Catalog excerpts
DS 200 DS 200 A contact free flux gate based current measurement sensor – 200Arms DS 200 is member of the small housing sensor family. The family includes 200A and 600A versions. • • • • 200A rms - 300A peak Turns ratio 1:500 Aperture size is 27.6mm Operating temperature from -40 to +85 deg celcius • Available with LEMO, BNC and DSUB output connection The sensor is a flux gate based sensor and does have an intrinsic measurement error of less than 0.5 ppm of full scale and is build in a ruggedized aluminum housing for optimal shielding against external noise and optimal cooling. Primary current peak Load resistance Power supply Overall accuracy at Nominal current Induced into primary Referred to secondary current Used on the secondary side Primary current DC Temperature -40 to 85 deg celcius 0,01 0,5 20 Precision – Innovation www.danisense.com
Open the catalog to page 1DS 200 Absolute maximum ratings Parameter Power supply Current in calibration winding Environment and mechanical characteristics Parameter Ambient operating temperature Storage temperature Temperature derating with Iprimaryrms, ambient temperature and frequency Temperature derating of sensor 1000 Max current (Arms) 85 deg Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg 1 10 Precision – Innovation www.danisense.com
Open the catalog to page 2DS 200 Accuracy data Parameter Gain / Phase (typical) Frequency Phase
Open the catalog to page 3DS 200 Isolation characteristics Parameter Rated isolation voltage rms, reinforced isolation IEC 61010-1 standard and with following conditions - Overvoltage category II - Pollution degree 2 Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield Impulse withstand voltage Creepage distance Comparative Tracking Index Options and ordering information Product Description Part Name DS 200 with current output in 4-pin LEMO connector DS 200 with voltage output in BNC connector DS 200 with calibration winding and current output...
Open the catalog to page 4Standard DSUB-9 current output When sensor is operating in normal condition the status Calibration winding and current
Open the catalog to page 5Mounting bushings on the back Precision – Innovation www.danisense.com
Open the catalog to page 6All ZES ZIMMER Electronic Systems catalogs and technical brochures
-
LMG610 Precision Power Analyzer
12 Pages
-
4-Channel Power Meter LMG450
8 Pages
-
Sensors and Accessories
237 Pages
-
LMG95
8 Pages
-
DS 600
6 Pages
-
LMG-CONTROL
4 Pages
-
LMG95e
2 Pages
-
ZES PRODUCTS
3 Pages
-
WCT
2 Pages
-
HST
4 Pages
-
CE-Test61k
8 Pages
Archived catalogs
-
Products 2009/2010
2 Pages
-
Precision Power Meter LMG95
6 Pages
-
Conformity / Test System
6 Pages