Specifications:
  • Coil Voltage Options: 6V, 9V, 12V, 18V, 24V, 48V DC
  • Contact Material: AgSnO2
  • Contact Arrangement: 1A(B)
  • Maximum Voltage: 253V
  • Maximum Current: 100A
  • Maximum Power: 25300VA
  • Electrical Endurance: Conforms to IEC62055-31 UC3
  • Operating Temperature Range: -40℃ to +85℃
Procedures and Standards:
  • Complies with ROSH for environmental protection.
  • Electrical endurance testing follows IEC62055-31 UC3 requirements, with inductive load testing conducted after resistance load testing.
Characteristics:
  • Single Phase 100A Switching Capability
  • Multi-layer blades for low temperature rise
  • Magnetic latching relay type
  • Electrical endurance: 51×104 OPS
  • Mechanical endurance: 41×104 OPS
Ordering Information:
  • Standard windings available for various voltages, with special ordering allowed for other nominal voltages.
Additional Notes:
  • Contact resistance is 1.0mΩ Max.
  • Insulation resistance is 1000MΩ.
  • Between open contact distance is 8 mm.
  • Shock resistance is 147m/s2.
  • Vibration resistance is 10HZ-55HZ with amplitude 1.5mm.
See more

Catalog excerpts

Single phase 120A latching relay TP41-23A-1

Relay Technical Data Description ● Single Phase 100A Switching Capability; ● Multi-layer blades, Low temperature rise; ● Environment protection (Comply with ROSH); ● Conform to IEC62055-31 UC 3; Contact Material: AgSnO 2 Part No.: Single phase 100A Switching D: Doulbe Coil S: Single Coil Type: Magnetic latching relay Contact data Contact Contact data Contact Contact arrangement

 Open the catalog to page 1
Single phase 120A latching relay TP41-23A-2

Standard windings NOTE: Others norminal voltage required, special ordering allowed. Characteristics 1000MΩ Between Open Contact 8 mm 147m/s2 10HZ-55HZ amplitude 1.5mm -40℃…+85℃ Electrical Endurance Power factor UC 3 NOTE: Electrical endurance confirm to IEC62055-31 UC3 testing requirement, do the inductive load testing after the resistance load te

 Open the catalog to page 2
Single phase 120A latching relay TP41-23A-3

Outline dimensions and circuit diagram

 Open the catalog to page 3

All Yueqing RunEasy Electronic Technology Co.,Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.