LMG95
8Pages

{{requestButtons}}

Catalog excerpts

LMG95 - 1

Precision Power Meter LMG95 The most precise in its class. Basic accuracy 0.015% of reading + 0.01% of range Precision range DC...500kHz Analysis of devices and components in switched or modulated operation Harmonics and icker according to EN61000-3-2/-3/-11/-12

Open the catalog to page 1
LMG95 - 2

LMG95. Precise. Direct. All Waveforms The LMG95 single-phase precision power meter is an outstanding product in the proven LMG series of ZES ZIMMER® precision power measuring devices. Highly accurate continuously gapless signal measurement and processing, ergonomic operation and presentation of the results, inter- faces with high data rates for efficient system applications - these are the performance features which distinguish the LMG95. The high precision power measurements on components and devices that are required in development, quality assurance and manufacturing can be performed...

Open the catalog to page 2
LMG95 - 3

Transparency Through Real-time Visualization in the Time and Frequency Range Electronic transformer Nnrnalll nr.al Electronic 12V transformer to supply a halogen lamp. Amplitude modulated 150 kHz carrier with 100Hz envelope. Burst firing control of a hot-air fan Harmonic analysis Normal I Locll V* Uall "Li'Ha Ii per :: Triyl Active Amplitude spectrum with the help of the HRM100 harmonic analysis. The burst fire presents a 1.56Hz modulation of the carrier (50Hz mains voltage). The DC component of the spectrum results from the blower motor in half-wave operation. The extended "X-Trig" trigger...

Open the catalog to page 3
LMG95 - 4

Formula Editor, Device Settings and Fast Analog Outputs Core losses at small cos cp and high frequencies if(P>l) bell();fi J>l^— INormall Local I1* gal (with optional 500kHz precision band- width and delay compensation to 4ns) The magnetizing current I flowing in the primary winding is fed into the current input of the LMG95, and the induced volt- age at the open secondary winding is fed into the voltage input. In this way, only the core losses (magnetizing losses) are measured, and not the copper losses. The half-wave rectified voltage value, also measured with the LMG95, is a measure of...

Open the catalog to page 4
LMG95 - 5

Energy Efciency EuP - Energy using Products The directive 2005/32/EC denes ecodesign requirements for household appliances and ofce machines. It regulates the admissible energy consumption while a product is in use as well as the energy consumption during its fabrication and its disposal. In addition, the directive addresses further ecological aspects like saving resources through an economic material usage and avoiding hazardous substances. Green IT To save the environment, information technology and communications equipment has to economize on energy and resources throughout its life...

Open the catalog to page 5
LMG95 - 6

Energy Efciency The LMG95 meets these high-end requirements. LMG95 To optimize the scaling and to protect the unit, use an additional external shunt (L95-SH-xxx-P). For low currents, use the wiring for current-correct measurement. (See also into our application note #102 “Measurement of Standby Power and Energy Efciency”.) The ZES ZIMMER software CE-Test-Standby in combination with a precision power meter LMG95 or LMG500 measures the standby consumption according to the standard IEC/EN 62301. CE-Test-Standby congures and monitors the measuring devices, sets the test sequence and generates a...

Open the catalog to page 6
LMG95 - 7

Technical Data Measuring uncertainty of cos ϕ Measuring uncertainties based on: Other values 1. sinusoidal voltage and current 2. ambient temperature 23 ± 3°C 3. warm up time 1h denition of power range as the product of current and voltage range, 0 ≤ IλI ≤ 1, λ = P/S (power factor) calibration interval 12 months All other values are derived from the values for current, voltage and active power. Accuracies for the derived values depend on the functional relation (e.g. S = I * U, ∆S/S = ∆I/I + ∆U/U) Internal time base Frequency measuring 0.05Hz...500kHz ±0.01% of measuring value, measuring...

Open the catalog to page 7
LMG95 - 8

Measurement Accesories and Extensions „Plug N'Measure" current sensors for extended current ranges up to 10000A Shunt for standby measurements 0.15% DC.lOOkHz 0.15mA...lA HF-differentiaL transformer with Load resistor for almost reactionless measurement of current, e.g. at discharge Lamps. Technical data, information and selection guide in the user manual „ZES Sensors and Accessories" (available on request and at www.zes.com). Precision high voltage divider Precision high voltage divider for 3/6/9/12/30kV up to 300kHz, 0.05%. Negligible phase error, therefore best suited for wideband power...

Open the catalog to page 8

All ZES ZIMMER Electronic Systems catalogs and technical brochures

  1. DS 200

    6 Pages

  2. DS 600

    6 Pages

  3. LMG-CONTROL

    4 Pages

  4. LMG95e

    2 Pages

  5. ZES PRODUCTS

    3 Pages

  6. WCT

    2 Pages

  7. HST

    4 Pages

  8. CE-Test61k

    8 Pages

Archived catalogs