BSB/CIRCUIT BREAKER/B3

BSB/CIRCUIT BREAKER/B3
1 / 14 PagesView full catalog

BSB/CIRCUIT BREAKER/B3

Product catalog summary
Product Overview
The B3 Series Hydraulic Electromagnetic Circuit Breaker is designed for AC50Hz/60Hz networks with a rated voltage of DC80V or AC480V. It offers reliable protection against short circuits and overloads for various equipment and lines.
Specifications
  • Maximum Voltage: 480/277VAC, 50/60 Hz, 80VDC
  • Current Ratings: 1A to 100A
  • Auxiliary Switch: SPDT, 5A 250VAC, 1.0A 80VDC
  • Insulation Resistance: Minimum of 100 Megohms at 500VDC
  • Dielectric Strength: 1500V, 50/60Hz for one minute between all terminals
  • Endurance: 10,000 ON-OFF operations at 6 per minute with rated current and voltage
  • Operating Temperature: -40℃ to +85℃
  • Installation Torque: 0.8-1.0NM for panel mounting screws, 1.7-2.3NM for terminal connections
  • Number of Poles: 1, 2, or 3 poles
  • Weight: Approximately 110 grams per pole
  • Certifications: IEC/EN 60934, UL1077, GB17701, UL489A, UL489
Electrical Characteristics
The circuit breaker supports various configurations with different voltage ratings, phases, and short circuit capacities, suitable for both AC and DC applications with specific tripping delay types.
Time Current Operating Characteristics
Detailed tripping characteristics are provided for different delay types (D0, D1, D2, D3, A0, A1, A2, A3) for currents up to and exceeding 100A.
Specification and Code Implication
Specification codes are outlined for selecting the appropriate circuit breaker model, including type, operating device, rated current, voltage, number of poles, terminal type, auxiliary switch, circuit type, delay type, handle and rocker color combination, installation manner, and authentication code.
Form & Fit Drawings
Detailed drawings for handle, rocker, and terminal dimensions are included, along with installation guidelines for auxiliary switches, providing precise measurements and instructions for various configurations.
Rocker Types
The circuit breaker features various rocker types, including vertical and horizontal configurations, available in single or dual colors, with options for indicating "ON" or "OFF" states. Some rockers include a guard for additional protection.
Circuit Diagrams
  • Parallel Connection (101A-250A): Includes auxiliary components and shows the arrangement of contacts and current inductive coils.
  • Circuit Diagram (1A-100A): Details the contacts and current inductive coil setup without auxiliary components.
See more

Catalog excerpts

BSB/CIRCUIT BREAKER/B3-1

Product Datasheet Product Name:Circuit Break for Equipment Models: Date:20150611

 Open the catalog to page 1
BSB/CIRCUIT BREAKER/B3-2

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker 1 The Scope of Application B3 series product is a hydraulic electromagnetic circuit breaker which our company design and develop by adopting international advanced technology.The circuit breaker consists of shell,operating mechanism,contact arc extinguishing system and hydraulic solenoid tripping device and other parts.The circuit breaker is used inAC50Hz/60Hz,rated voltage DC80V or AC480V equipment network circuit.It is mainly used for a variety of equipment and lines to provide accurate...

 Open the catalog to page 2
BSB/CIRCUIT BREAKER/B3-3

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker Electrical: see table below. Short Circuit Capacity(Amps) Voltage Note: (1) Use back‐up protectors of no more than 125A Voltage Type Minimum Phases Short Circuit Capacity(Amps) UL489

 Open the catalog to page 3
BSB/CIRCUIT BREAKER/B3-4

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name Version B3 Series Hydraulic Electromagnetic Circuit Breaker A Time Current Operating Characteristics (tripping characteristics): Unit: second The following 100A (including 100A) Delay More than 100A Delay Type 3 Specification and code implication(for selection) No. 1 Operating device (please see the style description of rocker switch) R1:Single Color, Flat,Vertical; R2: Single Color, Angle,Vertical; R3:Two Color, Indicate ON, Angle,Vertical; E1: Two Color, Indicate ON, Angle,Horizontal; R4: Two Color, Indicate OFF, Angle,Vertical; E2: Two...

 Open the catalog to page 4
BSB/CIRCUIT BREAKER/B3-5

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name Version B3 Series Hydraulic Electromagnetic Circuit Breaker A Rated Voltage Number of poles Terminal type (Refer to Remark 1) 8(Refer to Auxiliary Remark 4) switch Circuit type (Refer to Remark 2) A:Switch Only(no coil); B:Series Trip(Current); C:Series Trip(Voltage); D:Shunt Trip Voltage Coil 。 Delay Type A0: 50/60Hz Instantaneous; A1: 50/60Hz Short; A2: 50/60Hz Medium; A3: 50/60Hz Long; D0: DC Instantaneous; D1: DC Short; D2:DC Medium; D3:DC Long; H1: DC Short, Hi‐Inrush; H2: DC Medium, Hi‐Inrush; H3: DC Long ,Hi‐Inrush; G1:50/60Hz Short,...

 Open the catalog to page 5
BSB/CIRCUIT BREAKER/B3-6

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker Authenticati on code (Refer to Remark 5) Remarks: 1. The screw connection terminal blocks 2, 3, 4, 5 and Q are recommended for the circuit breakers with rated current higher than 30A, and the solder shall be used; 2. Circuit A: pure switch, the rated current is 30A or 100A; if it is circuit B, the code can be omitted, being unnecessary to be marked. 3. The label of VDE and TUV shall be marked with I‐O, and the UL mark shall be have ON‐OFF; 4. If the code 0 is used, the positions 7 and...

 Open the catalog to page 6
BSB/CIRCUIT BREAKER/B3-7

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker Tripping time(S) Tripping time(S) Rated Current Percentage Rated Current Percentage Tripping time(S) Tripping time(S) Rated Current Percentage

 Open the catalog to page 7
BSB/CIRCUIT BREAKER/B3-8

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker 5 B3 Circuit Breaker Form & Fit Drawings 10.31 5.1 Handle - Form & Fit Drawings 63.87 47.22 Notes: 1.Mounting Style:Threaded inserts,2 per pole 2.Panel Cutout Detail(Tolerance:±0.12mm) 3.All dimensions in millimeters; 4.Tolerance ±0.5 unless otherwise specified.

 Open the catalog to page 8
BSB/CIRCUIT BREAKER/B3-9

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker 5.2 Angel Rocker - Form & Fit Drawings Indicating Color Rocker Guard (Optional) 12.85 Position "ON" Position "OFF" Dual Color 1 Pole Dual Color Indicate "ON"(B3R3) Indicate "OFF"(B3R4) Position "OFF" 1 Pole Single Color (B3R2) Position "ON" 2 Pole Dual Color Indicate "ON"(B3R3) Indicating Color Indicating Color Position "OFF" 2 Pole Single Color(B3R2) or Indicate "OFF"(B3R4) Position "ON" 3 Pole Dual Color Indicate "ON"(B3R3) Position "OFF" 3 Pole Single Color(B3R2) or Indicate "OFF"(B3R4)...

 Open the catalog to page 9
BSB/CIRCUIT BREAKER/B3-10

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker 5.3 Flat Rocker - Form & Fit Drawings Position "OFF" Position "OFF" Position "ON" 1 Pole Single Color(B3R1) 1 Pole Dual Color(B3R6) 1 Pole With Guard LINE Position "OFF" 2 Pole Single Color(B3R1) Position "OFF" 2 Pole Dual Color Indicate "OFF"(B3R6) Position "OFF" 3 Pole Single Color(B3R1) Position "OFF" 3 Pole Dual Color Indicate "OFF"(B3R6) 2- 3.96 Notes: 1.Mounting Style:Threaded inserts,2 per pole 2.Panel Cutout Detail(Tolerance:±0.12mm) 3.All dimensions in millimeters; 4.Tolerance...

 Open the catalog to page 10
BSB/CIRCUIT BREAKER/B3-11

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker NOTE:Users can negotiate with manufacturer on the requirements for other types. NOTE:Users can negotiate with manufacturer on the requirements for other types. Bolt Type: C:Push-in stud Screw Type: Cut-out dimension 5.5 B3 series 101A-250A connection mode Multipole shunting in parallel Multipole joining-up in parallel Note: extended connection plate for the user chosing

 Open the catalog to page 11
BSB/CIRCUIT BREAKER/B3-12

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker 5.6 Dimension and installation locations of auxiliary switch 5.6.1 Auxiliary switch installation locations of handle AUX. Switch Wide of Terminal Note: auxiliary switch should be installed in the pole with handle for single handle circuit breaker which is more than 100 A 1 Pole With AUX. Switch 2 Pole With AUX. Switch 3 Pole With AUX. Switch 5.6.2 Auxiliary switch installation locations of rocker LINE 2 Pole Position "OFF" Note:You Can See The Diagram Of Aux Swith From The Back Of The...

 Open the catalog to page 12
BSB/CIRCUIT BREAKER/B3-13

ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD. Product Name B3 Series Hydraulic Electromagnetic Circuit Breaker Note:Tolerance ±0.5 Unless Otherwise Specified. Description of Rocker(B2 B3 Series) Type Angle Rocker Single Color Flat Rocker Dural Color Single Color Indicating Color Indicating Color Dural Color Indicate“OFF” With Guard Indicating Color Indicate“OFF” With Guard Single Color Dural Color Indicate“OFF” Indicating Color Single Color Dural Color Indicate“OFF” Indicating Color Horizontal LINE

 Open the catalog to page 13

All ZHEJIANG BSB ELECTRICAL APPLIANCES CO.,LTD catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.