video corpo

YSI P 700 Orthophosphate Analyzer
2Pages

{{requestButtons}}

Catalog excerpts

YSI P 700 Orthophosphate Analyzer - 1

YSI P 700 IQ Orthophosphate Analyzer Orthophosphate Measurement for the IQ SensorNet System The P 700 for orthophosphate measurement can be used as a stand alone analyzer or networked with other sensors in an IQ SensorNet 2020 XT network. Use the P 700 throughout the wastewater plant from pre-sedimentation to biological tanks to the effluent. The P 700 provides continuous data to help operational efficiency improvement decisions and phosphate elimination verification. • Compact design - pump for permeate supply is integrated • Simple system configuration with the IQ SensorNet; measure additional parameters in addition to orthophosphate Wastewater treatment (municipal and industrial); presedimentation, aeration, post-sedimentation, effluent • Low reagent consumption - exchange solutions on average every 4-8 months, reduces overall cost vs. other analyzers • Automatic or manual calibration (adjustable) • Automatic cleaning function (adjustable) • Uses proven Vanadomolybdate (yellow) method of • Wide measuring range - two measuring ranges allow the The P 700 filter mounted inside a tank. Easy to clean with water and a brush, bleach, or hydrochloric acid. P 700 to be used in a wide range of locations throughout the WWTP • Indoor or outdoor versions available with heating or Technical Information for Filtration Membrane Surface Area Max. Operating Over Pressure (Raw water to permeate side): 2.0 bar at 68ºF (20ºC) Operating Under Pressure (permeate side) Housing: PVC; Seals: NBR; Screws: Stainless Steel

Open the catalog to page 1
YSI P 700 Orthophosphate Analyzer - 2

P 700 IQ Technical Specifications Measurement Method Measurement Range PO4-P Resolution PO4-P Accuracy PO4-P Measurement Range PO4 Resolution PO4 Accuracy PO4 Response Time T-90 Detection Limit Calibration Dimensions Weight Measuring Interval Cleaning Solution Climate Control pH range Operating Temperature Storage Temperature Sample Temperature Reagent Consumption Equipment Safety, Standards Electrical Certifications Outputs Vanadomolybdate (yellow) Range A: 0.05 to 15.00 mg/L; Range B: 1 to 50 mg/L Range A: 0.01 mg/L; Range B: 1 mg/L Range A: ±2% or ±0.05 mg/L, whichever is greater; Range...

Open the catalog to page 2

All YSI Life Science catalogs and technical brochures

  1. Colorimetry

    12 Pages

  2. Catalog 2012

    28 Pages

  3. YSI 7100

    4 Pages

Archived catalogs