1. Catalogs
  2. YSI
  3. P 700 Orthophosphate Analyzer Specifications Sheet

P 700 Orthophosphate Analyzer Specifications Sheet

P 700 Orthophosphate Analyzer Specifications Sheet

P 700 Orthophosphate Analyzer Specifications Sheet

Product catalog summary
Overview: The YSI P 700 IQ Orthophosphate Analyzer is designed for measuring orthophosphate levels in wastewater treatment plants. It can function as a standalone unit or be integrated into the IQ SensorNet 2020 XT network, providing continuous data to enhance operational efficiency and verify phosphate elimination.
Key Features:
  • Compact design with an integrated pump for permeate supply.
  • Simple configuration with the IQ SensorNet for measuring additional parameters.
  • Low reagent consumption, requiring solution exchanges every 4-8 months.
  • Automatic or manual calibration and cleaning functions.
  • Utilizes the Vanadomolybdate (yellow) method for detection.
  • Available in indoor or outdoor versions with climate control options.
Technical Specifications:
  • Measurement Method: Vanadomolybdate (yellow).
  • Measurement Range: PO4-P Range A: 0.05 to 15.00 mg/L; Range B: 1 to 50 mg/L.
  • Resolution: PO4-P Range A: 0.01 mg/L; Range B: 1 mg/L.
  • Accuracy: ±2% or ±0.05 mg/L for Range A; ±2% or ±1 mg/L for Range B.
  • Response Time: T-90 < 5 minutes.
  • Operating Temperature: -20 to 40ºC for outdoor units; 15 to 40ºC for indoor units.
  • Reagent Consumption: 2500 mL for 8 months with Range A; 4 months with Range B.
  • Certifications: CE, IP54, UL.
Applications: Suitable for municipal and industrial wastewater treatment, including pre-sedimentation, aeration, post-sedimentation, and effluent stages.
Ordering Information: Various models are available for indoor and outdoor use, with options for filtration and climate control. Accessories such as mounting kits and standard solutions are also available.
See more

Catalog excerpts

P 700 Orthophosphate Analyzer Specifications Sheet-1

YSI P 700 IQ Orthophosphate Analyzer Orthophosphate Measurement for the IQ SensorNet System The P 700 for orthophosphate measurement can be used as a stand alone analyzer or networked with other sensors in an IQ SensorNet 2020 XT network. Use the P 700 throughout the wastewater plant from pre-sedimentation to biological tanks to the effluent. The P 700 provides continuous data to help operational efficiency improvement decisions and phosphate elimination verification. • Compact design - pump for permeate supply is integrated • Simple system configuration with the IQ SensorNet; measure additional parameters in addition to orthophosphate Wastewater treatment (municipal and industrial); presedimentation, aeration, post-sedimentation, effluent • Low reagent consumption - exchange solutions on average every 4-8 months, reduces overall cost vs. other analyzers • Automatic or manual calibration (adjustable) • Automatic cleaning function (adjustable) • Uses proven Vanadomolybdate (yellow) method of • Wide measuring range - two measuring ranges allow the The P 700 filter mounted inside a tank. Easy to clean with water and a brush, bleach, or hydrochloric acid. P 700 to be used in a wide range of locations throughout the WWTP • Indoor or outdoor versions available with heating or Technical Information for Filtration Membrane Surface Area Max. Operating Over Pressure (Raw water to permeate side): 2.0 bar at 68ºF (20ºC) Operating Under Pressure (permeate side) Housing: PVC; Seals: NBR; Screws: Stainless Steel

 Open the catalog to page 1
P 700 Orthophosphate Analyzer Specifications Sheet-2

P 700 IQ Technical Specifications Measurement Method Measurement Range PO4-P Resolution PO4-P Accuracy PO4-P Measurement Range PO4 Resolution PO4 Accuracy PO4 Response Time T-90 Detection Limit Calibration Dimensions Weight Measuring Interval Cleaning Solution Climate Control pH range Operating Temperature Storage Temperature Sample Temperature Reagent Consumption Equipment Safety, Standards Electrical Certifications Outputs Vanadomolybdate (yellow) Range A: 0.05 to 15.00 mg/L; Range B: 1 to 50 mg/L Range A: 0.01 mg/L; Range B: 1 mg/L Range A: ±2% or ±0.05 mg/L, whichever is greater; Range B:...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.