voltage U is removed. Trigger switch is not used in this function. Input voltage U must be applied continuously. When trigger...
Open the catalog to page 8Digital display time relay Functions Diagram -Multifunctional time relay can be used for industrial equipment, lighting control, heating element control, motor, fan control. -With 20 delay modes, the delay range covers 0.1 seconds to 99 days. On delay with external contorl Feature -20 delay modes: -5 delay modes controlled by power supply -13 delay modes controlled by signal -ON, OFF mode -Ultra wide delay range, 0.1 seconds - 99 days can be set. - Relay status is indicated by LED. - 1-MODULE,DIN rail mounting. Latching relay Off delay with external start Repeat cycle with external contorl...
Open the catalog to page 9Double delay time relay Wiring Diagram Applications -For gradual switching of heavy powers (e.g. el.heating), prevents current strokes in the main. Feature -2x Delay ON (2 time relays in one) -Time scale 0.1s - 10 days divided into 10 time ranges: 0.1s - 1s / 1s - 10s / 0.1min - 1min / 1min - 10min / 0.1h - 1h / 1h - 10hrs / 0.1 day - 1 day / 1 day - 10 days / ON / OFF. -Times t1 and t2 are independantly adjustable. - t1 and t2 are switched on after supply voltage connection. - Relay status is indicated by LED. - 1-MODULE,DIN rail mounting. Functions Diagram 2T Rated control supply voltage:...
Open the catalog to page 10Asymmetric cycler time relay Wiring Diagram -It is used for regular room ventilation, cyclic dehumidification, light control, circulating pumps, noon signs, etc. Feature -2 time functions: -Cycler beginning with pulse -Cycler beginning with pause -Function choice is done by an external jumper of terminals S-A1. -Time scale 0.1 s - 100 days devided into 10 time ranges: (0.1 s - 1 s / 1 s - 10 s / 0.1 min - 1 min / 1 min - 10 min / 0.1 hrs - 1 h / 1 hrs - 10 hrs / 0.1 day - 1 day /1 day - 10 days /3 days - 30 days / 10 days - 100 days). -Relay status is indicated by LED. -1-MODULE,DIN rail...
Open the catalog to page 11Pulse output time relay Wiring Diagram -It is used to delay and generate a pulse, which is used to delay the connection of a load for a period of time. Feature -Separate delay time and pulse width setting can set different delay time. -Time scale 0.1 s - 100 days. -The delay time can be reset by shorting S-A1. - With AC/DC 12V-240V ultra wide operating voltage specifications are optional. -Relay status is indicated by LED. -1-MODULE,DIN rail mounting. Functions Diagram Model and connotation GRT8 P Rated control supply voltage Numberofcontacts 2:2×SPDT Pulse output time relay GRT8 Series...
Open the catalog to page 12All Zhejiang Geya Electrical Co. catalogs and technical brochures
-
Relay Module
5 Pages
-
Solar Product Catalog
50 Pages
-
MINIATURE CIRCUIT BREAKER