Founded in 1997, BSB is a national high-tech enterprise for devetoping, manufacturing hydraulic magnetic circuit breaker, DC Contactor and relays. BSB established a complete research and development system and has our own "provincial research and development center”. Gathered a large number of electronics, machinery and hydraulic, electromagnetic science and technology talents, has won a number of national patents, and owns dozens of independent intellectual property rights. BSB products authenticated by CE, VDE, TUV, CSA, UL, CCC and ROHS. Our products are widely used in new energy...
Open the catalog to page 2
OUffl UL esUilEM o^acccsmaE o «ai rohs jf;e*ia C*C
Open the catalog to page 3
bsd mmi Characteristic Ordering IMi"0 2S6CT-3C-1; U jr.VX •Strong control load capacity: rated operational voltage12VDC~1000VDC, rated operational current 30A •Safe: Fully sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment •Reliable: Adopt DC high voltage non - polarity design, the breaking capacity is higher and more reliable, convenient and reliable installation/wiring •ROHS: All components meet the latest EU RoHS environmental requirements Contact...
Open the catalog to page 5
Characteristic •Strong control load capacity: rated operational voltage12VDC~1000VDC, rated operational current 50A •Safe: Fully sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment •Reliable: Adopt DC high voltage non - polarity design, the breaking capacity is higher and more reliable,convenient and reliable installation/wiring •ROHS: All components meet the latest EU RoHS environmental requirements Contact parameter Coil parameter 51 Rated...
Open the catalog to page 6
Ordering Company abbreviation Rated current Rated operational voltage Unit: mm Rated control supply voltage (Customized code when customer has special requirements) Note: Except for special notes, the ambient temperature of electrical durability test is 23°C, and the on-breakratiois: Is: 9s; Note: outgoing line length: 300mm±20mm; product without tolerance, when<10mm, tolerance ±0.3mm; when dimension between (10-50) mm, tolerance ±0.5mm; when dimension>50mm, tolerance ±0.8mm.
Open the catalog to page 7
DSD Characteristic •Strong control load capacity: rated operational voltage12VDC~1000VDC, rated operational current 100A •Safe: Fully sealed with epoxy resin, contact and coll will not be oxidized, product performance Is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment • Reliable: Adopt DC high voltage non - polarity design, the breaking capacity is higher and more reliable, convenient and reliable installation/wiring • ROHS: All components meet the latest EU RoHS environmental requirements Contact parameter Coil parameter Ordering...
Open the catalog to page 8
Notes: outgoing line length; 300mm±20mm; product without tolerance, whenSIOmm, tolerance ±0.3mm; when dimension between (10-50) mm, tolerance ±0.5mm; when dimension 550mm, tolerance ±0.8mm. •Strong control load capacity: rated operational voltage12VDC~1000VDC, rated operational current 100A •Safe: Fully sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment •Reliable: Adopt DC high voltage non - polarity design, the breaking capacity is higher and more...
Open the catalog to page 9
P/N BSBC7-100-P Ordering /XXX Unit: mm Coil type (Customized code when customer has special requirements) —:450V :250V Note: Except for special notes, the ambient temperature of electrical durability test is 23C, and the on-bneakratiois: Is: 9s; Notes: outgoing line length; 300mm±20mm; product without tolerance, when<10mm, tolerance ±0.3mm; when dimension between (10-50) mm, tolerance ±0.5mm; when dimension 250mm, tolerance ±0.8mm.
Open the catalog to page 10
Characteristic •Strong control load capacity: rated operational voltage12VDC~1000VDC, rated operational current 150A •Safe; Fully sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment • Reliable: Adopt DC high voltage non - polarity design, the breaking capacity is higher and more reliable, convenient and reliable installation/wiring • Energy conservation: Using PWM control technology, effectively control the coil power and action characteristics, more...
Open the catalog to page 11
Vertical mounting: BSBC7-150 outline dimension Notes: outgoing line length; 300mm±20mm; product without tolerance, when<10mm, tolerance ±0.3mm; when dimension between (10-50) mm, tolerance ±0.5mm; when dimension >50mm, tolerance ±0.8mm. • Strong control load capacity: rated operational voltagel 2VDC-1000VDC, rated operational current 200A • Safe: Fully sealed with epoxy resin, contact and coil will not be oxidized, product performance is not affected by external environment, no arc outbursts, can be worked in explosive and harmful environment • Reliable: Adopt DC high voltage non - polarity...
Open the catalog to page 12
bsd mmi Ordering Coil typeD Unit: mm Mounting type ( Nil: Vertical mounting; W: Horizontal mounting) (Customized code when customer has special requirements) Note: Except for special notes, the ambient temperature of electrical durability test is 23‘C, and the on-breakratiois: Is: 9s; Notes: outgoing line length; 300mm±20mm; product without tolerance, whenSlOmm, tolerance ±0.3mm; when dimension between (10-50) mm, tolerance ±0.5mm; when dimension >50mm, tolerance ±0.8mm.
Open the catalog to page 13All ZHEJIANG BSB ELECTRICAL APPLIANCES CO. catalogs and technical brochures
-
KC Certificate
1 Pages
-
TUV Certificate
1 Pages
-
CSA Certificate
2 Pages
-
UL certificate
1 Pages
-
BSB/CIRCUIT BREAKER/BC5
2 Pages
-
BSB/CIRCUIT BREAKER/B3
14 Pages
-
BSB/CIRCUIT BREAKER/B2
15 Pages
-
BSB/CIRCUIT BREAKER/B1
11 Pages