better together POLYETHYLENE LIFTING STATIONS FOR CIVIL AND INDUSTRIAL INSTALLATIONS
Open the catalog to page 1better together Polyethylene lifting stations for civil and industrial installations The increasing use of underground spaces, such as toilets, garages and car parks in new urbanisation or building redevelopment projects, often requires the use of systems to collect wastewater and lift it to a higher level. The liftBOX lifting stations are designed to collect rainwater, wastewater or sewage and transfer it to a higher level, which would otherwise be unreachable due to the distance or by gravity, delivering it to the sewage line or the treatment plant. The lifting stations consist of a...
Open the catalog to page 2Specifications • Roto-moulded polyethylene tank • Constant, thick walls with horizontal reinforcing ribs • Contoured bottom to prevent stagnation and facilitate positioning of the pump • Rated volume from 650 to 19000 litres • Inlet pipe diameter from DN 125 to DN 400 • Outlet diameter from DN 50 to DN 150 • Optional inlet effluent filter basket (models M and L only) • Valve chamber separate from tank compartment (models M and L only) Advantages over conventional lifting stations with concrete tanks • Lower weight and lower transport costs • Faster installation • Shorter settling and drying...
Open the catalog to page 3better together Constructive details liftBOX S Electrical control panel for managing the lifting station (available separately) Polyethylene outlet pipe Pedestrian cover made of polyethylene, Ø600 mm Hermetically sealed with a gasket. Eyelets integrated in the structure Provision for inflow inlet pipe Cast-iron check valve with NBR rubber sinking ball shutter. Full free passage. Tank polyethylene with horizontal reinforcing ribs Starting and stopping floats The bottom coupling device (DAC) is designed to allow the pump to be replaced quickly, even when the tank is full Lifting station...
Open the catalog to page 4Optional accessories Extension Extension for easy connection of the tank to the ground level. Pedestrian cover. H300 mm - Ø620 mm Rated dimensions with rounded values RATED volume (litres)
Open the catalog to page 5better together Constructive details liftBOX M / liftBOX L Pedestrian cover with pressure closure Dimensions 770x550 mm each. Hermetically sealed with a gasket. Electrical control panel for managing the lifting station (available separately) Manhole covers Fall protection grating Eyelets integrated in the structure Polyethylene outlet pipe Stainless steel guide pipes Provision for inflow inlet pipe Inlet effluent filter basket 3 The bottom coupling device (DAC) is designed to allow the pump to be replaced quickly, even when the tank is full Frame steel for fixing to reinforced concrete slab...
Open the catalog to page 6Separate valve operating chamber Each lifting station can be equipped with a valve chamber with an independent, snap-closing cover. This allows access to the valves without opening the main tank. For each pressure line, the valve chamber comprises a cast-iron knife gate valve complete with handwheel control and a check valve with cast-iron body and full free passage NBR rubber sinking ball. On model L versions, there is an additional knife gate valve for emptying the main manifold in case of maintenance work on the flow line. Optional accessories 1 Fall protection grid Fall protection...
Open the catalog to page 7better together Range and dimensions liftBOX L RATED volume (litres) Other liftBOX M models with intermediate capacities are available on request RATED volume (litres) Rated dimensions with rounded values
Open the catalog to page 8Installation The liftBOX lifting stations are designed for underground installation. Installation and assembly are not critical but must be carried out professionally to ensure perfect operation and longlasting use of the system. Zenit technicians can provide advice and assistance during all phases of the process, from pre-sales to final testing. Refer to the manual supplied with the product for laying and installation. Contact Zenit or experienced technicians, if necessary. The Works Management is responsible for execution. Site preparation and positioning The installation site must be...
Open the catalog to page 9better together Grey series Versatile and compact submersible electric pumps Used for drainage groundwater and first rainwater, lifting fouled biological liquids and sewage in civil and industrial plants, wastewater treatment plants and process water also containing fibres or filamentous bodies, livestock farms. Thermal protections (Klixon) integrated in the stator Cast-iron structure Insulation class H (180°C) IP 68 protection rating AISI 431 drive shaft Two SiC mechanical seals in the oil chamber Outlet DN32 - DN250 Water infiltration probes of the mechanical seal oil chamber Models DGG...
Open the catalog to page 10Electronic and electromechanical panels The electric control panel, available separately, are the "brains" of the lifting station. It allows the automatic start-up of the pumps using float switches and the management of any alternation cycles. The installation of the acoustic and/or visual alarm module enables the signalling of any anomalies or malfunctions, such as the risk of overflowing, impeller blockage or water entering the mechanical seal chamber. Standard electronic boards Electronic control panels suitable for managing 1 or 2 single-phase electric pumps with a power rating of 0.37...
Open the catalog to page 11better together For further information, visit www.zenit.com The data provided are not binding. Zenit reserves the right to modify the product without advance notification. The digital version of this catalogue is available for download at: www.zenit.com/download
Open the catalog to page 12All Zenit catalogs and technical brochures
-
pumpBOX Lifting Stations
8 Pages
-
Aeration and Mixing systems
16 Pages
-
Product overview
8 Pages
-
Grey Series
12 Pages
-
ZM Mixing systems
8 Pages
-
blueBOX Lifting Station
8 Pages
-
Uniqa Chopper Series
8 Pages
-
Reference Book
216 Pages
-
Company Profile
6 Pages
-
Steel Series
2 Pages
-
Flood Pump Kit
2 Pages
-
Molib-tech hardening process
2 Pages
Archived catalogs
-
Domestic-Residential Catalogue
84 Pages
-
Industrial & Civil
88 Pages