eyc-tech FTM06D Thermal Mass Flow Transmitter
6Pages

{{requestButtons}}

Catalog excerpts

eyc-tech FTM06D Thermal Mass Flow Transmitter - 1

Hot Wire Thermal Air Velocity Transmitter Thermal mass flow sensor Can measure air velocity and air volume Multiple output option : 4 ... 20 mA / 0 ... 10 V / RS-485 / Frequency / Pulse ( Option ) Built-in temperature compensation, accurate measurement Using constant temperature anemometer(CTA) technology, good sensitivity Unit setting : [m/s], [ft/s], [Nm3/h], [L/min], [°C], [°F] Strong stainless steel housing, for a variety of harsh environments FTM06D is based on thermodynamic principle, can measure air velocity and air volume, there are 2 temperature sensors inside the probe : one for temperature measurement, the other one as a measuring conveyor after heated. Temperature difference between the two as a basis for measuring flow rate. When the medium flow rate increases, the temperature difference decreases. The temperature difference converted to standard signal output after processed that is why flow rate can be measured by these two sensors. All-metal housing, suitable for a variety of pipe diameters. Semiconductor / Electronics / Papermaking / Food / Pharmaceuticals / Biotechnology industry / Plant CDA system / Refrigerated dryer adsorption / PSA nitrogen(N

Open the catalog to page 1
eyc-tech FTM06D Thermal Mass Flow Transmitter - 2

Thermal mass flow sensor Minimum initial value Measuring range Installation angle effect Output signal Power supply Electrical connection Pulse ( 1 ... 100 l/pulse, option ) About 60 sec Electrical protection Inline type Load resistance Metal flange mount Flange pipe type Response time Temp. influence ■ Reverse polarity ■ Over-voltage Storage Temp. Probe head PC with glass fiber Operating Temp. & Humid. 0 ... 50°C / 20 ... 90%RH(Non-condensing) Fitting pressure Duct type Warm-up time Current consumption Signal connection Display & Operation(See manual for details) Display value 4 digits,...

Open the catalog to page 2
eyc-tech FTM06D Thermal Mass Flow Transmitter - 3

| Quality Calibration Equipment | ■Air velocity standard calibration system | Temperature Compensation Verification | Standard wind speed(m/s) Standard Temp.(°C) Wind velocity(m/s) Normal Temp. Standard wind speed

Open the catalog to page 3
eyc-tech FTM06D Thermal Mass Flow Transmitter - 4

Ø12mm PC+Glass filber Air velocity probe head Ø12mm PC+Glass filber Air velocity probe head ※Tube diameter selection DN15(1/2" G) / DN25(1" G) / DN40(1 1/

Open the catalog to page 4
eyc-tech FTM06D Thermal Mass Flow Transmitter - 5

■ Flange pipe type Connect the 2m cable Direction arrow Installation depth centered Air flow direction ※For detailed dimensions, please refer to manual-Flange Pipe | Ordering Guide | Medium Probe length N : Without display D : Display 1 : Duct type (Metal flange mount) 3 : Duct type (R1/2" movable thread) 4 : Flange pipe type (2″ ... 6″)(Customization) 5 : Inline type (1/2″ ... 2″)(Customization) Duct type 1 : 152 mm 2 : 202 mm 3 : 352 mm W : Customization

Open the catalog to page 5
eyc-tech FTM06D Thermal Mass Flow Transmitter - 6

| Air Velocity / Volume Conversion Table | ID of pipe Air velocity inside pipe | Additional Option Test Report | For more detailed information please contact us. ■ILAC / TAF YUDEN-TECH CO.,LTD. Calibration Laboratory - ( ILAC / TAF ) Test report. (TAF accreditation : 3032, complying with ISO / IEC 17025 ) TAF has mutual recognition arrangement with ILAC MRA Project Measurand level or range

Open the catalog to page 6