1. Catalogs
  2. Zentro-Elektrik
  3. EL10000, EL20000 Series

EL10000, EL20000 Series
1 /2Pages

EL10000, EL20000 Series

EL10000, EL20000 Series
1 /2Pages

Catalog excerpts

EL10000, EL20000 Series-1

Electronic DC Load EL10000, EL20000 Sries Power 10000 W and 20000 W Cooled by cooling liquid Constant I-Mode, U- Mode P- Mode or G- Mode All Modes ext. programmable Nominal value indication and offline setting of all Modes Auto change to true values Stand-alone use and intended for 19" rack Options a.o.: Installed IEEE488.2 (GPIB) / RS232* / USB* interface with Lab-View Driver (Series INT2E) Installed USB Interface with driver software External CAN Open Interface (on request) *selectable RS232 or USB Input: Ci C ry o r o b a L Operation and Control: Manual adjust: Adjustment current, voltage, power and conductance (see table): each 2 levels (max., min.) each over 2 channels adjustable selectable I-Mode 20/100%, G-Mode 5/100% 100 Hz or 1 kHz switch-selected, waveform: square-wave 1 : 1 ext. voltage (reference - UL) 0 - 10 V = 0 - Imax 0 - 10 v = 0 - Umax 0 - 10 v=0 - Pmax 0 - 10 v=0 - Garni, any waveform, frequency range 0 - 5 kHz (-3 dB) same units current-, voltage-, power- and conductance-monitor, signal undervoltage, sum alarm signals for overcurrent, temp. limit, overload or overvoltage overcurrent, temp. limit, overload, over- and undervoltage each 1 LED for voltage, current/conductance and power LED digital 3% dig., accuracy 0,2% ± 1d o H W c Input voltage 230AC V ±10%, 50 - 60 Hz see table see table see table Load voltage Load current Power Regulation: Set point accuracy (Voltage range ± 20%) Rise time (10 - 90% nominal value change) Temperature coefficient (after 15 min. working time, const. ambient temp. and const. input voltage) Protection: Overload protection Overvoltage protection Thermal protection Overcurrent Safety for load circuit and reverse polarity protection Environmental Conditions: Humidity Operating temperature Cooling Coolant pressure Coolant temperature < 0,1 % Imax, Um < 1% G ma, P " mar ma. typ. 100 n s < 0,1%/K I ma within 8 hours Pulse-generator I, U, P, G Programming power limit Pmax + 5 % power shutdown ULmax + 5% power shutdown, manual reset current limit Imax + 20% fuse and wattless current diode forr IL < 400 A Parallel operation Monitor Signals max. 70%, non condensing +15°C - +35°C cooling liquid, temp. controlled 3 bar < P < 6 bar + 12°C < » < +20°C Indication Instruments Safety standard Isolation AC input - load input: AC input - ground: Load input - ground: EN 61010-1 Input Euro - plug rear side with switch front side type DIX SE50 female plug included IL > 250 A contact rail each pole 2 x M10 25 pole Sub D female plug R 3/4 AG Load UL < 350 V: 2,3 kVeff UL > 350 V - 800 V: 3,7 kVeff 1,35 kVeff UL < 150 V: 500 Veff ULL > 150 - 300 Ve:f f820 Veff L eff UL > 300 - 600 V: 1,35 kVeff UL > 600 - 800 V: 2,2 kVeff Ext. programming Coolant Physical Specifications: Dimensions w x h x d Weight Input EMI filter Input immunity EN61000-6-3 EN61000-6-1 520 x 305 x 760 mm EL10 000: ca. 45 kg EL20000: ca. 65 kg zentro-elektrik Gmb I Tel.: ++49 (0) 7232-31310 I Fax: ++49 (0) 7232-3131399 I E-mail: [email protected]

 Open the catalog to page 1

All Zentro-Elektrik catalogs and technical brochures

  1. ZAS Series

    3  Pages

  2. ZPS Series

    2  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.