General Overview: The GC1000 Mark II is a process gas chromatograph by Yokogawa Electric Corporation, designed for precise analysis of gas or volatile liquid samples. It is known for its reliability and accuracy across various industries.
Features:
  • High Resolution Analysis: Utilizes high-resolution capillary columns for PIONA and distillation point analysis.
  • Wide Boiling Point Range: Analyzes samples with diverse boiling points using a thermostatic oven with precise temperature control.
  • User-Friendly Operation: Features a user-friendly display and keyboard for easy operation and data access.
  • Remote Maintenance: Supports remote operation via PC software for enhanced maintenance.
  • High Sensitivity Detection: Employs a high sensitivity TCD detector, eliminating the need for fuel gas and flame.
Applications: Suitable for petrochemistry, petroleum refining, chemical industries, electric power/gas, iron and steel, air plants, and environmental monitoring.
Wiring and Piping: Includes detailed diagrams and specifications for wiring and piping, emphasizing proper installation and grounding for safety and functionality.
Standard Specifications:
  • Measurable Objects: Gas or liquid samples.
  • Detection Methods: TCD, FID, FPD with ranges from 1ppm to 100%.
  • Components and Streams: Measures up to 255 components across 31 streams.
  • Temperature Control: Features isothermal and programmed temperature ovens with precise PID control.
  • Utility Requirements: Specifies power supply, instrument air, and carrier gas requirements.
Input and Output Signals: Details analog and contact input/output specifications, including communication protocols for DCS integration.
Specifications: Covers communication protocols and explosion protection for GC8 and GC1000 types, including settings for start/stop bits, parity, ASCII7 bit, and selectable speeds. An RS-422/RS-232C converter is provided for explosion protection.
Transmission and Reception: Transmission includes analysis results, calibration coefficients, and alarms, while reception involves operation requests. The PC communication standard is RS-422 with speeds of 19.2/38.4 kbps.
Analyzer Bus: Standard is Ethernet 100BaseTX or 100BaseFX. For explosion protection, the twisted pair line should be disconnected when not maintaining explosion-proof status.
External Dimensions: Provides detailed dimensions and installation notes for various configurations, including explosion-proof models.
Recommended Cables: Details on wiring connections, cable types, and protection systems, emphasizing shielding and grounding requirements.
Analyzer Base Sampling System: Emphasizes selecting an appropriate sampling system based on sample properties, with guidelines for sample conditioning, suction, and heating systems.
External Sampling System: Allows for up to 31 automatic stream switches, driven by a 350kPa pneumatic signal.
Flow Selection Diagrams:
  • Gas Sampling: Includes multipoint measurement and sample return options with specific pressure requirements.
  • Liquid Sampling: Utilizes a liquid sampling valve with a vaporizer for samples with a boiling point of 270°C or less.
Sample Flow Diagram: Describes components like flame arresters, pressure gauges, and solenoid valves, with specified maximum flow rates.
Standard Sampling System:
  • Sample Inlet System: Configurations for manual, automatic, and remote operations.
  • Sample Outlet System: Options for ejector suction and atmospheric balancing.
  • Sample Heating System: Details on steam tracing and thermal sensing for vaporized liquid samples.
  • Standard Gas Inlet System: Options for manual and automatic operations.
Ordering Specifications for GC1000 Series Analyzer: Includes installation conditions, utilities, explosion protection specifications, and communication options.
Process Condition and Measuring Range: Requires detailed information on stream names, concentrations, measuring ranges, and process conditions.
See more

Catalog excerpts

GC1000 Mark II Process Gas Chromatographs  -1

General Specifications Model GC1000 Mark II Process Gas Chromatograph A Gas Chromatograph analyzes a gas or volatile liquid sample by separating components for detection. The discrete separation and positive identification of components and measurement of the composition with no interference is a positive advantage of the gas chromatograph. Making good use of this advantage, the process gas chromatograph is widely used in many industries. YOKOGAWA manufactures two models of GC1000 Process Gas Chromatographs: the GC1000E/C/ S (isothermal oven type) and the GC1000T/W/D (programmed temperature type). The GC1000E/ C/S can analyze gas and liquid samples from room temperature up to elevated temperatures corresponding to their boiling points. The GC1000T/ W/D is capable of performing high resolution analysis by using capillary columns similar to laboratory gas chromatograph. n Capabilities of analyzing PIONA and the Distillation points Techniques for laboratory analyses can also be utilized in the GC1000 series by configuring and installation of high resolution capillary columns. This allows for the analysis of properties such as PIONA and Distillation points. n Capability of analyzing high boiling point liquid samples The liquid sampling valve with vaporizer having a tight seal provides highly accurate liquid sampling. The liquid sample is vaporized by an internal heater and introduced to the columns. This allows for highly consistent sample volume and excellent reproducibility. n Capability of analyzing samples in a very wide range of boiling points In the thermostatic oven, temperature is accurately controlled within +/- 0.03°C by an air-bath and circulation fan. For wide boiling point range samples, the programmed temperature oven enables the GC1000 to analyze these samples with high resolution. n Easy operation via User Friendly Displays User friendly keyboard and display allows easy operation and display of analysis data. Many functions can easily be accessed to the user including auto gate tracking, column end-of-life warning and auto gain setting. n Enhanced maintenance using PC operation With our maintenance terminal software (GCMT/ ASMT), the GC1000 can be operated from remote location like the control room or office. In addition, the analyzer bus allows for total maintenance management system to include other field analyzers and data acquisition capabilities. n Achievement of High Sensitivity TCD Most analysis which normally requires FID detector can now be done using the new high sensitivity TCD detector. This eliminates the requirement of fuel gas and presence of flame as in the FID. n Expectation of the effective result by EPC EPC (Electronic Pressure Control) controls the utility gas pressure by electronics and software, providing the same efficiency as programmed temperature analysis. Examples of Applications in Industries The GC1000 can be used for monitoring and quality control in following industries and applications. l Petrochemistry: Ethylene, Poly-propylene, Polyethylene, BTX, Butadiene, Vinyl chloride, Styrene, Alcohol, Aldehyde, Ester, and Vinyl acetate l Petroleum refinery: Distillation point analysis, PNA/ PINA analysis, FCC, Sulfur Recovery l Chemistry: Silicone, Chlorides, Fluorine compounds, Formalin, methanol, Urea, Ammonia, Phenol l Electric power/gas: Fuel gas, Exhaust gases, Coal gasification/liquefaction, Fuel cell l Iron and steel: Blast furnace, Coke oven l Air plant: Inorganic gas analyses l Chemicals: Chemicals, Agricultural Chemicals l Environmental monitoring: Air pollution observation, Plant/Work environmental analyses The GC1000 can, of course, respond to many other applications. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792

 Open the catalog to page 1
GC1000 Mark II Process Gas Chromatographs  -2

n WIRING AND PIPING DIAGRAM (1) Using Vent Stack (Note 9) Independent grounding (100Ω or less) (Note 8) Communlcation via personal computer Transmission: Analysis results, Operation info., Operational conditions Reception: Operation requests, Operational conditions change RS-422, 19.2/38.4k bps; for explosion protection, an RS-422/RS-232C converter is provided. Communication via DCS Transmission : Analysis results Reception : Operation requests RS-422 1200/2400/4800/ 9600/19200bps for explosion protection, an RS-422/RS-232C converter is provided. Analog input (4 to 20mA DC/1 to 5V DC) 4 points...

 Open the catalog to page 2
GC1000 Mark II Process Gas Chromatographs  -3

Using No Vent Stack (Note 7) Independent grounding (100Ω or less) (Note 6) Communlcation via personal computer Transmission: Analysis results, Operation info., Operational conditions Reception: Operation requests, Operational conditions change RS-422, 19.2/38.4k bps; for explosion protection, an RS-422/RS-232C converter is provided. Communication via DCS Transmission : Analysis results Reception (Note 4) : Operation requests RS-422 1200/2400/4800/ 9600/19200bps for explosion protection, an RS-422/RS-232C converter is provided. Analog input (4 to 20mA DC/1 to 5V DC) 4 points Contact input (5V...

 Open the catalog to page 3
GC1000 Mark II Process Gas Chromatographs  -4

Measurable object: Gas or liquid Measurement principle: Component separation·····by elution Detection··························TCD, FID, FPD Measurable ranges: TCD················1ppm to 100% · FID··················1ppm to 100% FPD· ···············1ppm to 0.1% · Number of streams to be measured: Maximum of 31 (including standard sample) Number of components to be measured: Maximum of 255 Analysis period: aximum of 99999.9 sec. M Quantifying method: Absolute calibration Sensitivity-corrected absolute calibration Corrected area normalization Material of the sample-contact parts: Stainless steel...

 Open the catalog to page 4

All YOKOGAWA Europe catalogs and technical brochures

  1. YS1500

    20  Pages

  2. UM33A/S006

    2  Pages

  3. YTA610

    20  Pages

  4. FA-M3V

    19  Pages

  5. RAMC

    24  Pages

  6. TB750G EXAxt

    3  Pages

  7. OX400

    2  Pages

  8. MW100

    5  Pages

  9. FieldMate

    5  Pages

  10. AMADAS

    4  Pages

  11. Exapilot

    5  Pages

  12. Exaquantum

    5  Pages

  13. BUCA150_E_050

    4  Pages

  14. BUAQ7280-01

    12  Pages

  15. BUXL120_E_030

    8  Pages

  16. BU7603_00E_060

    20  Pages

  17. BUAQ2200

    8  Pages

  18. Batch Control

    9  Pages

  19. ADMAG Series

    9  Pages

  20. Exaplog

    2  Pages

  21. AAASuite

    2  Pages

  22. InfoWell

    8  Pages

  23. VTSPortal

    2  Pages

  24. U33Q01A01-01E

    11  Pages

  25. BU33K01A01-50E

    11  Pages

  26. CENTUM.VP

    11  Pages

  27. ADMAG AXF

    2  Pages

  28. YTA series

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.