DS 600 DS 600 A contact free flux gate based current measurement sensor – 600Arms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. • • • • • • 600A rms - 900A peak Maximum gain error DC to 2kHz - 0.01% Operating temperature from -40 to +85 deg Celsius Turns ratio 1:1500 Aperture size is 27.6mm Available with LEMO, BNC and DSUB output connection The sensor is a flux gate based sensor and does have an intrinsic measurement error of less than 0.5 ppm of full scale and is build in a ruggedized aluminum housing for optimal shielding against external noise and optimal cooling. Primary current peak Load resistance Power supply Overall accuracy at Nominal current Induced into primary Used on the secondary side Primary current DC Temperature -40 to 85 deg celcius 0,01% 0,5% 3% DC-100kHz Precision – Innovation www.danisense.com
Open the catalog to page 1DS 600 Absolute maximum ratings Parameter Power supply Current in calibration winding Environment and mechanical characteristics Parameter Ambient operating temperature Storage temperature Temperature derating with Iprimaryrms, ambient temperature and frequency Temperature derating of sensor 1000 Max current (Arms) 85 deg Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg Precision – Innovation www.danisense.com
Open the catalog to page 2DS 600 Accuracy data Parameter Gain / Phase (typical) Gain error - 600A 1,00% 0,50% 0,00% 10 Precision – Innovation www.danisense.com
Open the catalog to page 3DS 600 Isolation characteristics Parameter Rated isolation voltage rms, reinforced isolation IEC 61010-1 standard and with following conditions - Overvoltage category II - Pollution degree 2 Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield Impulse withstand voltage Creepage distance Comparative Tracking Index Options and ordering information Product Description Part Name Part Number DS 600 with current output in 4-pin LEMO connector DS 600 with voltage output in BNC connector DS 600 with calibration winding and...
Open the catalog to page 4Standard DSUB-9 current output When sensor is operating in normal condition the status Calibration winding and current
Open the catalog to page 5Mounting bushings on the back Precision – Innovation www.danisense.com
Open the catalog to page 6All ZES ZIMMER Electronic Systems catalogs and technical brochures
-
LMG610 Precision Power Analyzer
12 Pages
-
4-Channel Power Meter LMG450
8 Pages
-
Sensors and Accessories
237 Pages
-
LMG95
8 Pages
-
DS 200
6 Pages
-
LMG-CONTROL
4 Pages
-
LMG95e
2 Pages
-
ZES PRODUCTS
3 Pages
-
WCT
2 Pages
-
HST
4 Pages
-
CE-Test61k
8 Pages
Archived catalogs
-
Products 2009/2010
2 Pages
-
Precision Power Meter LMG95
6 Pages
-
Conformity / Test System
6 Pages