ZPS Series
1 /2Pages

ZPS Series

ZPS Series
1 /2Pages

Catalog excerpts

ZPS Series-1

Laboratory Power Supplies ZPS Sries Single Output Output power up to 10 kW Voltage and current regulated Primary switched mode Master - slave - operation possible Programming current - voltage 19" rack mounting extremely compact and ruggedly designed Option: Installed Interface Euro Card IEEE 488.2 (GPIB)/RS232 with Lab View Driver INT2E series Integrated USB1.1 interface with driver software External CAN Open Interface (on request) ce s n TO O r o n TO Input voltage ZPS3: 230 V ±10% 1 phase 50 / 60 Hz ZPS6/ZPS10: 400 V ±10% 3 phase 50 / 60 Hz < 5 A ZPS3: 0,99 EMC: Input EMI filter Input immunity Operating and Contro Programming analog Programming digital only with Option INT2 EN61000-6-4 EN61000-6-2 o H w c Inrush current Power factor Output:: Output voltage (DC) Output current Efficiency Regulation: Line regulation (AC line change 10%) Load regulation (99 % load change) Stability after 8 h working time and const. ambient temp. Dynamic response set in U-const. Mode voltage and current: 0 - 10 V = 0 - 100 % U t , I t out ' out Contol: U und I nominal value presetting U and I Monitor signals, Power ON/OFF, isolated Bus - signals and analog signals; isolation between digital signals; SCPI-programmable (IEC625-2); programming of analog value with absolute values max. three same units 3 units with same Uout out same units (total voltage < 150 V) standard voltage and current, LED, 3% digits voltage and current 10 - turn potentiometer see table see table > 80 % voltage 0,1 % Uo current 0,1 % I ° ' out voltage 0,1 % Uo current 0,1% Iouot ' out 0,1% Master - slave - mode Parallel operation Series operation Remote sense Instruments Adjustment < 2 ms at load change 1 % - 100%, nominal value change 1%-100%, neg. nominal value change 100% - 80% (at I > 100 A) 0,5% Imax, Umax 0,1% < 0,5% Umax voltage: 0,05% / K current: 0,1%/K shut down Absolute accuracy Reproducibility Ripple and noise Temperature coefficient AC-line undervoltage protection Protection: Overload protection Thermal protection Undervoltage protection Environmental Conditions: Operating temperature Derating from + 40 - + 70°C Cooling ctors: Cable (6m) with CEE- Connector 16A or 32A ZPS 3: Cable (6m) with schuko connector Copper bars rear side Input Output Physical Specifications: Dimensions short circuit protection shut down, auto recover shut down ZPS3/ZPS6: 19", 3 U, depth 400 mm with connections 450 mm ZPS10: 19", 6 U, depth 420 mm with connections 470 mm ZPS3 19 kg ZPS6 21 kg ZPS10 32 kg 0 - + 40°C int. fans, temperature controlled Weight Safety standard Isolation input - output: input - ground: output - ground: EN60950-1 Uout < 200 V: 3,7 kVrm out rm 2,2 kV ' rms Uout < 60 V: 500 Vrms out rms U t > 60 V: 1,35 kV zentro-elektrik Gmb I Tel.: ++49 (0) 7232-31310 I Fax: ++49 (0) 7232-3131399 I E-mail: [email protected] 1/27

 Open the catalog to page 1

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.