Compact and Noise-resistant Data Logger Bulletin XL120-E Data Logger ID : 01-000273 T M Size: 155 (W)155 (H)55 (D) mm Weight: Approx. 800 g (Without battery and rubber boot) To obtain IPv6 Ready Logo Phase-1 certification A world’s first in measuring instruments!
Open the catalog to page 12 External dimensions: 155 × 155 × 55(mm) Weight: Approx. 800 g Easy to carry The analog inputs are wired from the left, while the power and communication lines are wired from the right. This design makes Datum-Y a suitable option in a narrow space. Space Saving Resistance to impact is improved by the use of a rubber boot, which is removable. The dedicated lithium ion battery enables up to 7 hours of operation (in conditions recommended by Yokogawa). Wiring is easy, since the terminal block can be removed with a single action. Terminal block (for 16 channels) Built-in terminal screwdriver Built-in...
Open the catalog to page 2You can check measured data (binary) on Datum-Y right away. Overall trend and alarm output can be checked on the spot immediately after acquisition. While Datum-Y is logging data, you can display past data and current data in the logging review mode for comparison and identification of trend. (This function is available only when binary data is acquired.) 3 Variety of Functions Facilitate Measurement and Data Acquisition For communication with a PC via a USB cable. * Use a USB communication cable with a male Mini B connector. Spot Check of Acquired Data Alarm Function Trigger Function Screen...
Open the catalog to page 3FTP Server Function Built-in Modbus Protocol Capability Datum-Y employs Ethernet (10Base-T and 100Base-TX) standard protocols to provide the functions described below without using dedicated software. Furthermore, you can set user authentication for access to Datum-Y to prevent unauthorized access. Serial communication (RS-232, RS-485) can be performed using a dedicated protocol as well as Modbus RTU and Modbus ASCII protocols that are supported by Datum-Y’s standard capability. In addition to analog data (temperature and voltage), you can acquire the data of up to 32 measurement items of connected...
Open the catalog to page 4Composite Operation on Four Dedicated Channels during Real-time Measurement Main Function Measured Value Display at Two Points (A and B) with a Cursor Main Features Analysis Screen Display for Measured Data You can perform composite operations (e.g. log, , and ã _ , except for the four arithmetic operations) typical for a scientific electronic calculator on four dedicated arithmetic channels. You can create a calculation formula containing up to 16 terms comprising measured values and functions. ¡Supported environment: Windows 2000*, Windows XP* * Windows 2000 and Windows XP are registered trademarks...
Open the catalog to page 5Analog Input Section Calculation Floating unbalanced input, insulated between channels (Terminal "b" is shared by resistance temperature detector inputs.) 8 channels (XL121), 16 channels (XL122, XL124) Screw in (XL121, XL122), M3 screw (XL124) TC (thermocouple), RTD (resistance temperature detector), DCV (direct-current voltage) * RTD for Screw in type only ¡Input method ¡Number of inputs ¡Terminal shape ¡Input type Between 2 channels. (Measurement / calculation data / communication data, constant) Maximum value (MAX), minimum value (MIN), average value (AVE), peak value (P-P) and root-mean-square...
Open the catalog to page 6¡Storage data type Type Logging data Manual sampling data Alarm data Screen image data Setting data Log data Backup file Description Format Binary or ASCII ASCII ASCII BMP Binary ASCII Same format as logging data Measurement is performed at specified intervals in logging mode. / Instantaneous values (calculation data) are saved. Measurement is performed for all channels in free running mode when a certain key is operated. / Calculation data (instantaneous values) is saved. The same contents as the alarm summary are saved in logging mode each time an alarm occurs. The image data of the currently...
Open the catalog to page 7-D -F -H -R -S Model Suffix code 8ch, with Screw in type terminal block unit 16ch, wth Screw in type terminal block unit 16ch, with M3 screws type terminal block unit Power cord(UL/CSA Standard) Power cord(VDE Standard) Power cord(GB Standard) Power cord(AS Standard) Power cord(BS Standard) XL121 XL122 XL124 Specification Model number and suffix code Accessories Printer (97010) Lithium ion battery (94009) Digital I/O cable (91029) Stand (93039) * The AC adapter for printer (97010) is available as an option. * The unit stand cannot be stored. * Approx 200 (H) × 150 (W) mm, Approx 500g Carrying...
Open the catalog to page 820 Pages
2 Pages
20 Pages
19 Pages
24 Pages
12 Pages
135 Pages
3 Pages
2 Pages
3 Pages
8 Pages
4 Pages
7 Pages
8 Pages
2 Pages
4 Pages
4 Pages
17 Pages
5 Pages
5 Pages
4 Pages
5 Pages
5 Pages
4 Pages
12 Pages
8 Pages
20 Pages
8 Pages
8 Pages
3 Pages
3 Pages
7 Pages
9 Pages
5 Pages
9 Pages
2 Pages
2 Pages
86 Pages
3 Pages
10 Pages
2 Pages
2 Pages
2 Pages
9 Pages
2 Pages
2 Pages
8 Pages
3 Pages
3 Pages
2 Pages
4 Pages
2 Pages
11 Pages
11 Pages
8 Pages
27 Pages
26 Pages
12 Pages
3 Pages
4 Pages
11 Pages
5 Pages
2 Pages
7 Pages
28 Pages
12 Pages
19 Pages
14 Pages