The D20 series explosion-proof solenoid valve is a newly designed product by Zhejiang Datian Machine Co., Ltd. It is constructed from brass forging and offers several key features: a novel structure with an appealing appearance, zero leakage, high and small flow accuracy for oil delivery, multiple voltage options (AC220V/50Hz, AC230V/60Hz, AC110V/50Hz, AC115V/60Hz, DC24V), and explosion-proof capabilities suitable for computer fuel dispensers.
2. Certification
The solenoid valve meets several standards for explosion-proof performance, including GB3836.1-2010 and GB3836.2-2010, and holds an explosion-proof mark of Ex d IIB T4 Gb. It is certified for use in Zones 1 and 2 with explosive gas mixtures of IIA and IIB class T1~T4 groups. The product has passed inspection by the National explosion-proof Electrical Product Quality Supervision and Inspection Center, with certificate number CNEx15.4019, and has obtained the China national compulsory product CCC certification, certificate number 2020312307000140.
3. Model and Explosion-proof Mark Description
Details on product model meaning and explosion-proof mark are provided but not specified in the summary.
4. Technical Parameters
The solenoid valves are available in models D20, D25, and D40, suitable for mediums like gasoline, diesel, and kerosene. They have diameters of 20mm, 25mm, and 40mm, respectively, with high flow rates of ≥50, ≥100, and ≥250, and low flow rates ranging from 2.5-6.5. The rated voltage options are AC220V/50Hz, AC230V/60Hz, AC110V/50Hz, AC115V/60Hz, and DC24V, with a rated power of 2 x 7W. The nominal pressure is 0.35Mpa, and the ambient temperature range is -35℃ to +55℃.
5. Working Principle
The valve operates as a pilot-operated solenoid valve with two movable iron cores. Energizing the upper coil lifts the upper iron core to open a small flow channel. Energizing both coils opens a large flow channel. De-energizing the lower coil closes the pilot hole, maintaining the small flow channel open until the upper coil is de-energized. It is crucial not to energize the lower coil without the upper coil being energized.
6. Installation and Maintenance
The solenoid valve should be installed horizontally, with the medium flow direction matching the arrow on the valve body. The power supply voltage and medium pressure must align with the nameplate. A permanent four-core cable is used for connection, and the cable's free end should be connected to an explosion-proof box. Regular maintenance includes ensuring the cover is not opened when powered, switching the valve on and off monthly if unused, and replacing aged sealing rings with company-provided parts.
7. Order Notice
When ordering, specify the product model and name, rated voltage, frequency of power supply, connection mode, and any special requirements.
See more

Catalog excerpts

Solenoid Valve D20/D25/D40/D20U-1

Instructions Solenoid Valve Model: D20 D25 D45 1. Features D20 series explosion-proof solenoid valve (hereinafter referred to as solenoid valve) is the latest product designed by our company. The solenoid valve body is made of brass forging and has the following characteristics and uses. a. Novel structure and beautiful appearance. b. Zero leakage. c. High flow and small flow to make sure the high accuracy of oil delivery. d. Rated voltage: AC220V/50Hz, AC230V/60Hz, AC110V/50Hz, AC115V/60Hz, DC24V for your choice. · e. Explosion-proof performance, used for computer fuel dispensers. 2. Certification The explosion-proof performance of the solenoid valve conforms to GB3836.1-2010 "Electrical Equipment for Explosive gas environment Part 1: General requirements", GB3836.2-2010 "Electrical equipment for Explosive gas environment Part 2; flameproof type" d ", CNCA-C23-01: 2019 "Implementation Rules for Mandatory Product Certification" and CNEX-C2301-2019 "Detailed Rules for the Certification of Strong Manufactured Products" are made into flast-proof type, and its explosion-proof mark is Ex d IIB T4 Gb. It is suitable for places in Zone 1 and Zone 2 containing explosive gas mixtures of IIA and IIB class T1~T4 groups. The product has passed the inspection of the National explosion-proof Electrical Product Quality supervision and Inspection Center, which has been issued explosion-proof certificate, certificate number is: CNEx15.4019 The product has obtained China national compulsory product CCC certification, certificate number is: 2020312307000140

 Open the catalog to page 1
Solenoid Valve D20/D25/D40/D20U-2

ATEX Certification

 Open the catalog to page 2
Solenoid Valve D20/D25/D40/D20U-3

3. Model and explosion-proof mark Description: 3.1 Product model meaning 3.2 Meaning of explosion-proof mark: 4. Technical parameters Model Gasoline, diesel, kerosene High Flowrate Rated voltage Rated power Nominal pressure Ambient temperature

 Open the catalog to page 3
Solenoid Valve D20/D25/D40/D20U-4

5. Working principle 5.1 working principle This valve is a pilot-operated solenoid valve. which has two movable iron cores, and there are rubber pads at the lower ends of the iron cores. When the upper coil is energized, the upper iron core is sucked up and a small flow channel is opened. When the power is lost, the upper iron core is pressed down by the spring force to close the valve. When the upper coil is energized first to lift the upper iron core, and then the lower coil is energized (or the upper and lower coils are energized at the same time), the lower iron core is lifted up to open...

 Open the catalog to page 4
Solenoid Valve D20/D25/D40/D20U-5

6. Installation and Maintenance 6.1 The medium flow direction in the solenoid valve should be consistent with the direction of the arrow on the valve body, and the power supply voltage and medium pressure should be consistent with those marked on the nameplate. 6.2 The solenoid valve should be connected horizontally and installed on the horizontal pipeline. 6.3 The introduction device of the solenoid valve adopts a permanent four-core cable. The free end of the cable should be properly processed and connected to the corresponding explosion-proof box. The minimum outer diameter of the applicable...

 Open the catalog to page 5