Catalog excerpts

Limiting-current type Oxygen Analyzer OX100, OX102 OX100, OX102 Limiting-current type Oxygen Analyzer • One Instrument measures 100 ppm to 25% Oxygen • Simple "One Touch" Calibration • Self Diagnostics Assure High Reliability • "One Touch" Sensor Replacement • Compact Size • Accessories to Assure Accuracy • Dedicated Sampling Unit (Separate from Oxygen Analyzer) (Removes Dust, Mist and Organic Solvents) • Calibration Kit Simple On-Site Calibration (Using 1 liter Gas Cylinder)
Open the catalog to page 1
A Compact Environmental Oxygen Anal] Enhanced Oxygen Analyzer • Autoranging in four ranges from 0-100 ppm to 0-25% 1N2 reflow furnaces ■Semiconductor maker environmental monitoring ■ppm-level O2 measurement ■ Monitoring purity of N2, Ar separated from air ■ Monitoring for deficiency of O2 •FAIL lamp Alarm lamps (Calibration keys I— ©Lit when range parameter entry • Plastic sensor holder (Specify Option code /J (Sensor plus cable: *5 m (OX100), *5,10 or 30 m (OX102) 1 : When mount in 17 mm hole in panel, panel thickness can be up to 4 mm. 2 : Within 5 cm of sensor tip, can reach 250°C. 3 :...
Open the catalog to page 2
Panel thickness * : Allow the minimum clearance of Min. space for multiple installation : A Ma* temp. 1 StFC when metal nipple {option code 73* or P/W K9424DB) is used. Extension cable Sensor Assembly
Open the catalog to page 3
OX102 EXTERNAL DIMENSIONS Convertor Other instrument * : Allow a minimum distance of 115mm for ease of removal. Min. space for multiple installation Sensor parameter Table Sensor NO. XXXX Temp. 150ЊC Max. Temp. 250ЊC Max. ءMax temp. 70ЊC when plastic nipple (option code "/J" or P/N L9811LA) is used. Sensor External Dimension Model Code
Open the catalog to page 4
Pressure meter (flow adjustment) Sampling unit (K9424GA) Power supply 1 Activated charcoal, membrane filter Flow meter 1000 ppm O2/N2 Quantity 6, one-liter Calibration gas cylinder (K9424JP) Needle valve Membrane filter: removes dust / mist / flux Activated charcoal, membrane filter: remove organic solvents Flow meter: 0.1 to 1 liters / min. Operating conditions: Atmospheric pressure, gas temperature 0 to 40°C Mounting Rc 1/4 Power 100-240 V AC Calibration kit (K9424JA, JB) Gas outlet cock + Qty. 6, one Calibration gas cylinder 210 x 75 x 335 mm, approx 800 g. Power line connector Sample...
Open the catalog to page 5
OX102 Standard Specifications Model Meas. principle Sampling Sample gas condition Measured gas Mounting Meas. ranges Repeatability Limiting-current type Natural diffusion Temperature 0 - 70°C, Humidity 0 - 80% RH (dew free), Pressure 1013 ± 40 hPa (Abs) O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases or organic solvents Indoor, panel mounting 0-100 ppm / 0-1000 ppm / 0-10000 ppm / 0-25%, automatic / fixed switching mode ±15 ppm (Meas. range : 20-100 ppm), ±25 ppm (Meas. range : 100-1000 ppm), ±0.3%of reading (Meas. range : 1000-5000 ppm), ±7.5% of reading...
Open the catalog to page 6
I 0X102 Limiting-current type Oxygen Analyzer VigilantPlant is Yokogawa's automation concept for safe, reliable, and profitable plant operations. VigilantPlant aims to enable an ongoing state of Operational Excellence where plant personnel are watchful and attentive, well-informed, and ready to take actions that optimize plant and business performance. YOKOGAWA ELECTRIC CORPORATION World Headquarters North America YOKOGAWA CORPORATION OF AMERICA South America YOKOGAWA AMERICA DO SUL LTDA. European Headquarters RUSSIAN FEDERATION Middle East YOKOGAWA MIDDLE EAST B.S.C.(C) YOKOGAWA...
Open the catalog to page 7All YOKOGAWA Europe catalogs and technical brochures
-
YS1500
20 Pages
-
UM33A/S006
2 Pages
-
YTA610
20 Pages
-
FA-M3V
19 Pages
-
RAMC
24 Pages
-
GS610 Source Measure Unit
12 Pages
-
EJXC40A Digital Remote Sensor
135 Pages
-
TB750G EXAxt
3 Pages
-
VPSRemote Remote Solution
2 Pages
-
SENCOM Degital Sensor
3 Pages
-
Product Solution Catalog
8 Pages
-
Data Logging Software GA10
4 Pages
-
JUXTA VJ series
7 Pages
-
µR10000/µR20000
8 Pages
-
OX400
2 Pages
-
PR300 Power and Energy Meter
4 Pages
-
CENTUM RIO System Upgrade
4 Pages
-
Autonomous Controller FCN-RTU
17 Pages
-
MW100
5 Pages
-
FieldMate
5 Pages
-
AMADAS
4 Pages
-
Exapilot
5 Pages
-
Exaquantum
5 Pages
-
BUCA150_E_050
4 Pages
-
BUAQ7280-01
12 Pages
-
BUXL120_E_030
8 Pages
-
BU7603_00E_060
20 Pages
-
BUAQ2200
8 Pages
-
NR800 Near Infrared Analyzer
8 Pages
-
GD402 Gas Density Analyzer
3 Pages
-
DT450G Dust Monitor
3 Pages
-
SCADA Software VDS
7 Pages
-
Batch Control
9 Pages
-
FieldMate catalogs
5 Pages
-
DPharp for The Digital World
9 Pages
-
RAGN Rotameter
2 Pages
-
HART Communicator YHC5150X
2 Pages
-
Catalog_YMI130_EN
86 Pages
-
Bulletin11G04G01-01E
3 Pages
-
Bulletin11B03A03-01E
10 Pages
-
FY01A08A08-E-E
2 Pages
-
Ultrasonic Flowmeter US300FM
2 Pages
-
AXF Verification Tool
2 Pages
-
ADMAG Series
9 Pages
-
Exaplog
2 Pages
-
AAASuite
2 Pages
-
InfoWell
8 Pages
-
Low Power Controller FCN-RTU
3 Pages
-
Standalone SIS
3 Pages
-
VTSPortal
2 Pages
-
CENTUM VP - CAMS for HIS
4 Pages
-
GS01E06K02-00E
2 Pages
-
U33Q01A01-01E
11 Pages
-
BU33K01A01-50E
11 Pages
-
Thermometers Catalog
8 Pages
-
PH400G 4-Wire Type pH Meter
27 Pages
-
SG750 Stack Gas Analyzers
26 Pages
-
Clamp-on Testers
12 Pages
-
Dust Monitor DT450G
3 Pages
-
Handy Calibrators
4 Pages
-
CENTUM.VP
11 Pages
-
Fieldbus Segment Indicator
5 Pages
-
ADMAG AXF
2 Pages
-
YTA series
7 Pages
-
TEST & mEASUREmENT 2011
28 Pages
-
digital multimeter series
12 Pages
-
WT 3000 Precision Power Analyzer
19 Pages
-
DL850/DL850V SCOPECORDER
14 Pages