Dual Path Precision Power Analyzer with The Most Precise in its Class As Compact Desktop Device with Touch Screen
Open the catalog to page 1LMG610 – powerful, convenient, flexible Harmonics Script Editor Harmonics and interharmonics up to 2000th order, in compliance with EN61000-4-7 Flexible scripting tool for special applications Convenient calculation of all derived variables in the power analyzer Simultaneous measurement of I, V and P-variables and harmonics Presentation in tabular or graphical form Signal filters freely configurable by frequency, type and characteristics Connected current transducers are automatically configured and supplied with power Convenient commissioning with zero risk of misconfiguration Synchronize...
Open the catalog to page 2Setting the bar in power analysis For more than three decades, ZES ZIMMER with common-mode rejection? Is the mea- specifically for power measurement can re- has been focused solely on high-precision surement result still reliable for power ally satisfy these ambitious requirements. power measurement technology – so we factors in the range of 0.01? Is the earth know there is more to it than simply mea- capacitance low enough to avoid interfer- market for its extreme reliability, best-in- suring current and voltage. Anyone who ence by leakage currents? In what frequen- class accuracy, and...
Open the catalog to page 3The adequate combination of bandwidth, accuracy and costs for every application Power analyzers are available in different tinction. It is entirely possible, for instance, your needs for your particular application, accuracy classes to allow the user to choose to have need of different frequency ran- without having to accept trade-offs in ac- the right tool for the job at hand. After all, ges and accuracy levels at different points curacy or take a sledgehammer to crack a not all applications require maximum preci- in the same measurement configuration. nut, if a lower price solution could...
Open the catalog to page 4On conventional power analyzers, a signal first undergoes analog conditioning, followed by optional anti-aliasing filters, to then be fed into an A/D converter. The resulting signal can afterwards be used for the calculation of cycle-based RMS values. Alternatively it can serve as the base for an FFT or further digital filtering. Due to the limitation to a single A/D converter, there are inherently some downsides to be factored in with conventional devices. If measurements are carried out with filters active, in order to avoid aliasing with FFTs, then the wide-band values are lost. With the...
Open the catalog to page 5Precise measurements thanks to optimal alignment Accurate power measurement requires a poor utilization of measuring ranges, that 0 < λ <1. Even standby measurements and highly fine-tuned alignment of current and even a small offset can produce errors in gas discharge lamps, which are still used in voltage channels. This is where the LMG600 the magnitude of single-digit percentages. video projectors, pose no challenge for the series is setting a new global standard with At high frequencies and thus very short pe- timing differences of <3 ns. When measur- riods the phase shifts between...
Open the catalog to page 6Exact measurements without limits Although the LMG610 offers unmatched dy- configuration of the LMG610. This allows for ported measurement. Of course, other com- namic range, both in the voltage and the all of the important parameters, such as the mercially available sensors can also be used current area, there are always applications precise scaling factor, the delay compensa- with extraordinary requirements in terms tion variable, the last calibration date, and of measurement ranges. Whether you are the sensor type, to be read automatically by dealing with currents of several hundred the...
Open the catalog to page 7Switched-mode power supplies Advances in power electronics have already the downsides of their predecessors, they grid side and on the consumers‘ part. The caused the relatively large and heavy trans- also bring new challenges: for one, the cir- role of power measurement technology is former power supplies of the past to be pre- cuit feedback due to harmonics is not insig- to support the manufacturer in optimizing dominately replaced years ago by smaller, nificant and must be limited by standards their products. lighter and more efficient switched-mode power supplies. Today they can be...
Open the catalog to page 8High accuracy even at high frequencies Aliasing-free harmonic analysis up to 150 kHz Powerful FFT with up to 2,000 harmonic components High Bandwidth High Sampling Rate Lighting technology In an effort to reduce energy consumption, orescent lights („low-energy light-bulbs“) service life for their products. To achieve light bulbs are being replaced all around the are controlled by special electronic chokes. the aforementioned objective, a controlled world with ever more efficient lighting sour- Some of these chokes work with switching warm start is often performed. It must then ces. While on...
Open the catalog to page 9Technical data (summary), valid for 0 ≤ λ ≤ 1 ± (% of measured value + % of maximum peak value) Voltage USENSOR Current ISENSOR Power USENSOR / ISENSOR ± (% of measured value + % of maximum peak value) Current I* 5 mA...5 A Current ISENSOR Power U*/ I* 5 mA...5 A Power U*/ ISENSOR ± (% of measured value + % of maximum peak value) Current ISENSOR 1. Sinusoidal voltages and currents 2. Ambient temperature (23±3) °C 3. Warm-up time 1 h 4. The upper range value is defined by the maximum peak value. 5. The upper power range value is the product of upper voltage range value and upper current...
Open the catalog to page 10The full technical data can be found in the manual.
Open the catalog to page 11Current sensors LMG Test Suite The tests performed by LMG Test Suite are in accordance with the currently valid edition of EN 61000-3-2/-12 or EN 61000-3/-11, and measurements according to ECE R-10.4 Annex 11 (electromagnetic compatibility of vehicles), for example, are also possible. The LMG Remote PC software allows to easily control the LMG610 remotely from a Windows PC. Since this software mimicks the measuring device itself down to the last detail, the LMG610 can be operated as usual, even from the PC - no rethinking required, no familiarization time. © 2016 - ZES ZIMMER Electronic...
Open the catalog to page 12All ZES ZIMMER Electronic Systems catalogs and technical brochures
-
4-Channel Power Meter LMG450
8 Pages
-
Sensors and Accessories
237 Pages
-
LMG95
8 Pages
-
DS 200
6 Pages
-
DS 600
6 Pages
-
LMG-CONTROL
4 Pages
-
LMG95e
2 Pages
-
ZES PRODUCTS
3 Pages
-
WCT
2 Pages
-
HST
4 Pages
-
CE-Test61k
8 Pages
Archived catalogs
-
Products 2009/2010
2 Pages
-
Precision Power Meter LMG95
6 Pages
-
Conformity / Test System
6 Pages