1. Catalogs
  2. Yueqing RunEasy Electronic Technology Co.,Ltd.
  3. Three phase 120A latching relay TP41-10A

Three phase 120A latching relay TP41-10A

Three phase 120A latching relay TP41-10A

Three phase 120A latching relay TP41-10A

Product catalog summary
Specifications
  • Coil Voltage Options: 6V, 9V, 12V, 18V, 24V, 48V DC
  • Contact Material: AgSnO2
  • Maximum Current: 120A
  • Maximum Power: 30000VA
  • Operating Temperature Range: -40℃ to +85℃
Procedures and Standards
  • Conforms to IEC62055-31 (UC2 and UC3) for fault making capacity and short-circuit current carrying capacity.
  • Electrical endurance testing follows IEC62055-31 UC3 requirements, with inductive load testing conducted after resistance load testing.
Characteristics
  • Three-phase 120A switching capability.
  • Multi-layer blades for low temperature rise.
  • Environmentally compliant with ROSH standards.
Ordering Information
  • Standard windings available for various voltages, with special ordering allowed for other nominal voltages.
Electrical Endurance
  • Power factor for 220VAC 120A is 10:20UC3 with cosφ=1.0 and cosφ=0.5.
Additional Notes
  • Contact resistance is 1.0mΩ Max.
  • Maximum voltage is 253V AC.
  • Outline dimensions and circuit diagrams are provided for installation guidance.
See more

Catalog excerpts

Three phase 120A latching relay TP41-10A-1

Relay Technical Data Description ● Three phase120A Switching Capability; ● Multi-layer blades,Low temperature rise; ● Conform to fault making capacity and short-circuit current carrying capacity requirement of IEC62055-31(UC2 andUC3); ● Environment protection (Comply with ROSH); Ordering information Ordering information Contact Material: AgSnO 2 Part No.: Three phase 120A Switching D: Double Coil S: Single Coil Type: Magnetic latching relay Contact data Contact Contact data Contact Contact arrangement

 Open the catalog to page 1
Three phase 120A latching relay TP41-10A-2

Standard windings NOTE: Others norminal voltage required, special ordering allowed. Characteristics 1000MΩ Between Open Contact 8 mm 147m/s2 10HZ-55HZ amplitude 1.5mm -40℃…+85℃ Electrical Endurance Power factor UC 3 NOTE: Electrical endurance confirm to IEC62055-31 UC3 testing requirement, do the inductive load testing after the resistance load te