
Compact and Noise-resistant Data Logger Data Logger A world's first in measuring To obtain IPv6 Ready Logo Phase-1 certification (Without battery and rubber boot) Yokogawa Meters & Instruments Corporation
Open the catalog to page 1Main Features » All channels adopt universal insulated inputs •Data can behaved at the maximum^speedoMO^ [•Comes standard with^ LA N port^^^^B : The temperature and voltage can be set independently for.each'channel.' : A wide view color TFT LCD makes it easy to read even'outdoors'l jj pi eli a b I y'lmeasu r e s te m per at urectiangesj _^j^H : En^loysTompact (la'sn'and SD.cards^ juSBThemory enables support tor a dataVopytS^^^^^^B : Also supports remote dalaTcquisilionl ^^MB^^^^^B Application Examples Testing and evaluating product temperatures using a thermostatic.chamber Detecting and analyzing...
Open the catalog to page 2Variety of Functions Facilitate Measurement and Data Acquisition Spot Check of Acquired Data Trigger Function You can check measured data (binary) on Datum-Y right away. Overall trend and alarm output can be checked on the spot immediately after acquisition. While Datum-Y is logging data, you can display past data and current data in the logging review mode for comparison and identification of trend. (This function is available only when binary data is acquired.) You can use the pretrigger/trigger delay function, which is convenient when you detect and analyze the cause of an error. You can start...
Open the catalog to page 3Remote Data Acquisition Using Web Monitoring, FTP, and E-mail Delivery LAN Datum-Y employs Ethernet (10Base-T and 100Base-TX) standard protocols to provide the functions described below without using dedicated software. Furthermore, you can set user authentication for access to Datum-Y to prevent unauthorized access. E-mail Delivery Function Explorer*1 You can easily monitor the Datum-Y screens with the Internet Web browser (Screen display can be updated every 5, 10, or 30 seconds automatically, or manually). You can use Operator Page*2 to remotely operate Datum-Y, except for turning the power...
Open the catalog to page 4Application Software “Datum-LOGGER” allows you to connect up to ten Datum-Ys to analyze and process data after you perform real-time measurement and acquire data with a PC. Main Features ¡ Real-time measurement at the maximum speed of 1 second ¡ Zooming to analyze acquired data in the waveform view ¡ A variety of data saving functions available (selective and partial saving) Composite Operation on Four Dedicated Channels during Real-time Measurement You can perform composite operations (e.g. log, ⌺, _ and √ , except for the four arithmetic operations) typical for a scientific electronic calculator...
Open the catalog to page 5Specifications Analog Input Section Digital Input Section : Floating unbalanced input, insulated between channels (Terminal "b" is shared by resistance temperature detector inputs.) ¡Number of inputs : 8 channels (XL121), 16 channels (XL122, XL124) ¡Terminal shape : Screw in (XL121, XL122), M3 screw (XL124) : TC (thermocouple), RTD (resistance temperature detector), ¡Input type DCV (direct-current voltage) * RTD for Screw in type only ¡Range and measurement range : ¡Input method Reference operating conditions: Temperature (23±2˚C), humidity (55±10%RH), power supply voltage (100 to 240 VAC), power...
Open the catalog to page 6¡Storage data type Type Logging data Measurement is performed at specified intervals in logging mode. / Instantaneous values (calculation data) are saved. Manual sampling data Measurement is performed for all channels in free running mode when a certain key is operated. / Calculation data (instantaneous values) is saved. Alarm data The same contents as the alarm summary are saved in logging mode each time an alarm occurs. Screen image data The image data of the currently displayed screen is saved when a certain key is operated. Setting data The settings made to the instrument are saved when a...
Open the catalog to page 7General Specifications ¡Location for use: Indoor, at an altitude of 2000 meters or less ¡Operating temperature/humidity range: 0 to 50˚C (0 to 40˚C if a battery is used), 5 to 85%RH (no condensation) ¡Storage temperature/humidity range: -20 to 60˚C, 90%RH or less (no condensation) ¡Insulation resistance • Between each input terminal and frame : 20 MΩ or higher (500 VDC) • Between input terminals (except for terminal b) : 20 MΩ or higher (100 VDC) • Between each input terminal and digital input/output : 20 MΩ or higher (100 VDC) ¡Withstanding voltage • Between each input terminal and frame : 350...
Open the catalog to page 820 Pages
2 Pages
20 Pages
19 Pages
24 Pages
12 Pages
135 Pages
3 Pages
2 Pages
3 Pages
8 Pages
4 Pages
7 Pages
8 Pages
2 Pages
4 Pages
4 Pages
17 Pages
5 Pages
5 Pages
4 Pages
5 Pages
5 Pages
4 Pages
12 Pages
20 Pages
8 Pages
8 Pages
3 Pages
3 Pages
7 Pages
9 Pages
5 Pages
9 Pages
2 Pages
2 Pages
86 Pages
3 Pages
10 Pages
2 Pages
2 Pages
2 Pages
9 Pages
2 Pages
2 Pages
8 Pages
3 Pages
3 Pages
2 Pages
4 Pages
2 Pages
11 Pages
11 Pages
8 Pages
27 Pages
26 Pages
12 Pages
3 Pages
4 Pages
11 Pages
5 Pages
2 Pages
7 Pages
28 Pages
12 Pages
19 Pages
14 Pages