Catalog excerpts
Miniature Circuit Breaker Technical Specification Pole Rated voltage(V) Rated current(A) Rated short-circuit breaking capacity BT01 2PMiniature Circuit Breaker BM Technical Specification Pole 1P, 2P, 3P Rated short-circuit breaking capacity 4 5kA,3kA Circuit Breaker
Open the catalog to page 1Miniature Circuit Breaker Bote wo”Miniature Circuit Breaker BS BS1P+N Technical Specification Pole 1P.2P.3P.1P+N Rated short-circuit breaking capacity 10kA,5kA,3kA Miniature Circuit Breaker BG Technical Specification BG01 2P
Open the catalog to page 2Electrical Accessories Electrical Accessories OF Auxiliary Switch Character: Used to indicate the "On" or "Off" position of circuit breaker Assembly: Installed on the left side of circuit breaker. Application: Used to indicate the "On" or "Off position of circuit breaker, the signals can be seen on the case or its front or on the operating stage. It is can be connected with SD alarm auxiliary switch. Botevo Shunt trip -22.1113V • 22-60V I Res«! i V* J $ SW*®1* SD Alarm Auxiliary Switch Character: Used to indicate the "Off" position of circuit breaker. Assembly: Installed on the left side of...
Open the catalog to page 3Residual Current Device Residual Current Device Residual current device is a generic term covering both RCCBs and RGBOs. A residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly...
Open the catalog to page 4Residual Cuirent Device Residual Current Operated Circuit BreakerTechnical data Standard Type (wave form of the earth leakage sensed) Rated residual making and breaking capacity I Am Short-circurt current lnc=IAc SCPD fuse break time under I An <04 (Normal type), l0ms~30ms(G type). i50ms~500ms(Stype) Rated frequency Rated impulse withstand voltage(l .2/50) Uimp Dielectnc test voltage at ind. Freq. for 1 min Pollution degree Electrical life Mechanical life Circuit Breaker Mechanical features Fault current indicator Protection degree Ambient temperature {with daily average<35t:) Storage...
Open the catalog to page 5Residual Current Device Electromagnetic AC/A Electronic AC IEC/EN 61008-1 10kA, 6kA Note: Bectromagnetic type & electronic type are both available. Http://www.bolevo.com E-maikinfo@bolevo.com
Open the catalog to page 6Residual Cuirent Device Residual Current Operated Circuit Breaker L7 Electromagnetic AC/A Electronic AC IEC/EN 61008-1 6kA,3kA Note: Electromagnetic type & electronic type are both available.
Open the catalog to page 7Residual Current Device BolcvoResidual Current Operated Circuit Breaker F362/F364 Model: F3E2-2P Note: Electromagnetic type & electronic type are both available. Http://www.bolevo.com E-maikinfo@bolevo.com
Open the catalog to page 8Residual Cuirent Device Bote i/o Residual Current Operated Circuit Breaker L5 Electromagnetic AC/A Electronic AC IEC/EN 61008-1 10kA,6kA
Open the catalog to page 9Residual Current Device BolcvoResidual Current Operated Circuit Breaker L4 Electromagnetic AC Electronic AC IEC/EN 61008-1 6kA,3kA Electromagnetic AC Electronic AC IEC/EN 61008-1 6kA,3kA Note: Electromagnetic type & electronic type are both available. Circuit Breaker Http://www.bolevo.com E-maikinfo@bolevo.com
Open the catalog to page 10Residual Cuirent Device Bote i/oResidual Current Operated Circuit Breaker FIN Electromagnetic AC Electronic AC IEC/EN 61008-1 6kA,3kA Note: Bectromagnetic type & electronic type are both available.
Open the catalog to page 11Residual Current Device Bolcvo Moulded Case Circuit Breaker PG230/PG430 Http://www.bolevo.com E-mail:mfo@ bolevo.com
Open the catalog to page 12Residual Cuirent Device Bote i/o Residual Current Operated Circuit Breaker with Over-current Protection Function Personnel and fire protection Cable and line protection against overload and short-circuits. Selection lAn = 30 mA: additional protection in the case of direct contact. C curve (5-10 In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current AC class - Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase.
Open the catalog to page 13All Yueqing Hean Electrical Co. catalogs and technical brochures
-
CurrentTransformer
9 Pages
-
SwitchPowerSupply
7 Pages
-
PowerInverter
5 Pages
-
DoorBell
6 Pages
-
CableTieClip
19 Pages
-
voltage stabilizer
12 Pages
-
Transformer
9 Pages
-
Metal Cabinet
19 Pages
-
Surge Protective Device
3 Pages
-
2014
8 Pages