DS 200
6Pages

{{requestButtons}}

Catalog excerpts

DS 200 - 1

DS 200 DS 200 A contact free flux gate based current measurement sensor – 200Arms DS 200 is member of the small housing sensor family. The family includes 200A and 600A versions. • • • • 200A rms - 300A peak Turns ratio 1:500 Aperture size is 27.6mm Operating temperature from -40 to +85 deg celcius • Available with LEMO, BNC and DSUB output connection The sensor is a flux gate based sensor and does have an intrinsic measurement error of less than 0.5 ppm of full scale and is build in a ruggedized aluminum housing for optimal shielding against external noise and optimal cooling. Primary current peak Load resistance Power supply Overall accuracy at Nominal current Induced into primary Referred to secondary current Used on the secondary side Primary current DC Temperature -40 to 85 deg celcius 0,01 0,5 20 Precision – Innovation www.danisense.com

Open the catalog to page 1
DS 200 - 2

DS 200 Absolute maximum ratings Parameter Power supply Current in calibration winding Environment and mechanical characteristics Parameter Ambient operating temperature Storage temperature Temperature derating with Iprimaryrms, ambient temperature and frequency Temperature derating of sensor 1000 Max current (Arms) 85 deg Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg 1 10 Precision – Innovation www.danisense.com

Open the catalog to page 2
DS 200 - 3

DS 200 Accuracy data Parameter Gain / Phase (typical) Frequency Phase

Open the catalog to page 3
DS 200 - 4

DS 200 Isolation characteristics Parameter Rated isolation voltage rms, reinforced isolation IEC 61010-1 standard and with following conditions - Overvoltage category II - Pollution degree 2 Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield Impulse withstand voltage Creepage distance Comparative Tracking Index Options and ordering information Product Description Part Name DS 200 with current output in 4-pin LEMO connector DS 200 with voltage output in BNC connector DS 200 with calibration winding and current output...

Open the catalog to page 4
DS 200 - 5

Standard DSUB-9 current output When sensor is operating in normal condition the status Calibration winding and current

Open the catalog to page 5
DS 200 - 6

Mounting bushings on the back Precision – Innovation www.danisense.com

Open the catalog to page 6

All ZES ZIMMER Electronic Systems catalogs and technical brochures

  1. LMG95

    8 Pages

  2. DS 600

    6 Pages

  3. LMG-CONTROL

    4 Pages

  4. LMG95e

    2 Pages

  5. ZES PRODUCTS

    3 Pages

  6. WCT

    2 Pages

  7. HST

    4 Pages

  8. CE-Test61k

    8 Pages

Archived catalogs