Catalog excerpts
EXP-AIN User Manual For more details, visit: www.zerynth.com This Document is the property of Zerynth (Zerynth S.r.l.). Duplication and reproduction are forbidden if not authorized. Contents of the present documentation refers to products and technologies described within. All technical data contained in this document may be modified without prior notice The content of this documentation is subject to periodic revision.
Open the catalog to page 1Table of contents Overview Modular Expansion System General Characteristics Screw Description Technical Specifications
Open the catalog to page 2Overview The EXP-AIN expansion board enables monitoring and controlling of industrial processes using 8 industrial analog sensor channels.The channels support voltage-based ( ±10V), current-based (±20mA) or resistive sensors . Zerynth expansion boards work seamlessly with all of the Zerynth Development boards. Combined, they can act as a Development Board for prototyping a Product, and a core for industrial applications. Modular Expansion System Zerynth Development boards offer a game-changing way of connecting and adding functionalities to your application in a simple and easy way. The...
Open the catalog to page 3General Characteristics 8 Analog Channels: Each channel can be configured as ○ 4-20 mA Current channel (full input range +/-20mA) 0-10V Voltage channel (full input range +/-10V) Resistive Sensor Channel: Internal bias is designed for NTC thermistor probes rated 10kΩ @ 25°C (with B=3435), but other probes may also be used depending on the temperature range to be measured. Current Clamp channel based on voltage or current signal( within channel Voltage and current ratings). Screw Description P1 - Upper screw terminal Screw Number Analog Input Channel 4-20mA/0-10V/Resis./Current Analog Input...
Open the catalog to page 4Isolated Ground reference for analog bias NOTE: All I/O pins on screw terminals are isolated from the zBUS interface. ● Overvoltage Cat.II / Pollution Deg.II NOTE: Analog channel to channel isolation > 250kΩ Technical Specifications Environmental Conditions Temperature Storage Temperature Degree Protection Dip-Switches Rotary Switch SW1 : Chooses the address of the ADC Chip. Enable multiple boards to be connected simultaneously. Position Rotary Switch SW2 : Controls which hardware channel you want to link the interrupt. Position
Open the catalog to page 5S1 Switch : Each Analog channel can be configured with 3 DIP switches that enable specific features, The same settings are applied for S2, S3, S4. PIN AINx read as voltage AINx read as Current AINx read as resistive sensor AINy read as voltage AINy read as Current AINy read as resistive sensor Each Switch controls two ADC channels as follows ● For Voltage measurement - 0 10V standard industrial voltage sensor (Select switch number n according to the needed analog channel): Switch pin For Current measurement - 4-20 mA standard industrial sensor: Switch pin
Open the catalog to page 6NOTE: Current clamp (transformer) can be connected using the 4-20mA configuration of the DIP switches, exploiting the full input range of ±20mA. That is ±2V across the on-board 100 Ohm resistor, which cannot handle power dissipation required by ±10V. Current transformer turns ratio must be chosen so that the secondary current does not exceed 20mA. NOTE: All input/Output pins on this board have a max voltage rating of 36V across positive/negative pairs. Power Supply: The board is powered by the 5V internal signal from the ZM1 Development board. zBUS Pin Description PIN-Name
Open the catalog to page 7External power supply voltage (9-36V) enable/disable the power in the zBUS Regulated 5V power supply Configurarable interrupt for DB-ZM1 on-board port expander. Regulated 3.3V power supply. Configurarable interrupt for DB-ZM1 on-board port expander. Digital I/O pins connected to ZM1 on-board Port Expander Native Interrupt: user configurable SPI Master Input Slave Output SPI Master Output Slave Input UART/USART 1 Transmit Data UART/USART 1 Receive Data UART/USART 1 Request To Send UART/USART 1 Clear To Send UART/USART 2 Transmit Data UART/USART 2 Receive Datal UART/USART 2 Request To Send...
Open the catalog to page 8Software Zerynth SDK provides software libraries for each board, alongside API documentation and examples. Please check the Hardware section for more information. https://docs.zerynth.com/latest/hardware/ Zerynth SDK Zerynth platform is designed to simplify and accelerate the development of IoT applications. Zerynth offers tools for developers, system integrators, and businesses to enable IoT for their products, rapidly in a secure and connected way. Zerynth SDK is the official development framework for Zerynth hardware, It includes a compiler, device drivers and libraries drivers, In...
Open the catalog to page 9Declaration of Conformity IMPORTANT: KEEP THESE INFORMATION FOR FUTURE REFERENCE FOR FULL SET UP AND INSTALLATION INSTRUCTIONS PLEASE VISIT docs.zerynth.com All external power supplies used with Zerynth boards must comply with the relevant regulations and standards applicable in the country of use and must provide a voltage between 9 and 36 VDC. The manufacturer cannot guarantee compliance with the RED directive if the end user uses custom circuits other than those supplied by Zerynth (used in conformity tests). All expansion boards that require CE marking have been tested and meet the...
Open the catalog to page 10EN - Waste Electrical and Electronic Equipment (WEEE) Symbol The use of the WEEE symbol indicates that this product/board may not be treated as household waste. By ensuring this product/board is disposed of correctly, you will help protect the environment. For more detailed information about recycling of this product/board, please contact your local authority, your household waste disposal service provider or the shop where you purchased it.
Open the catalog to page 11