1. Catalogs
  2. YOKOGAWA Europe
  3. EJXC40A Digital Remote Sensor

EJXC40A Digital Remote Sensor

EJXC40A Digital Remote Sensor
1 / 135 PagesView full catalog

EJXC40A Digital Remote Sensor

Product catalog summary
Overview: The document provides comprehensive specifications and applications for Yokogawa Electric Corporation's Diaphragm Seal Systems. These systems are designed to measure parameters such as flow, level, density, and pressure of liquids, gases, or steam, while preventing the process medium from entering the pressure-sensing assembly of transmitters.
Applications: These systems are suitable for handling high/low temperature fluids, corrosive or viscous fluids, fluids prone to clogging, toxic fluids, and those with suspended solids.
Communication Types: The document mentions communication types like FOUNDATION Fieldbus and PROFIBUS PA, with specific GS numbers for each.
Diaphragm Seal System Types: Various types are outlined, including Inner Diaphragm Type, Direct Mounted, Digital Remote Sensor, Hygienic, and Absolute Pressure Diaphragm Seal Systems.
Features: Emphasizes high performance, accuracy, and reliability, with capabilities for high temperature and vacuum use, fast response times, and segment signal characterization.
Compensating Capillary Design: This design balances the volume and temperature of fill fluids, reducing ambient temperature influence.
Product Specifications: Detailed specifications include process connection sizes and applicable transmitter models.
Span and Range Limits: Tables detail measurement span and range limits for different systems, categorized by pressure type and connection style.
Remote Mount Flanged Diaphragm Seal Specifications: Includes temperature range, seal system location, seal fill fluid options, transmitter connection type, capillary length and diameter, process connection size, sealing face, diaphragm material, flange standards, and pressure ratings.
Material Considerations: Users must consider wetted parts material characteristics and process fluid influence to prevent leakage and contamination.
Process and Ambient Temperature: Specifications for silicone oil, fluorinated oil, and ethylene glycol are provided, detailing their temperature ranges.
Installation Note: Differential pressure transmitters should be installed at least 600 mm below the high-pressure process connection, with variations based on conditions.
Specifications: Details on isolating diaphragms, process and ambient temperatures, working pressures, and specific gravity for various fill fluids are provided.
Procedures: Installation guidelines emphasize the importance of proper installation based on ambient temperature, operating pressure, fill fluid, or diaphragm material.
Norms and Standards: References standards like NACE MR0175 (2003) for material recommendations.
Recommendations: Users should consider wetted parts materials and process fluids, especially for corrosive fluids. Contact with Yokogawa is recommended for detailed material information.
Key Data from Tables: Tables provide information on diaphragm materials, sealing face materials, and capillary specifications.
Critical Information: Selecting the correct fill fluid and diaphragm material is crucial for safety and contamination prevention.
Material Specifications and Recommendations: Emphasizes selecting appropriate materials for wetted parts to prevent contamination and damage, with recommendations for materials like Hastelloy C-276 and 316 SST.
Temperature and Pressure Specifications: Detailed specifications for process and ambient temperatures, working pressures, and specific gravity for different fluids are provided.
Diaphragm Seal Systems: Describes various models and configurations, including direct mount hygienic diaphragm seals and flushing connection rings.
Optional Specifications: Includes features like operating temperature correction and pressure/leak test certificates.
Key Tables and Figures: Tables provide critical data on material compatibility, temperature and pressure limits, and optional specifications.
Flange Specifications: Outlines specifications for different flange sizes and standards, including dimensions and bolt hole details.
Diaphragm Seal Types: Describes various types, including remote mount hygienic diaphragm seals and direct mount flanged diaphragm seals.
Extended Length Options: Provides options for extended lengths with specific codes.
Applicable Products: Lists applicable products, including differential pressure transmitters and their compatible diaphragm seal systems.
Key Considerations: Emphasizes selecting the correct flange and diaphragm seal configurations based on application requirements.
Ordering Information: Outlines the process for ordering, including model, suffix codes, option codes, calibration range, units, output mode, display scale, and tag number.
Software Tag Configuration: Specifies characters for 'Tag' and 'Long tag' in the amplifier memory.
Factory Configurations: Option code CA allows further configuration at the factory, including descriptor, message, and software damping settings.
Material Cross Reference: Cross-references ASTM grades with JIS grades.
See more

Catalog excerpts

EJXC40A Digital Remote Sensor-1

<<Contents>> <<Index>> DPharpEJpt DP harp EJfir [Diaphragm Seal System] Diaphragm Seal System can be used to measure liquid, gas, or steam flow as well as liquid level, density, and pressure. Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of the differential or Gauge pressure transmitter. Application which is suitable for diaphragm seal system For measuring the flow of ; • high/lowtemperature fluids • highly corrosive/high viscosity fluids • the fluids which may cause clogging of impulse piping in the low temperature • toxic fluids • the fluids containing suspended solids which are deposited in the impulse piping and may cause clogging. Venting/draining can be operated by installing the flushing connection ring, Adapter connection type Flange connection type Diaphragm Seal System (Inner Diaphragm type) Refer to GS as of the table below for Fieldbus communication type and PROFIBUS PA communication type for the items marked with “0.” Direct Mounted Diaphragm Seal System The codes of diaphragm seal system represent a seal system type. CE and other standard certification are acquired for each transmitter section. Diaphragm Seal System YOKOGAWA ♦ Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5690 Fax.: 81-422-52-2018

 Open the catalog to page 1
EJXC40A Digital Remote Sensor-2

• Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or differential pressure transmitter with one or two diaphragm seal. Suitable for various kinds of pressure measurement. Diaphragm Seal System Applicable Products (Transmitter)*1 • Differential Pressure Transmitter EJX110A: GS01C25B01-01EN EJA110E: GS01C31B01-01EN • Gauge Pressure Transmitter EJX430A: GS01C25E01-01EN EJA430E: GS01C31E01-01EN Process connection size • Flush Flanged Seal 1 1/2-inch (40 mm), 2-inch (50 mm), 3-inch (80 mm) • Extended Flanged Seal 3-inch (80 mm), 4-inch (100 mm) • Inner Diaphragm Seal, Adapter...

 Open the catalog to page 2
EJXC40A Digital Remote Sensor-3

• Absolute Pressure Diaphragm Seal System Diaphragm Seal System consists of absolute pressure transmitter with a single diaphragm seal. Suitable for various kinds of pressure measurement. Applicable Products (Transmitter)11 • Absolute Pressure Transmitter EJX310A: GS01C25D01-01EN EJA310E: GS01C31D01-01EN Process connection size • Flush Flanged Seal 1 1/2-inch (40 mm), 2-inch (50 mm), 3-inch (80 mm) • Extended Flanged Seal 3-inch (80 mm), 4-inch (100 mm) • Inner Diaphragm Seal, Adapter Connection Type 1/2-inch (15 mm), 3/4-inch (20 mm), 1-inch (25 mm) • Inner Diaphragm Seal, Flange Connection...

 Open the catalog to page 3
EJXC40A Digital Remote Sensor-4

• Direct Mounted Diaphragm Seal System Direct Mounted Diaphragm Seal System consists of gauge pressure or differential pressure transmitter with a single direct mount diaphragm seal. Suitable for various kinds of pressure measurement. • : Applicable, -: Not applicable Applicable Products (Transmitter)11 • Differential Pressure Transmitter EJX110A: GS01C25B01-01EN EJA110E: GS01C31B01-01EN • Gauge Pressure Transmitter EJX530A: GS01C25F01-01EN EJA530E: GS01C31F01-01EN Process connection size • Flush Flanged Seal 1 1/2-inch (40 mm), 2-inch (50 mm), 3-inch (80 mm) • Extended Flanged Seal 3-inch (80...

 Open the catalog to page 4
EJXC40A Digital Remote Sensor-5

• Digital Remote Sensored Diaphragm Seal System Digital Remote Sensor (DRS) Transmitter connects two pressure sensors, high pressure side (master) and low pressure side (slave) in a remote location, with DRS dedicated communication cable to measure differential pressure. •: Applicable, S: Screw Mount Applicable Products (Transmitter)11 • Digital Remote Sensor Transmitter EJXC40A: GS 01C25W05-01EN Process connection size • Flush Flanged Seal 1 1/2-inch (40 mm), 2-inch (50 mm), 3-inch (80 mm) • Extended Flanged Seal 3-inch (80 mm), 4-inch (100 mm) • Flush Hygienic Seal (ISO Clamp Seal) ISO76.1,...

 Open the catalog to page 5
EJXC40A Digital Remote Sensor-6

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

 Open the catalog to page 6
EJXC40A Digital Remote Sensor-7

*1: C81FA, C81FD: Bundled capillary type (1 m separated) All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

 Open the catalog to page 7
EJXC40A Digital Remote Sensor-8

■ Direct Mount Flanged Diaphragm Seal Process connection style Raised face (RF) Flush type Process connection size (Process flange size) 3-inch (80 mm) 2-inch (50 mm) Raised face (RF) Flush type Raised face (RF) Extended type ■ Remote Mount Hygienic Diaphragm Seal Model C70SW Process connection style ISO clamp Flush type Process connection size ISO51 ISO76.1 ISO101.6 Capillary Connection Style Back of diaphragm seal unit ISO clamp Extended type Back of diaphragm seal unit ■ Direct Mount Hygienic Diaphragm Seal Model C30SW Process connection style ISO clamp Flush type Process connection size ISO51...

 Open the catalog to page 8
EJXC40A Digital Remote Sensor-9

□ SPAN AND RANGE LIMITS • Flange Mounted Diaphragm Seal System ■ Remote Mounted Seal, Direct Mounted Seal with Remote Seal (Combination type), or Compensation Capillary type • EJXC80A Differential pressure diaphragm seal system All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

 Open the catalog to page 9
EJXC40A Digital Remote Sensor-10

• EJXC81A Absolute pressure diaphragm seal system All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

 Open the catalog to page 10
EJXC40A Digital Remote Sensor-11

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

 Open the catalog to page 11
EJXC40A Digital Remote Sensor-12

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

 Open the catalog to page 12
EJXC40A Digital Remote Sensor-13

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

 Open the catalog to page 13
EJXC40A Digital Remote Sensor-14

Process temperature, Ambient temperature, and Working pressure ■ EJXC80A, EJAC80E Remote Mounted Seal, Direct Mounted Seal with Remote Seal (Combination type), or Compensation Capillary type Diaphragm Seal System Table 1-1a. Flange Mounted All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00 6: Temperature limit of cleansing process is up to 150°C (302°F) / max. 60 minutes *7: Temperature limit of cleansing process is up to 150°C (302°F) / max. 30 minutes *8: Applicable for both side remote mount flanged differential diaphragm seal or gauge

 Open the catalog to page 14

All YOKOGAWA Europe catalogs and technical brochures

  1. YS1500

    20  Pages

  2. UM33A/S006

    2  Pages

  3. YTA610

    20  Pages

  4. FA-M3V

    19  Pages

  5. RAMC

    24  Pages

  6. TB750G EXAxt

    3  Pages

  7. OX400

    2  Pages

  8. MW100

    5  Pages

  9. FieldMate

    5  Pages

  10. AMADAS

    4  Pages

  11. Exapilot

    5  Pages

  12. Exaquantum

    5  Pages

  13. BUCA150_E_050

    4  Pages

  14. BUAQ7280-01

    12  Pages

  15. BUXL120_E_030

    8  Pages

  16. BU7603_00E_060

    20  Pages

  17. BUAQ2200

    8  Pages

  18. Batch Control

    9  Pages

  19. ADMAG Series

    9  Pages

  20. Exaplog

    2  Pages

  21. AAASuite

    2  Pages

  22. InfoWell

    8  Pages

  23. VTSPortal

    2  Pages

  24. U33Q01A01-01E

    11  Pages

  25. BU33K01A01-50E

    11  Pages

  26. CENTUM.VP

    11  Pages

  27. ADMAG AXF

    2  Pages

  28. YTA series

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.