Co-innovating tomorrow™ SMARTDAC+ Data Acquisition & Control Data Acquisition System GM
Open the catalog to page 1Data Acquisition & Control Your business environment is complex and rapidly changing. You need smart and powerful systems that can adapt to your process. is a fresh approach to data acquisition and control, with smart and simple touch operation as a design priority. Measure, display and record process data with greater levels of clarity, intelligence and accessibility. The concept started with the GX/GP, an integrated I/O and recording system with a familiar touch operator interface. Building upon the the highly adaptable, scalable and easy to operate GM data logger. Precise, Reliable & Adaptable...
Open the catalog to page 2■ 600V high withstand voltage (GX90XA-10-V1 High Withstand Voltage AI Module) ■ PID control (GX90UT PID Control Module) ■ Program control (/PG option) ■ Dual interval measurement ■ High speed (1 ms) measurement (GX90XA-04-H0 High Speed AI Module) ■ 4-wire RTD input, resistance measurement (GX90XA-06-R1 4-Wire RTD Module) ■ Retransmission/manual mA output (GX90YA Analog Output Module) Ready for the future when you are Smart Architecture Navigate with ease Smart User Interface Data analysis made simple and mobile Smart Functionality Data Acquisition
Open the catalog to page 3Ready for the future when you are Smart Architecture Increase channels by adding additional block modules YOKOGAWA proprietary block architecture [Patent technology] ●Expand one, or multiple module at a time ●Unique design houses modules in linked module bases ●Module base ensures linkage (slide locks and mounting screws also available) ●Modules can be inserted and removed from the front panel for easy maintenance 2 ways of linking: slide lock and screw Slide lock Module Base Link Power switch Input/output Module Data Acquisition Module Power Supply Module Inlet. For screw terminals, acts as...
Open the catalog to page 4Select modules according to your application. Noise-resistant, magnetic relay types also available. All modules have removable terminal blocks for easy wiring. The same modules used in the SMARTDAC+ series. Internal memory and max. I/O channels Type Type Internal memory * When analog input only Actual values support high precision measurement Input type The measuring accuracies noted in the general specifications on page 15 have a margin of error that takes into account the product's components and the equipment used for adjustment and testing. However, the actual values calculated from the accuracy...
Open the catalog to page 5Navigate with ease Smart User Interface Easy access from a Web browser Through a Web browser you can monitor the GM in real time and change settings. You can easily build a seamless, low-cost remote monitoring system with no additional software. Real time monitoring screen With the scroll bar, you can seamlessly scroll between past and current trends. Enter settings online with a web browser The setting screen lets you copy AI channel settings and other information to Excel for editing. You can reimport the data into the setting screen after editing. Trend, digital, and other real-time displays...
Open the catalog to page 6Dedicated software (free download) is available for loading waveforms and GM settings Universal viewer Offline setting software Data files saved on the GM can be viewed and printed. You can perform statistical computation over an area and export to ASCII, Excel, or other formats. Save settings or transfer them to the GM. Connections can also be made easily via USB or Bluetooth. USB comes standard (USB communication function) Send/receive settings Ethernet Data converted to an ASCII file Load/save settings Safe to use in a wide range of temperatures With operating temperatures of -20°C–60°C, it...
Open the catalog to page 7High speed measurement (down to 1 ms) Yokogawa's proprietary A/D converter allows the high speed module to measure data points as fast 1ms. • High speed (1 ms) measurement* • Proprietary A/D converter * With 1 ch per module. At 2 ms, 2 ch per module, and at 5 ms or more, all 4 ch per module. Max. channels Users have the ability to choose two different scan intervals on a single GM system. This allows users the flexibility to measure various types of inputs with two different scan intervals in a single system. For example, this provides for efficient, simultaneous measurement of signals with slow...
Open the catalog to page 8PID control function Control function Enables PID and program control ●PID control module 2-loops per module, up to 20 loops per system ●Setpoint program control function (/PG option) Up to 99 patterns Proprietary A/D GX90UT PID control module Remote operation and monitoring The web application enables remote operation and monitoring from a browser. With the Web Server function, simply access the GM from a web browser on a PC for easy operation and monitoring of control loops. Application examples Utility equipment Industrial furnace ● Ideal for centralized control of multiple loops ● Modular...
Open the catalog to page 9Aerospace Heat Treatment Supports heat treatment application AMS2750/NADCAP Calibration correction schedule control function (/AH option) Schedule management for periodically executing calibration correction configuration and the like. You can set the input correction factor as a sensor correction factor and instrument correction factor. TUS software is available for easily creating TUS (temperature uniformity survey) reports. * For details on TUS software, consult with your Yokogawa dealer. Input calibration is performed in the AI channel setting screen, and the calibration period settings are...
Open the catalog to page 10Provides a variety of convenient networking functions Networking Modbus/TCP and Modbus/RTU Communications GM supports Modbus TCP/IP client and server modes for Ethernet communications and Modbus RTU master and slave modes for optional serial communications. Modbus/TCP (Ethernet connection), Modbus/RTU (RS-422/485 connection) Modbus client/Modbus master Modbus server/Modbus slave Using the Modbus/TCP and Modbus/RTU functions, you can display and save data from the server and slave devices on the GM. * Requires the communication channel (/MC option). Upstream device Using the Modbus/TCP and Modbus/RTU...
Open the catalog to page 1120 Pages
2 Pages
20 Pages
19 Pages
24 Pages
12 Pages
135 Pages
3 Pages
2 Pages
3 Pages
8 Pages
4 Pages
7 Pages
8 Pages
2 Pages
4 Pages
4 Pages
17 Pages
5 Pages
5 Pages
4 Pages
5 Pages
5 Pages
4 Pages
12 Pages
8 Pages
20 Pages
8 Pages
8 Pages
3 Pages
3 Pages
7 Pages
9 Pages
5 Pages
9 Pages
2 Pages
2 Pages
86 Pages
3 Pages
10 Pages
2 Pages
2 Pages
2 Pages
9 Pages
2 Pages
2 Pages
8 Pages
3 Pages
3 Pages
2 Pages
4 Pages
2 Pages
11 Pages
11 Pages
8 Pages
27 Pages
26 Pages
12 Pages
3 Pages
4 Pages
11 Pages
5 Pages
2 Pages
7 Pages
28 Pages
12 Pages
19 Pages
14 Pages