Aquaculture CONTINUOUS MONITORING AND CONTROL
16Pages

{{requestButtons}}

Catalog excerpts

Aquaculture CONTINUOUS MONITORING AND CONTROL - 1

Aquaculture CONTINUOUS MONITORING AND CONTROL

Open the catalog to page 1
Aquaculture CONTINUOUS MONITORING AND CONTROL - 2

Table of Contents 2-3 5200A Multiparameter Monitor Input Examples 7 Networking Thank you for considering YSI as your supplier of water quality monitoring and control instrumentation. As the demand for high quality aquaculture production increases and aquatic life support management becomes more automated, the need for water quality monitoring instrumentation to ensure a healthy harvest is also increasing. YSI, the manufacturer of handheld instruments you've used and trusted for years, is here to help. We have expanded our continuous water quality monitoring and control instrumentation...

Open the catalog to page 2
Aquaculture CONTINUOUS MONITORING AND CONTROL - 3

aquaculture Applications RAS (recirc systems) Raceways Ponds Cages Live Haul Aquariums Research Aquaponics Aquatic Life Support 5200A Aquatic Life Support Aquaponics Dissolved Oxygen (polarographic) pH Conductivity Temperature ORP Salinity TDS External devices* 5400 Dissolved Oxygen (galvanic) Temperature External devices* 5500D Dissolved Oxygen (optical) Temperature External devices* IOEM/REM Integrate other devices Expand outputs Add relays Send data to PLC or SCADA Monitors at a Glance Dependability. Monitoring and controlling with the 5200A, 5400, and 5500D is managed locally by the...

Open the catalog to page 3
Aquaculture CONTINUOUS MONITORING AND CONTROL - 4

Designed specifically for aquaculture and aquatic life support systems, the 5200A integrates water quality monitoring, process control, feeding, alarming, and data management into one instrument. Mulitparameter monitoring functionality for dissolved oxygen (DO), temperature, pH, ORP, conductivity, and automatic salinity compensation. Plus, two configurable inputs for additional sensors and management. Features • Ethernet TCP/IP or wireless communications - optional • Event logging records calibrations, high and low conditions, and more • Conditional feed timer with Feed Smart™ software...

Open the catalog to page 4
Aquaculture CONTINUOUS MONITORING AND CONTROL - 5

Parameters Dissolved Oxygen (polarographic) pH Conductivity Temperature ORP Salinity Additional user-configurable inputs* *User-configurable inputs can be used for additional sensors like DO, pH, TGP, ORP, level, pressure, etc. Some sensors require an additional transmitter. 5200A Specifications Conductivity Range: 0-200 ps, 0-2000 ps, 0-20 mS, 0-200 mS Resolution: 0.1 ps in 200 ps range; 1 ps in 2000 ps range; 0.01 mS in 20 mS range; 0.1 mS in 200 mS range Accuracy: ±0.5% of range (0-100 mS); ±1.0% of reading (100-200 mS) Dissolved Oxygen Description: Polarographic; automatic salinity...

Open the catalog to page 5
Aquaculture CONTINUOUS MONITORING AND CONTROL - 6

MultiDO Monitors Our continuous multi-channel dissolved oxygen (DO) monitoring and control instruments are designed specifically for aquaculture systems. Easily manage a full-scale farming operation with expandable capabilities. YSI 5400 The 5400 continuous monitor for dissolved oxygen (DO) with a galvanic sensor — along with AquaManager® software — integrates process control, feeding, alarming, and data management into one product. YSI 5500D The 5500D Optical DO (ODO) monitoring & control instrument continuously monitors your farming operation’s water quality for DO using optical-based ODO...

Open the catalog to page 6
Aquaculture CONTINUOUS MONITORING AND CONTROL - 7

Dissolved Oxygen Description 4 DO channels; Galvanic • 0.1 mg/L (10 to 60 mg/L) ±2% of reading or ±2% DO sat, whichever is greater (0 to 200%) • ±0.2 mg/L or ±2% of reading, whichever is greater (0 to 20 mg/L) ±6% of reading (200 to 500%; 20 to 60 mg/L) ±1% of reading or ±1% DO sat, whichever is greater (0 to 200%); • ±0.1 mg/L or ±1% of reading, whichever is greater (0 to 20 mg/L); ±10% of reading (200 to 500%) (20 to 50 mg/L) Salinity Input Range 0 to 50 ppt; manual (automatically compensates DO for manual input value) • • Description 4 timers - 10 cascading events with start/duration...

Open the catalog to page 7
Aquaculture CONTINUOUS MONITORING AND CONTROL - 8

Expansion Modules for Monitoring & Control Applications RAS Raceways Ponds Sea cages Live haul Aquariums Research Ensure healthy livestock and maximum profits with tighter control of water quality and system parameters. The YSI IOEM and REM expansion modules increase the flexibility and capability of the YSI aquaculture monitoring and control platform when networked with the 5200A, 5400 and/or 5500D instruments. IOEM Features • 4 (IOEM-4) or 8 (IOEM-8) user-configurable channels as inputs or outputs • Optically isolated to eliminate electrical interferences and ground loops • When...

Open the catalog to page 8
Aquaculture CONTINUOUS MONITORING AND CONTROL - 9

Example of multiple monitors individually controlling tanks integrated into the same network with various communications channels. Examples of Additional Inputs MJK pHix® pH or ORP and optional Temperature (with pH) sensor The compact, threaded design, makes pHix® very simple to mount in-line and in open tanks. The 2-wire 4-20 mA loop powered output easily connects to YSI's IOEM (Input Output Expansion Module). One-year warranty on the sensor and 6 months on the electrode. Features • Fully submersible • LED indicator light shows operation and calibration status • Available with 4-20 mA...

Open the catalog to page 9
Aquaculture CONTINUOUS MONITORING AND CONTROL - 10

Feed Smart™ (included) Conditional feed timer around the clock Feed Smart™ software can be used as a basic feed timer or conditional feed timer. Manages feed delivery based on user-selectable inputs for the number of daily feedings, daily feed weights, total biomass, and feed conversion ratios (FCRs) along with parameter control based on water quality values which reduces, or stops, feeding as water quality deteriorates. Outputs/Timers (included) 5400/5500D • 8 relays 10A at 110VAC (5A at 240VAC) • 4 timers - 10 cascading events with start/duration setting • 4 Feed Smart channels • Email...

Open the catalog to page 10
Aquaculture CONTINUOUS MONITORING AND CONTROL - 11

< TSI oMice Ifliiftinwnl Mapped Parameters pH: 8.54 Normal: Everyth mg ii good ORP.71 mV Norm.il: Everything i& gnn-d Temperature 1: 80.1 ftF N-aiiVi.-ih Evtiytfiing it-good Conductivity: SP ft.43 pS No rm.t I: Everything is-good DO 1: 6-9 mgf L Normal; Everything is good I Updated: 2 seconds ago KB Mnntlnring Made Mobi e Control Pumps, valves, feeders, alarms, lights, heaters, chillers, blowers, pure O2, ozone, etc. Monitor and control continuously Software Benefits The AquaViewer II app gives you real-time water quality data so you can keep a close eye on your facility, remotely. Data is...

Open the catalog to page 11

All YSI catalogs and technical brochures

  1. 2020 EXO

    7 Pages

  2. ODO RTU

    2 Pages

  3. ProDSS

    12 Pages

  4. WS705

    1 Pages

Archived catalogs

  1. 2014 EXO

    7 Pages