zelsius® C5-CMF_2021

zelsius® C5-CMF_2021

zelsius® C5-CMF_2021

Product catalog summary
Overview: The zelsius® C5-CMF is an electronic compact measuring capsule meter designed for heat and cold energy measurement. It is compatible with connection interfaces as per DIN EN ISO 4064-4 and offers optional interfaces such as M-Bus, wireless M-Bus, and LoRaWAN®.
Specifications:
  • Nominal Sizes: qp 0.6 / 1.5 / 2.5 m³/h
  • Flow Sensor: Electronic, non-reactive impeller scanning with metrological approval for horizontal and vertical installation.
  • Temperature Range: CMF: 10°C to 90°C, ASF: 15°C to 90°C
  • Pressure Loss: ≤ 0.25 bar at nominal flow
  • Measurement Accuracy: Class 3
  • IP Protection Class: 54 (65 for heating and cooling energy metering)
Features:
  • Removable calculator with a cable length of approx. 1.2 m for flexibility in tight spaces.
  • Compatible with various commercially available connection interfaces.
  • Optional data communication interfaces include M-Bus, wireless M-Bus, and LoRaWAN®.
  • Automatic switching for combined heat/cooling energy measurement.
Technical Data:
  • Temperature Sensors: Platinum precision resistor Pt 1000, with a temperature range of 0°C to 105°C or 0°C to 150°C.
  • Calculator: Temperature range of 0°C to 105°C, with a display range of LCD 8-digit + additional character.
  • Data Storage: Daily data storage with monthly readings.
  • Battery: 3.6 V lithium battery with a lifetime of over 6 years, optionally over 11 years.
Installation:
  • Suitable for horizontal, horizontal tipped through 90°, and vertical installation positions.
  • Installation point options include return flow and optionally forward flow.
Compatibility: The zelsius® C5-CMF is compatible with various manufacturers and models, including Allmess, Elster, Engelmann, Sensus, and others, with specific thread types and sizes.
Additional Versions: Other versions include zelsius® C5-IUF with ultrasonic flow sensor and zelsius® C5-ISF with single-jet flow sensor.
See more

Catalog excerpts

zelsius® C5-CMF_2021-1

Technical data sheet zelsius® C5-CMF Electronic compact measuring capsule meter for heat and cold energy suitable for connection interfaces according to DIN EN ISO 4064-4 Optional interfaces: M-Bus, wireless M-Bus, LoRaWAN® and 3 inputs/outputs Nominal sizes: qp 0.6 /1.5 /2.5 m³/h The new zelsius® C5-CMF with measuring capsule flow meter combines compactness with rugged construction. The calculator on the zelsius® C5-CMF is removable as standard with a cable length of approx. 1.2 m and provides a real practical advantage in tight spaces and transfer stations with covers. A matching wall adapter with mounting hardware is included in the delivery. The flow sensor on the zelsius® C5-CMF has electronic, non-reactive impeller scanning and has metrological approval for horizontal and vertical installation (downpipe and riser) according to the current European Measuring Instruments Directive 2014/32 /EU (MID). The zelsius® C5-CMF is ideally suited for continuous use during regular meter replacement as well as for installation in pre-equipped single-pipe connectors (EAS) in new measuring points thanks to the large selection of directly compatible and commercially available connection interfaces. System components for remote meter reading, customer service and MID compliant accessories for the direct installation of temperatures make the zelsius® C5-CMF an optimal solution for practical use. The advantages of the zelsius® C5-CMF at a glance ■■ Directly compatible with many commercially available connection interfaces in accordance with DIN EN ISO 4064-4 (formerly DIN EN 14154) Standard removable calculator, connection cable length to the flow sensor approx. 1.2 m for high flexibility in tight installation situations With optional contemporary data communications interfaces by wire (M-Bus) or wireless M-Bus in accordance with the Open Metering System (OMS) as well as three programmable pulse inputs and outputs Available as combined heat/cooling energy meter wi

 Open the catalog to page 1
zelsius® C5-CMF_2021-2

Technical data sheet zelsius® C5-CMF Technical data flow sensor CMF (Values for symmetrical installation of temperature sensor pair) Nominal flow qp Starting flow horizontally ca. Minimum pressure (to avoid cavitation) Connecting sizes Nominal flow Meassurement accuracy class Threaded connection Installation length Threaded connection Connecting point type Nominal pressure / peak pressure 54 ( 65 for heating and cooling energy metering) Installation position horizontal, horizontal tipped through 90°, vertical Installation point return flow optionally forward flow m Cable length up to calculator...

 Open the catalog to page 2
zelsius® C5-CMF_2021-3

Technical data sheet zelsius® C5-CMF Technical data calculator Technical data temperature sensors Temperature range Temperature difference range Platinum precision resistor Display range Ambient temperature Resolution frequency Sensor type Measurement frequency s Heat consumption display Data storage Supply Battery lifetime Stores monthly readings during the whole running time extensive storage of flow rate, perfomance and other parameters optical interface Standard (ZVEI, IrDA) ■■ inputs/outputs 3 ■■ -Bus (The current consumpM tion in the connectionon on the M-Bus level converter: < 1,5 mA),...

 Open the catalog to page 3
zelsius® C5-CMF_2021-4

Technical data sheet zelsius® C5-CMF Exchange options for existing meters Type Ista IST, G2″ Type Allmess ASF/CMF (A1), M77x1,5 Installation of temperature sensor Installation with existing ball valves with adapter Installation with existing immersion sleeves Temperature sensor DS 27,5 („AGFW-sensor“) or DS 6

 Open the catalog to page 4
zelsius® C5-CMF_2021-5

Technical data sheet zelsius® C5-CMF Extract from the overview of exchange possibilities ISTA (Viterra) Landis & Staefa

 Open the catalog to page 5
zelsius® C5-CMF_2021-6

Technical data sheet zelsius® C5-CMF ZENNER International GmbH & Co. KG Römerstadt 6 66121 Saarbrücken Germany Phone +49 681 99 676-30 Fax +49 681 99 676-3100 E-Mail [email protected] Internet www.zenner.com zelsius® C5-IUF Compact meter with ultrasonic flow sensor (IUF) Subject to technical modifications. We accept no liability for any errors or misprints. ZRI_SAP163936_191002_EN zelsius® C5-ISF Compact meter with single-jet flow sensor (I

 Open the catalog to page 6

All Zenner InternationalGmbH & Co.KG catalogs and technical brochures

  1. MTKD-M-ST

    2  Pages

  2. MTKD-M-FA

    2  Pages

  3. MTWD-M-CC-ST

    2  Pages

  4. MTWD-M-CC-FA

    2  Pages

  5. MNK-RP-N

    4  Pages

  6. MNK-L-RP-N

    2  Pages

  7. Minomess®

    4  Pages

  8. RNK-RP-N

    4  Pages

  9. multidata

    2  Pages

  10. AMR Systems

    22  Pages

  11. PDC

    4  Pages

  12. Gas Meters

    40  Pages

Archived catalogs

  1. caltos E

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.