YTA610
1 /20Pages

YTA610

YTA610
1 /20Pages

Catalog excerpts

YTA610-1

<<Contents>> <<Index>> General YTA610Specifications Temperatore TransmitterGS 01C50H01-01EN The YTA610 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a 4 to 20 mA DC or Fieldbus signal for transmission. The YTA610 supports HART and Foundation Fieldbus communication protocols. HART type is certified as complying with SIL 2 for safety requirement. ■ FEATURES High reliability Dual-compartment housing realizes high resistance capability to harsh environments. Variety of sensor inputs The type of sensor input is user-selectable from thermocouples (T/C), RTDs, ohms, or DC millivolts. Digital communication HART protocol revision is 7 and Foundation Fieldbus. The instrument configuration can be changed by the user with using the Fieldmate or Handheld terminal. Local Parameter Setting Parameter configuration by the push button offers easy and quick setup for parameters. Self-diagnostics function Continuous self-diagnostics capability ensures longterm performance and lower cost of ownership. Dual universal inputs Dual input can accept two thermocouple, RTD, ohm or DC millivolt inputs. Differential or average temperature measurement is selectable. The sensor backup function for automatically switches-over from the primary to the backup upon sensor failure. ■ STANDARD SPECIFICATIONS ■ PERFORMANCE SPECIFICATIONS Accuracy HART communication type: A/D accuracy/span + D/A accuracy (See Table 1 on page 4.) Fieldbus communication type: A/D accuracy (See Table 1 on page 4.) Cold Junction Compensation Accuracy ± 0.5°C (± 0.9 °F) for T/C only Ambient Temperature Effect (per 10°C change) See Table 2 on page 5. Stability (at 23±2°C) RTD: ±0.1% of reading or ±0.1°C per 2 years, whichever is greater. T/C: ±0.1% of reading or ±0.1°C per year, whichever is greater. 5 Year Stability (at 23±2°C) RTD: ±0.25% of reading or ±0.25°C, whichever is greater. T/C: ±0.5% of reading or ±0.5°C, whichever is greater. Vibration Effect The YTA610 is tested to the following specifications with no effect on performance per IEC 60770-1 10 to 60 Hz : 0.21 mm peak displacement 60 to 2000 Hz : 3G Power Supply Effect (HART type) ±0.005% of calibrated span per volt Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5690 Fax.: 81-422-52-

 Open the catalog to page 1
YTA610-2

■ FUNCTIONAL SPECIFICATIONS Input Signals Input number: single and dual input Input type is selectable: Thermocouples, 2-, 3-, and 4-wire RTDs, ohms and DC millivolts. See Table 1. on page 4. Input Signal Source Resistance (for T/C, mV) 1 kQ or lower Input Lead Wire Resistance (for RTD, ohm) 10 Q per wire or lower Span & Range Limits See Table 1. on page 4. Output Signals Two wire 4 to 20 mA DC type Output range: 3.68 to 20.8 mA DC HART protocol is superimposed on the 4 to 20 mA signal. Fieldbus type Output signal based on Foundation Fieldbus communication protocol. Isolation Input/Output/GND...

 Open the catalog to page 2
YTA610-3

Safety Requirement Standards EN61010-1, C22.2 No.61010-1 • Installation category: I (Anticipated transient overvoltage 330 V) • Pollution degree: 2 • Indoor/Outdoor use EN61010-2-030, C22.2 No.61010-2-030 • Measurement category: O (Other) (Measurement Input voltage: 150mVdc max) EU RoHS Directive Applicable standard: EN 50581 ■ NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits –40 to 85°C (–40 to 185°F) –30 to 80°C (–22 to 176°F) (with indicator model) Ambient Humidity Limits 0 to 100% RH at 40°C (104°F) Supply Voltage Requirements...

 Open the catalog to page 3
YTA610-4

Table 1. Sensor type, measurement range, and accuracy Note 1: Total Accuracy = (A/D Accuracy / Span + D/A Accuracy) or (± 0.1% of calibrated span), whichever is greater. Accuracy of Fieldbus type: A/D Accuracy. For T/C input, add Cold Junction Compensation Error (± 0.5°C) to the total accuracy. Example: when selecting Pt100 with measurement range of 0 to 400 °C 0.14°C / 400°C*100% of span +0.03% of span = 0.065% of span Since the value is smaller than ±0.1% of span, the total accuracy is ±0.1%. Note 2: T/C C type is same as W5 (ASTM E988). All Rights Reserved. Copyright © 20

 Open the catalog to page 4
YTA610-5

Table 2. Temperature coefficient *1: For flat-panel mounting, please prepare bolts and nuts. All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Jul

 Open the catalog to page 5
YTA610-6

Note: The indication of the nameplate shows an initial shipment state. *1: Not applicable for Stainless housing. *2: Not applicable for Fieldbus type. *3: Except for Amplifier and terminal cover, color and coating are general specification. *4: Lightning protector (surge absorber) can be remove from, or added to the equipment. *5: Combination with other Explosion protected other than TIIS flameproof is not possible. *7: Applicable for Electrical Connection code 4. (The thread of connection between YTA and CABLE GLAND is M20, and the thread of connection between CABLE GLAND and CABLE is G1/2.)...

 Open the catalog to page 6
YTA610-7

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 7
YTA610-8

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 8
YTA610-9

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 9
YTA610-10

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 10
YTA610-11

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 11
YTA610-12

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 12
YTA610-13

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 13
YTA610-14

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C50H01-01EN Mar. 04, 2021-00

 Open the catalog to page 14

All YOKOGAWA Europe catalogs and technical brochures

  1. YS1500

    20  Pages

  2. UM33A/S006

    2  Pages

  3. FA-M3V

    19  Pages

  4. RAMC

    24  Pages

  5. TB750G EXAxt

    3  Pages

  6. OX400

    2  Pages

  7. MW100

    5  Pages

  8. FieldMate

    5  Pages

  9. AMADAS

    4  Pages

  10. Exapilot

    5  Pages

  11. Exaquantum

    5  Pages

  12. BUCA150_E_050

    4  Pages

  13. BUAQ7280-01

    12  Pages

  14. BUXL120_E_030

    8  Pages

  15. BU7603_00E_060

    20  Pages

  16. BUAQ2200

    8  Pages

  17. Batch Control

    9  Pages

  18. ADMAG Series

    9  Pages

  19. Exaplog

    2  Pages

  20. AAASuite

    2  Pages

  21. InfoWell

    8  Pages

  22. VTSPortal

    2  Pages

  23. U33Q01A01-01E

    11  Pages

  24. BU33K01A01-50E

    11  Pages

  25. CENTUM.VP

    11  Pages

  26. ADMAG AXF

    2  Pages

  27. YTA series

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.